Polarisation changes in guided infrared thermography using silver halide poly-crystalline mid-infrared fibre bundle

被引:0
|
作者
Sarah K. Markham
Aladin Mani
Elena A. Korsakova
Aleksandr S. Korsakov
Liya V. Zhukova
Joanna Bauer
Christophe Silien
Syed A. M. Tofail
机构
[1] University of Limerick,Department of Physics and Bernal Institute
[2] Ural Federal University named after the first President of Russia B. N. Yeltsin,Department of Biomedical Engineering, Faculty of Fundamental Problems of Technology
[3] Wroclaw University of Science and Technology,undefined
关键词
Infrared thermography; Optical polarisation; Silver halide poly-crystalline; Broadband mid-infrared fibre bundle; Personalised medicine;
D O I
暂无
中图分类号
学科分类号
摘要
Broadband mid-infrared (B-MIR) thermography using fibre optic waveguides can be critical in real-time imaging in harsh environments such as additive manufacturing, personalised medical diagnosis and therapy. We investigate the polarisation effect on thermal measurements through poly-crystalline fibre bundle employing a simple broadband cross-polarisation configuration experimental set-up. Silver halide poly-crystalline fibres AgCl1−xBrx (0 ≤ x≤1) (AgClBr-PolyC) have very wide transmission bandwidth spanning over the spectral range from 1 µm up to 31 µm FWHM. Moreover, they are non-toxic, non-hygroscopic, with relatively good flexibility, which make them very adequate for spectroscopic and thermal measurements in medical and clinical fields. In this study, we used a fibre bundle composed of seven single AgClBr-PolyC fibres, each with a core diameter of about 300 µm, inserted between two broadband MIR polarisers. A silicon carbide filament source was placed at the entrance of the fibre bundle, while a FLIR thermal camera with a close-up lens was employed to measure the spatial temperature distribution over the fibre-bundle end. Indeed, polarisation dependence of temperature measurements has been clearly observed in which the orientation of temperature extrema (minima and maxima) vary from one fibre to another within the bundle. Moreover, these observations have enabled the classification of AgClBr-PolyC fibres following their polarisation sensitivities by which some fibres are relatively highly sensitive to polarisation with polarisation temperature difference (PTD) that can reach 22.1 ± 2.8 °C, whereas some others show very low PTD values down to 3.1 ± 2.8 °C. Many applications can readily be found based on the advantages of both extreme cases.
引用
收藏
页码:1115 / 1122
页数:7
相关论文
共 50 条
  • [21] Synchronously pumped mid-infrared OPOs using silver gallium sulphide
    McEwan, KJ
    Terry, JAC
    Payne, J
    SOLID STATE LASERS VII, 1998, 3265 : 60 - 69
  • [22] Chemically tapered silver halide fibers: An approach for increasing the sensitivity of mid-infrared evanescent wave sensors
    Karlowatz, M
    Kraft, M
    Eitenberger, E
    Mizaikoff, B
    Katzir, A
    APPLIED SPECTROSCOPY, 2000, 54 (11) : 1629 - 1633
  • [23] Single mode mid-infrared silver halide asymmetric flat waveguide obtained from crystal extrusion
    Grille, Romain
    Martin, Guillermo
    Labadie, Lucas
    Arezki, Brahim
    Kern, Pierre
    Lewi, Tomer
    Tsun, A.
    Katzir, Abraham
    OPTICS EXPRESS, 2009, 17 (15): : 12516 - 12522
  • [24] Photochemical 2D-structuring mid-infrared flexible plates made of silver halide polycrystals
    Korsakov, V. S.
    Korsakova, E. A.
    Pakhomenko, O. N.
    Korsakov, M. S.
    Zhukova, L. V.
    INTERNATIONAL CONFERENCE LASER OPTICS 2020 (ICLO 2020), 2020,
  • [25] A novel laser angioplasty guided hollow fiber using mid-infrared laser
    Yoshihashi-Suzuki, Sachiko
    Yamada, Shinya
    Sato, Izuru
    Awazu, Kunio
    OPTICAL FIBERS AND SENSORS FOR MEDICAL DIAGNOSTICS AND TREATMENT APPLICATIONS VI, 2006, 6083
  • [26] Mid-infrared plasmonic filter arrays using nanoholes in gold and silver films
    Wenger, Tobias
    Muller, Richard E.
    Wilson, Daniel W.
    Soibel, Alexander
    OPTICS LETTERS, 2023, 48 (15) : 3925 - 3928
  • [27] Beam homogenizer for infrared hollow waveguides using silver-halide fibre tip
    Matsuura, Y
    Miyagi, M
    German, A
    Nagli, L
    Katzir, A
    BIOMEDICAL SYSTEMS AND TECHNOLOGIES II, PROCEEDINGS OF, 1998, 3199 : 70 - 74
  • [28] Mid-infrared evanescent field sensors based on quantum cascade lasers and planar silver halide fibers.
    Charlton, C
    Katzir, A
    Muller, A
    Beck, M
    Hofstetter, D
    Faist, J
    Mizaikoff, B
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2003, 226 : U106 - U106
  • [29] Long-wavelength mid-infrared reflectors using guided-mode resonance
    Lai, Kou-Wei
    Lin, Sheng-Di
    Li, Zong-Lin
    Wang, Chi-Cheng
    APPLIED OPTICS, 2013, 52 (28) : 6906 - 6909
  • [30] Real-time bioprocess monitoring using a mid-infrared fibre-optic sensor
    Alimagham, Farah
    Winterburn, James
    Dolman, Ben
    Domingues, Patrícia Maia
    Everest, Francesca
    Platkov, Max
    Basov, Svetlana
    Izakson, Gregory
    Katzir, Abraham
    Elliott, Stephen R.
    Hutter, Tanya
    Biochemical Engineering Journal, 2021, 167