Voltammetric determination of nitric oxide using a glassy carbon electrode modified with a nanohybrid consisting of myoglobin, gold nanorods, and reduced graphene oxide

被引:0
|
作者
Ab Rahman Marlinda
Alagarsamy Pandikumar
Subramaniam Jayabal
Norazriena Yusoff
Abu Bakar Suriani
Nay Ming Huang
机构
[1] University of Malaya,Low Dimensional Materials Research Centre, Department of Physics, Faculty of Science
[2] SRM University,Research Institute & Department of Chemistry
[3] University Pendidikan Sultan Idris,Nanotechnology Research Centre, Faculty of Science and Mathematics
来源
Microchimica Acta | 2016年 / 183卷
关键词
Electroanalysis; Biosensor; Nanocomposite; Localized surface plasmon resonance; LSPR; Linear sweep voltammetry; X-ray diffractometry; X-ray photoelectron spectroscopy; Capillary dilatator;
D O I
暂无
中图分类号
学科分类号
摘要
Myoglobin-modified gold nanorods incorporating reduced graphene oxide (rGO) were fabricated and deposited on a glassy carbon electrode (GCE) to obtain a sensor for nitric oxide (NO). The Mb-AuNR/rGO nanohybrid showed a transverse localized surface plasmon resonance (LSPR) band with a peak at 508 nm, and a longitudinal LSPR band at 724 nm. The AuNRs have an average length of 38 ± 3 nm and a width of 11 ± 1 nm. The GCE modified with the nanohybrid is shown to be a viable sensor for the determination of NO by linear sweep voltammetry. Its electrocatalytic response toward the oxidation of NO is distinctly enhanced compared to other electrodes. The sensor, best operated at a working voltage of 0.85 V (vs. SCE), showed two linear response ranges (from 10 to100 μM, and from 100 to 1000 μM), with a detection limit of 5.5 μM. Furthermore, it exhibits excellent selectivity for NO over common interferents such as NaNO3, and also over electroactive species such as ascorbate, dopamine, glucose, and uric acid. These properties make it a promising tool for the detection of NO in situations such as capillary and pulmonary hypertension and embolism, and during vasodilation.
引用
收藏
页码:3077 / 3085
页数:8
相关论文
共 50 条
  • [31] Ultrasensitive aptamer-based on-off assay for lysozyme using a glassy carbon electrode modified with gold nanoparticles and electrochemically reduced graphene oxide
    Shamsipur, Mojtaba
    Farzin, Leila
    Tabrizi, Mahmoud Amouzadeh
    MICROCHIMICA ACTA, 2016, 183 (10) : 2733 - 2743
  • [32] Electrochemical Determination of Nitrite Using a Reduced Graphene Oxide-Multiwalled Carbon Nanotube-Modified Glassy Carbon Electrode
    Deng, Keqin
    Zhou, Jianhong
    Huang, Haowen
    Ling, Yulin
    Li, Chunxiang
    ANALYTICAL LETTERS, 2016, 49 (18) : 2917 - 2930
  • [33] Simultaneous determination of dopamine, uric acid and ascorbic acid using a glassy carbon electrode modified with reduced graphene oxide
    Wang, Huiwen
    Ren, Fangfang
    Wang, Caiqin
    Yang, Beibei
    Bin, Duan
    Zhang, Ke
    Du, Yukou
    RSC ADVANCES, 2014, 4 (51) : 26895 - 26901
  • [34] A Laser Reduced Graphene Oxide Grid Electrode for the Voltammetric Determination of Carbaryl
    Saqib, Muhammad
    Dorozhko, Elena V.
    Barek, Jiri
    Vyskocil, Vlastimil
    Korotkova, Elena I.
    Shabalina, Anastasiia V.
    MOLECULES, 2021, 26 (16):
  • [35] Electrochemical Determination of Dopamine Using a Poly(3,4-Ethylenedioxythiophene)-Reduced Graphene Oxide-Modified Glassy Carbon Electrode
    Cogal, Sadik
    ANALYTICAL LETTERS, 2018, 51 (11) : 1666 - 1679
  • [36] Electrochemical determination of tryptophan using a glassy carbon electrode modified with flower-like structured nanocomposite consisting of reduced graphene oxide and SnO2
    Haldorai, Yuvaraj
    Yeon, Sun-Hwa
    Huh, Yun Suk
    Han, Young-Kyu
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 239 : 1221 - 1230
  • [37] Voltammetric Determination of Rhodamine B Using a ZIF-67/Reduced Graphene Oxide Modified Electrode
    Huynh Truong Ngo
    Vo Thang Nguyen
    Tran Duc Manh
    Tran Thanh Tam Toan
    Nguyen Thi Minh Triet
    Nguyen Thanh Binh
    Nguyen Thi Vuong Hoan
    Tran Vinh Thien
    Dinh Quang Khieu
    JOURNAL OF NANOMATERIALS, 2020, 2020
  • [38] Electrochemical sensing of phenacetin on electrochemically reduced graphene oxide modified glassy carbon electrode
    Meng, Xiao-Tong
    Zhu, De-Jing
    Jiang, Yu-Hang
    Cao, Yue
    Si, Wei-Meng
    Cao, Jun
    Li, Qiu-Hong
    Li, Jiao
    Lei, Wu
    NEW CARBON MATERIALS, 2022, 37 (04) : 764 - 771
  • [39] Voltammetric Determination of Tramadol Using a Hierarchical Graphene Oxide Nanoplatelets Modified Electrode
    Saichanapan, Jenjira
    Promsuwan, Kiattisak
    Saisahas, Kasrin
    Soleh, Asamee
    Chang, Kah Haw
    Abdullah, Ahmad Fahmi Lim
    Limbut, Warakorn
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2021, 168 (11)
  • [40] Electrochemical Determination of Diclofenac Sodium in Pharmaceutical Sample Using Copper Nanoparticles/Reduced Graphene Oxide Modified Glassy Carbon Electrode
    Yu, Haichi
    Jiao, Jianhang
    Li, Qiuju
    Li, Yingzhi
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2021, 16 (10): : 1 - 12