Use of Amplatzer Vascular Plug (AVP) in emergency embolisation: Preliminary experience and review of literature

被引:21
作者
Mangini M. [1 ]
Laganà D. [1 ]
Fontana F. [1 ]
Ianniello A. [1 ]
Nicotera P. [1 ]
Petullà M. [1 ]
Carrafiello G. [1 ]
Fugazzola C. [1 ]
机构
[1] Vascular and Interventional Radiology, Department of Radiology, University of Insubria, 1100 Varese, Viale Borri
关键词
Embolisation; Emergency; Interventional radiology; Vascular plug;
D O I
10.1007/s10140-007-0696-8
中图分类号
学科分类号
摘要
Amplatzer Vascular Plug (AVP) is a device recently proposed for extra-cardiac procedures such as arterial and venous embolisation. In this paper, we assess the usefulness of AVP in emergency embolisation presenting our preliminary experience and reviewing the Literature. During the last year, we selected 31 patients for embolisation using AVP. The following nine procedures were performed in emergency (8 males, mean 72.4 years, range 57-85): four ruptured abdominal aortic aneurysm, one traumatic hepatic pseudoaneurysm with arterio-portal fistula, one carotid pseudoaneurysm due to neoplastic erosion, one renal tumor with active bleeding, one ruptured isolated iliac aneurysm and one ruptured hypogastric aneurysm. We used a total of 13 AVPs. The follow-up was carried out by computed tomography angiography (CTA) and/or contrast-enhanced ultrasound (CEUS), 3 months after the procedure and then every 3 months. We obtained immediate technical success in all nine cases. No rupture or dissection of the treated arteries occurred. We observed only an asymptomatic spasm. During a mean follow-up of 5.3 months (range 3-12 months), CTA and/or CEUS showed complete occlusion of the treated arteries. The AVP is useful in some emergency settings. In the authors' experience, the device allows precise, controlled release and can be deployed to the target more rapidly than other traditional methods. The device cannot be used in all patients due to limited ability to negotiate tortuous vessels and limited size availability. In our institution, the AVP is less expensive than alternatives. In our experience and as reported in the early literature, the device is easy to use, versatile, and achieved a high technical success rate. Further studies may confirm the effectiveness and demonstrate additional indications. © 2007 Am Soc Emergency Radiol.
引用
收藏
页码:153 / 160
页数:7
相关论文
共 25 条
[1]  
Wang J.K., Tsai S.K., Wu M.H., Lin M.T., Lue H.C., Short- and intermediate-term results of transcatheter closure of atrial septal defect with the Amplatzer Septal Occluder, Am Heart J, 148, pp. 511-517, (2004)
[2]  
Santoro G., Bigazzi M.C., Palladino M.T., Russo M.G., Carrozza M., Calabro R., Comparison of percutaneous closure of large patent ductus arteriosus by multiple coils versus the Amplatzer duct occluder device, Am J Cardiol, 94, pp. 252-255, (2004)
[3]  
Kessler J., Trerotola S.O., Use of the Amplatzer Vascular Plug for embolization of a Retroperitoneal Shunt during Transjugular intrahepatic portosystemic shunt creation for gastric variceal bleeding, JVIR, 17, pp. 135-140, (2006)
[4]  
Cil B., Canyigit M., Ozkan O.S., Pamuk G.A., Dogan R., Bilateral multiple pulmonary arteriovenous malformations: Endovascular treatment with the Amplatzer vascular plug, JVIR, 17, pp. 141-145, (2006)
[5]  
Hoit D.A., Schirmer C.M., Malek A.M., Use of the Amplatzer vascular plug as an anchoring scaffold for coil-mediated parent vessel occlusion: Technical case report, Neurosurgery, 59, pp. 171-172, (2006)
[6]  
Dorenberg E.J., Hafsahl G., Andersen R., Krohg-Sorensen K., Recurrent rupture of a hypogastric aneurysm caused by spontaneous recanalization of an Amplatzer vascular plug, J Vasc Interv Radiol, 17, pp. 1037-1041, (2006)
[7]  
Rossi M., Rebonato A., Greco L., Stefanini G., Citone M., Speranza A., Et al., A new device for vascular embolization: Report on case of two pulmonary arteriovenous fistulas embolization using the amplatzer vascular plug, Cardiovasc Intervent Radiol, 29, pp. 902-906, (2006)
[8]  
Hoppe H., Hohenwalter E.J., Kaufman J.A., Petersen B., Percutaneous treatment of aberrant right subclavian artery aneurysm with use of the Amplatzer septal occluder, J Vasc Interv Radiol, 17, pp. 889-894, (2006)
[9]  
Beck A., Dagan T., Matitiau A., Bruckheimer E., Transcatheter closure of pulmonary arteriovenous malformations with amplatzer devices, Catheter Cardiovasc Interv, 67, pp. 932-937, (2006)
[10]  
Mylonas I., Sakata Y., Salinger M.H., Feldman T., Successful closure of a giant true saphenous vein graft aneurysm using the Amplatzer vascular plug, Catheter Cardiovasc Interv, 67, pp. 611-616, (2006)