Effects of Un-transposed UHV transmission line on fault analysis of power systems

被引:0
|
作者
Wang A. [1 ]
Chen Q. [1 ]
Zhou Z. [1 ]
机构
[1] School of Electrical Engineering, Shandong University
关键词
EMTPE; Fault calculation; Simulation; Un-transposed UHV transmission line;
D O I
10.1007/s12209-008-0042-6
中图分类号
学科分类号
摘要
The conventional fault analysis method based on symmetrical components supposes that the three-phase parameters of un-transposed transmission line are symmetrical in case of fault. The errors caused by the method with the symmetrical distributed parameter circuit model as the equivalent circuit of the un-transposed ultra high voltage (UHV) transmission line were studied under both normal operation and fault,and the corresponding problems arising were pointed out. By contrast with electromagnetic transient and power electronics (EMTPE) simulation results with the asymmetrical distributed parameter circuit model of un-transposed line, it is shown that the conventional method cannot show the existence of negative and zero sequences before fault happening and there are many errors on voltage and current after fault happening which are different with fault types. The error ranges of voltage and current are 2.13%-81.13% and -7.82%- -86.15%, respectively.
引用
收藏
页码:231 / 234
页数:3
相关论文
共 50 条
  • [11] On-line analysis of fault events in power transmission systems using SOE, fuzzy logic and expert systems
    1600, Revista Tecnica de la Facultad de Ingeniera, Apartado Postal 10 482, Maracaibo, 4002 A, Venezuela (36):
  • [12] On-line analysis of fault events in power transmission systems using SOE, fuzzy logic and expert systems
    Llano, Luis E.
    Moreno, Julian
    REVISTA TECNICA DE LA FACULTAD DE INGENIERIA UNIVERSIDAD DEL ZULIA, 2013, 36 (02): : 174 - 182
  • [13] New algorithm for the fault analysis on barrel transposed high-phase-order power systems
    Bhat, B.K.
    Journal of the Institution of Engineers (India): Electrical Engineering Division, 1995, 76 : 7 - 13
  • [14] AURORAL EFFECTS ON POWER TRANSMISSION-LINE SYSTEMS
    AKASOFU, SI
    ASPNES, JD
    NATURE, 1982, 295 (5845) : 136 - 137
  • [15] A Novel Reactive Power Compensation Scheme of UHV AC Transmission Line
    Zhang, Jingchao
    Chen, Zhuoya
    Gao, Kun
    Yan, Anhe
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 3238 - +
  • [16] Consistency analysis between the electric field and audible noise caused by UHV test line and UHV transmission line
    Lu, Yao
    Gan, Zhe-Yuan
    Chen, Yu-Chao
    Li, Ni
    Zha, Xian-Guang
    Gaodianya Jishu/High Voltage Engineering, 2011, 37 (02): : 354 - 360
  • [17] Analysis on structural reliability of multi-circuit tower for EHV and UHV AC power transmission line
    Gao, Yan
    Yang, Jingbo
    Han, Junke
    Dianwang Jishu/Power System Technology, 2010, 34 (09): : 181 - 184
  • [18] Computation of Audible Noise from a 1200 kV UHV Power Transmission Line
    Kumar, K. Bharath
    Thomas, M. Joy
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2016, 23 (02) : 974 - 978
  • [19] The influence of the UHV transmission line to the TTCs between provincial power grids in CCG
    Yang, Huimin
    Wen, Jinyu
    Jiang, Lin
    Cheng, Shijie
    2008 THIRD INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES, VOLS 1-6, 2008, : 1412 - 1415
  • [20] Application of grey relational analysis to fault type identification on power transmission line
    Zhijun, Long
    PROCEEDINGS OF 2007 IEEE INTERNATIONAL CONFERENCE ON GREY SYSTEMS AND INTELLIGENT SERVICES, VOLS 1 AND 2, 2007, : 167 - 171