Continuous Cardiac Output Monitoring: What Do Validation Studies Tell Us?

被引:1
作者
Critchley L.A.H. [1 ]
Huang L. [2 ]
Zhang J. [1 ]
机构
[1] Department of Anaesthesia and Intensive Care, Prince of Wales Hospital, The Chinese University of Hong Kong, Shatin, New Territories
[2] Department of Anaesthesia and Surgical Intensive Care, Peking University First Hospital, Beijing
关键词
Bland–Altman; Cardiac output; Monitoring; Pulse contour; Thermodilution; Trending;
D O I
10.1007/s40140-014-0062-9
中图分类号
学科分类号
摘要
Several continuous cardiac output (CO) monitoring systems have been developed. None are ideal for use in anaesthesia or critical care. They all lack precision as shown by Bland–Altman studies. However, some provide reliable CO trending, which is useful for guiding fluid optimization protocols. The key issue is which systems are reliable, and this has not been helped by a lack of understanding of validation statistics in the literature. Recent studies suggest that none of the current intra-arterial pulse contour systems trend CO reliably. Stroke volume variability may provide a reliable alternative. Strangely, Nexfin finger plethysmography did reliably trend CO during routine surgery, but not during critical care. BioReactance also appears to trend CO acceptably, but its performance is affected by certain types of surgery that alter the pathways of electrical flux. Oesophageal Doppler is now well established for guiding goal-directed fluid regimens, and its trending of CO changes seems reliable. © 2014, Springer Science + Business Media New York.
引用
收藏
页码:242 / 250
页数:8
相关论文
共 50 条
  • [21] New generation continuous cardiac output monitoring from carbon dioxide elimination
    Philip J. Peyton
    Mats Wallin
    Magnus Hallbäck
    BMC Anesthesiology, 19
  • [22] Cardiac Output Monitoring: Is There a Gold Standard and How Do the Newer Technologies Compare?
    Pugsley, Jacob
    Lerner, Adam B.
    SEMINARS IN CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2010, 14 (04) : 274 - 282
  • [23] Validation of continuous cardiac output technologies: consensus still awaited
    Maurizio Cecconi
    Andrew Rhodes
    Critical Care, 13
  • [24] Continuous thermodilution cardiac output: clinical validation against a reference technique of known accuracy
    Schmid, ER
    Schmidlin, D
    Tornic, M
    Seifert, B
    INTENSIVE CARE MEDICINE, 1999, 25 (02) : 166 - 172
  • [25] Correlation of cardiac output measured by non-invasive continuous cardiac output monitoring (NICOM) and thermodilution in patients undergoing off-pump coronary artery bypass surgery
    Cheung, Hoiyin
    Dong, Quan
    Dong, Rong
    Yu, Buwei
    JOURNAL OF ANESTHESIA, 2015, 29 (03) : 416 - 420
  • [26] Continuous monitoring of cardiac output: How many assumptions are valid?
    Bengur, AR
    Meliones, JN
    CRITICAL CARE MEDICINE, 2000, 28 (06) : 2168 - 2169
  • [27] Continuous monitoring of cardiac output during pneumoperitoneum by esophagal Doppler
    F Zveibil
    S Yvri
    A Schlepak
    NM Akhoul
    Critical Care, 7 (Suppl 2):
  • [28] Continuous cardiac output monitoring – further applications of the thermodilution principle
    B. W. Böttiger
    Intensive Care Medicine, 1999, 25 : 131 - 133
  • [29] Arterial pressure-based cardiac output monitoring: a multicenter validation of the third-generation software in septic patients
    De Backer, Daniel
    Marx, Gernot
    Tan, Andrew
    Junker, Christopher
    Van Nuffelen, Marc
    Huter, Lars
    Ching, Willy
    Michard, Frederic
    Vincent, Jean-Louis
    INTENSIVE CARE MEDICINE, 2011, 37 (02) : 233 - 240
  • [30] Validation of a continuous cardiac output measurement using arterial pressure waveforms