Polarisation changes in guided infrared thermography using silver halide poly-crystalline mid-infrared fibre bundle

被引:0
|
作者
Sarah K. Markham
Aladin Mani
Elena A. Korsakova
Aleksandr S. Korsakov
Liya V. Zhukova
Joanna Bauer
Christophe Silien
Syed A. M. Tofail
机构
[1] University of Limerick,Department of Physics and Bernal Institute
[2] Ural Federal University named after the first President of Russia B. N. Yeltsin,Department of Biomedical Engineering, Faculty of Fundamental Problems of Technology
[3] Wroclaw University of Science and Technology,undefined
关键词
Infrared thermography; Optical polarisation; Silver halide poly-crystalline; Broadband mid-infrared fibre bundle; Personalised medicine;
D O I
暂无
中图分类号
学科分类号
摘要
Broadband mid-infrared (B-MIR) thermography using fibre optic waveguides can be critical in real-time imaging in harsh environments such as additive manufacturing, personalised medical diagnosis and therapy. We investigate the polarisation effect on thermal measurements through poly-crystalline fibre bundle employing a simple broadband cross-polarisation configuration experimental set-up. Silver halide poly-crystalline fibres AgCl1−xBrx (0 ≤ x≤1) (AgClBr-PolyC) have very wide transmission bandwidth spanning over the spectral range from 1 µm up to 31 µm FWHM. Moreover, they are non-toxic, non-hygroscopic, with relatively good flexibility, which make them very adequate for spectroscopic and thermal measurements in medical and clinical fields. In this study, we used a fibre bundle composed of seven single AgClBr-PolyC fibres, each with a core diameter of about 300 µm, inserted between two broadband MIR polarisers. A silicon carbide filament source was placed at the entrance of the fibre bundle, while a FLIR thermal camera with a close-up lens was employed to measure the spatial temperature distribution over the fibre-bundle end. Indeed, polarisation dependence of temperature measurements has been clearly observed in which the orientation of temperature extrema (minima and maxima) vary from one fibre to another within the bundle. Moreover, these observations have enabled the classification of AgClBr-PolyC fibres following their polarisation sensitivities by which some fibres are relatively highly sensitive to polarisation with polarisation temperature difference (PTD) that can reach 22.1 ± 2.8 °C, whereas some others show very low PTD values down to 3.1 ± 2.8 °C. Many applications can readily be found based on the advantages of both extreme cases.
引用
收藏
页码:1115 / 1122
页数:7
相关论文
共 50 条
  • [31] Real-time bioprocess monitoring using a mid-infrared fibre-optic sensor
    Alimagham, Farah
    Winterburn, James
    Dolman, Ben
    Domingues, Patricia Maia
    Everest, Francesca
    Platkov, Max
    Basov, Svetlana
    Izakson, Gregory
    Katzir, Abraham
    Elliott, Stephen R.
    Hutter, Tanya
    BIOCHEMICAL ENGINEERING JOURNAL, 2021, 167
  • [32] Prospective on using fibre mid-infrared supercontinuum laser sources for in vivo spectral discrimination of disease
    Seddon, Angela B.
    Napier, Bruce
    Lindsay, Ian
    Lamrini, Samir
    Moselund, Peter M.
    Stone, Nicholas
    Bang, Ole
    Farries, Mark
    ANALYST, 2018, 143 (24) : 5874 - 5887
  • [33] Detection of counterfeit Scotch whisky samples using mid-infrared spectrometry with an attenuated total reflectance probe incorporating polycrystalline silver halide fibres
    McIntyre, Allyson C.
    Bilyk, Madeleine L.
    Nordon, Alison
    Colquhoun, Gary
    Littlejohn, David
    ANALYTICA CHIMICA ACTA, 2011, 690 (02) : 228 - 233
  • [34] Surface-enhanced optical-mid-infrared photothermal microscopy using shortened colloidal silver nanowires: a noble approach for mid-infrared surface sensing
    Baden, Naoki
    Watanabe, Hirohmi
    Aoyagi, Masaru
    Ujii, Hiroshi
    Fujita, Yasuhiko
    NANOSCALE HORIZONS, 2024, 9 (08) : 1311 - 1317
  • [35] Temperature-Induced Molecular Structural Changes of Linear Poly(ethylene imine) in Water Studied by Mid-Infrared and Near-Infrared Spectroscopies
    Kakuda, Hiroyuki
    Okada, Tetsuo
    Hasegawa, Takeshi
    JOURNAL OF PHYSICAL CHEMISTRY B, 2009, 113 (42): : 13910 - 13916
  • [36] Using mid-infrared glucose absorption peak changes for high-precision glucose detection
    Kim, Do-Hyun
    Ilev, Ilko K.
    Kang, Jin U.
    2007 IEEE LEOS ANNUAL MEETING CONFERENCE PROCEEDINGS, VOLS 1 AND 2, 2007, : 226 - +
  • [37] Monitoring of harmful gaseous emissions from land transport vehicles using a mid-infrared optical fibre sensor
    Mulrooney, Jim
    Clifford, John
    Fitzpatrick, Colin
    Lewis, Elfed
    PHOTONICS IN THE AUTOMOBILE II, 2006, 6198
  • [38] Detection of carbon dioxide emissions from a diesel engine using a mid-infrared optical fibre based sensor
    Mulrooney, Jim
    Clifford, John
    Fitzpatrick, Colin
    Lewis, Elfed
    SENSORS AND ACTUATORS A-PHYSICAL, 2007, 136 (01) : 104 - 110
  • [39] Mid-infrared spectroscopic detection of trace gases using guided-wave difference-frequency generation
    Petrov, KP
    Ryan, AT
    Patterson, TL
    Huang, L
    Field, SJ
    Bamford, DJ
    APPLIED PHYSICS B-LASERS AND OPTICS, 1998, 67 (03): : 357 - 361
  • [40] Mid-infrared chemical imaging of intracellular tau fibrils using fluorescence-guided computational photothermal microscopy
    Jian Zhao
    Lulu Jiang
    Alex Matlock
    Yihong Xu
    Jiabei Zhu
    Hongbo Zhu
    Lei Tian
    Benjamin Wolozin
    Ji-Xin Cheng
    Light: Science & Applications, 12