Continuous Cardiac Output Monitoring: What Do Validation Studies Tell Us?

被引:1
作者
Critchley L.A.H. [1 ]
Huang L. [2 ]
Zhang J. [1 ]
机构
[1] Department of Anaesthesia and Intensive Care, Prince of Wales Hospital, The Chinese University of Hong Kong, Shatin, New Territories
[2] Department of Anaesthesia and Surgical Intensive Care, Peking University First Hospital, Beijing
关键词
Bland–Altman; Cardiac output; Monitoring; Pulse contour; Thermodilution; Trending;
D O I
10.1007/s40140-014-0062-9
中图分类号
学科分类号
摘要
Several continuous cardiac output (CO) monitoring systems have been developed. None are ideal for use in anaesthesia or critical care. They all lack precision as shown by Bland–Altman studies. However, some provide reliable CO trending, which is useful for guiding fluid optimization protocols. The key issue is which systems are reliable, and this has not been helped by a lack of understanding of validation statistics in the literature. Recent studies suggest that none of the current intra-arterial pulse contour systems trend CO reliably. Stroke volume variability may provide a reliable alternative. Strangely, Nexfin finger plethysmography did reliably trend CO during routine surgery, but not during critical care. BioReactance also appears to trend CO acceptably, but its performance is affected by certain types of surgery that alter the pathways of electrical flux. Oesophageal Doppler is now well established for guiding goal-directed fluid regimens, and its trending of CO changes seems reliable. © 2014, Springer Science + Business Media New York.
引用
收藏
页码:242 / 250
页数:8
相关论文
共 50 条
  • [31] Intraoperative validation of a new system for invasive continuous cardiac output measurement
    D'Ancona, Giuseppe
    Parrinello, Matteo
    Santise, Gianluca
    Biondo, Domenico
    Pirone, Francesco
    Sciacca, Sergio
    Turrisi, Marco
    Arcadipane, Antonio
    Pilato, Michele
    INTENSIVE CARE MEDICINE, 2009, 35 (05) : 943 - 947
  • [32] CONTINUOUS MEASUREMENT OF CARDIAC-OUTPUT BY THE FICK PRINCIPLE - CLINICAL VALIDATION IN INTENSIVE-CARE
    KEINANEN, O
    TAKALA, J
    KARI, A
    CRITICAL CARE MEDICINE, 1992, 20 (03) : 360 - 365
  • [33] Continuous cardiac output monitoring with pulse contour analysis: A comparison with lithium indicator dilution cardiac output measurement
    Pittman, J
    Bar-Yosef, S
    SumPing, J
    Sherwood, M
    Mark, J
    CRITICAL CARE MEDICINE, 2005, 33 (09) : 2015 - 2021
  • [34] Non-invasive cardiac output monitoring in children: clinical validation
    Y Vandormael
    T Vu
    M Gewillig
    D Vlasselaers
    Critical Care, 14 (Suppl 1):
  • [35] Tracking changes in cardiac output: methodological considerations for the validation of monitoring devices
    Squara, Pierre
    Cecconi, Maurizio
    Rhodes, Andrew
    Singer, Mervyn
    Chiche, Jean-Daniel
    INTENSIVE CARE MEDICINE, 2009, 35 (10) : 1801 - 1808
  • [36] Tracking changes in cardiac output: methodological considerations for the validation of monitoring devices
    Pierre Squara
    Maurizio Cecconi
    Andrew Rhodes
    Mervyn Singer
    Jean-Daniel Chiche
    Intensive Care Medicine, 2009, 35 : 1801 - 1808
  • [37] A prospective study of the accuracy and precision of continuous cardiac output monitoring devices as compared to intermittent thermodilution
    Cecconi, M.
    Dawson, D.
    Casaretti, R.
    Grounds, R. M.
    Rhodes, A.
    MINERVA ANESTESIOLOGICA, 2010, 76 (12) : 1010 - 1017
  • [38] Continuous cardiac output monitoring by peripheral blood pressure waveform analysis
    Mukkamala, R
    Reisner, AT
    Hojman, HM
    Mark, RG
    Cohen, RJ
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2006, 53 (03) : 459 - 467
  • [39] Continuous monitoring of cardiac output - Advanced technology for advanced patient care?
    Van Aken, H
    Booke, M
    CRITICAL CARE MEDICINE, 1999, 27 (02) : 233 - 234
  • [40] Sustained attention in the elderly: What do we know and what does it tell us about cognitive aging?
    Staub, Berengere
    Doignon-Camus, Nadege
    Despres, Olivier
    Bonnefond, Anne
    AGEING RESEARCH REVIEWS, 2013, 12 (02) : 459 - 468