Frugal innovation in cardiac surgery

被引:9
作者
Valiathan M.V.S. [1 ]
机构
[1] School of Life Sciences, Dr TMA Pai Planetarium Complex, Manipal Academy of Higher Education (MAHE), Manipal
关键词
Frugal innovation; Haynes; 25; alloy; Tilting disc valve;
D O I
10.1007/s12055-018-0652-0
中图分类号
学科分类号
摘要
The development of a tilting disc heart valve in full compliance with ISO standards and affordable for low-income patients in India was undertaken in the early 1980s at the Sree Chitra Institute, Trivandrum. The constraint on resources and emphasis on self-reliance made frugal innovation obligatory for valve development. After the failure of three initial models, the fourth model succeeded and was used clinically in December 1990. Equally successful in a multi-centric trial in India, it has been implanted in over 100,000 patients to date. In overcoming problems in relation to the choice of materials and tests for performance during valve development, several innovations were employed in the low-resource setting of Chitra Institute, which anticipated the advent of “Frugal Innovation” by three decades. © 2018, Indian Association of Cardiovascular-Thoracic Surgeons.
引用
收藏
页码:439 / 448
页数:9
相关论文
共 11 条
  • [1] Radjou N., Prabhu J., Frugal Innovation: How to Do Better with Less, (2015)
  • [2] Radjou N., Prabhu J., Frugal Innovation: How to Do Better with Less. Econ Hachette India, (2015)
  • [3] Datta P., Mukhopadhyay I., Selvaraj S., Medical Devices Manufacturing Industry in India. ISID-PHFI Collaborative Research Programme Working Paper Series 02, (2013)
  • [4] Mahal A., Karan A.K., Diffusion of medical technology: medical devices in India, Expert Rev Med Devices, 6, pp. 197-205, (2009)
  • [5] Valiathan M.S., Bhuvaneshwar G.S., Cardiac valvular prosthesis: an indigenous approach to development, Indian Heart J, 34, pp. 387-390, (1982)
  • [6] Bhuvaneshwar G.S., Venkatesan V.S., Pattankar V.L., Kartha C.C., Lal A.V., Valiathan M.S., Development of textile fabrics for surgical applications, Indian J Med Res, 74, pp. 580-585, (1981)
  • [7] Bhuvaneshwar G.S., Ramani A.V., Valiathan M.S., A tilting disc valve - component materials and hydraulic function, Bull Mater Sci, 3, pp. 111-121, (1983)
  • [8] Bhuvaneshwar G.S., Muraleedharan C.V., Lal G.A.V., Ramani A.V., Valiathan M.S., Synthetic sapphire as an artificial heart valve occluder- promise and problems, Trans Indian Ceram Soc, 50, pp. 87-92, (1991)
  • [9] Bhuvaneshwar G.S., Muraleedharan C.V., Vijayan G.A., Kumar R.S., Valiathan M.S., Development of the Chitra tilting disc heart valve prosthesis, J Heart Valve Dis, 5, pp. 448-458, (1996)
  • [10] Kumar R.S., Bhuvaneshwar G.S., Magotra R., Et al., Chitra heart valve: results of a multi centric study, J Heart Valve Dis, 10, pp. 619-627, (2001)