Displacement detection with sub-pixel accuracy and high spatial resolution using deep learning

被引:4
作者
Yamamoto, Mariko [1 ]
Yoshizawa, Shin [1 ]
机构
[1] Tohoku Univ, Grad Sch Engn, Aoba Ku, 6-6-05 Aoba, Sendai, Miyagi 9808579, Japan
关键词
Displacement detection; Deep learning; Spatial resolution; Detection accuracy; HIFU;
D O I
10.1007/s10396-021-01162-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose The purpose of this study was to detect two dimensional and sub-pixel displacement with high spatial resolution using an ultrasonic diagnostic apparatus. Conventional displacement detection methods assume neighborhood uniformity and cannot achieve both high spatial resolution and sub-pixel displacement detection. Methods A deep-learning network that utilizes ultrasound images and output displacement distribution was developed. The network structure was constructed by modifying FlowNet2, a widely used network for optical flow estimation, and a training dataset was developed using ultrasound image simulation. Detection accuracy and spatial resolution were evaluated via simulated ultrasound images, and the clinical usefulness was evaluated with ultrasound images of the liver exposed to high-intensity-focused ultrasound (HIFU). These results were compared to the Lucas-Kanade method, a conventional sub-pixel displacement detection method. Results For a displacement within +/- 40 mu m (+/- 0.6 pixels), a pixel size of 67 mu m, and signal noise of 1%, the accuracy was above 0.5 mu m and 0.2 mu m, the precision was above 0.4 mu m and 0.3 mu m, and the spatial resolution was 1.1 mm and 0.8 mm for the lateral and axial displacements, respectively. These improvements were also observed in the experimental data. Visualization of the lateral displacement distribution, which determines the edge of the treated lesion using HIFU, was also realized. Conclusion Two-dimensional and sub-pixel displacement detection with high spatial resolution was realized using a deep-learning methodology. The proposed method enabled the monitoring of small and local tissue deformations induced by HIFU exposure.
引用
收藏
页码:3 / 15
页数:13
相关论文
共 23 条
[1]   COMPOUND SCANNING WITH AN ELECTRICALLY STEERED BEAM [J].
BERSON, M ;
RONCIN, A ;
POURCELOT, L .
ULTRASONIC IMAGING, 1981, 3 (03) :303-308
[2]   A Pilot Study on Convolutional Neural Networks for Motion Estimation From Ultrasound Images [J].
Evain, Ewan ;
Faraz, Khuram ;
Grenier, Thomas ;
Garcia, Damien ;
De Craene, Mathieu ;
Bernard, Olivier .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2020, 67 (12) :2565-2573
[3]   Learning the implicit strain reconstruction in ultrasound elastography using privileged information [J].
Gao, Zhifan ;
Wu, Sitong ;
Liu, Zhi ;
Luo, Jianwen ;
Zhange, Heye ;
Gong, Mingming ;
Li, Shuo .
MEDICAL IMAGE ANALYSIS, 2019, 58
[4]  
Giomore, 2008, PRACTIVAL GAMMA RAY, DOI [10.1002/9780470861981, DOI 10.1002/9780470861981]
[5]  
Goodfellow I, 2016, ADAPT COMPUT MACH LE, P1
[6]   FlowNet 2.0: Evolution of Optical Flow Estimation with Deep Networks [J].
Ilg, Eddy ;
Mayer, Nikolaus ;
Saikia, Tonmoy ;
Keuper, Margret ;
Dosovitskiy, Alexey ;
Brox, Thomas .
30TH IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR 2017), 2017, :1647-1655
[7]  
Jensen J. A., 1996, Medical & Biological Engineering & Computing, V34, P351
[8]   Transcutaneous measurement and spectrum analysis of heart wall vibrations [J].
Kanai, H ;
Sato, M ;
Koiwa, Y ;
Chubachi, N .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1996, 43 (05) :791-810
[9]  
Lucas B. D., 1981, IJCAI
[10]   Artifact reduction in low bit rate DCT-based image compression [J].
Luo, JB ;
Chen, CW ;
Parker, KJ ;
Huang, TS .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 1996, 5 (09) :1363-1368