Voltammetric determination of folic acid at physiological pH values by using a glassy carbon electrode modified with a multilayer composite consisting of polyoxometalate (H8P2Mo16V2O62) and reduced graphene oxide and prepared via layer-by-layer self-assembly and in-situ photoreduction

被引:0
作者
Hengbin Xu
Zhenyuan Bai
Guangning Wang
Kevin P. O’Halloran
Lichao Tan
Haijun Pang
Huiyuan Ma
机构
[1] Harbin University of Science and Technology,Key Laboratory of Green Chemical Engineering and Technology of College of Heilongjiang Province, College of Chemical and Environmental Engineering
[2] Georgia Gwinnett College,undefined
[3] School of Science and Technology,undefined
来源
Microchimica Acta | 2017年 / 184卷
关键词
Electrochemistry; Cyclic voltammetry; Differential pulse voltammetry; Electrochemical impedance spectroscopy; Dopamine; Uric acid; Hexacyanoferrrate; Sensor; Carbon-based material; Human serum samples;
D O I
暂无
中图分类号
学科分类号
摘要
Vanadium-substituted polyoxometalate clusters of type H8P2Mo16V2O62 and reduced graphene oxide (rGO) were incorporated into a multilayer composite film via combining layer-by-layer self-assembly (using polyethyleneimine) and in-situ UV photoreduction. The growth of the multilayer film was monitored by UV-vis spectroscopy. The UV-induced conversion of graphene oxide to rGO in the multilayer film is due to the photocatalytic activity of P2Mo16V2 and was proven by X-ray photoelectron spectroscopy. The material was placed on a glassy carbon electrode (GCE) where it displayed good electrocatalytic activity towards oxidation of folic acid (FA) as demonstrated by cyclic voltammetry and differential pulse voltammetry. The modified GCE (best operated at a working voltage of 0.75 V vs Ag/AgCl and a scan rate of 50 mV s−1) compared to films containing either P2Mo16V2 or rGO only. The effects of the number of bilayers and of pH values on the electro-oxidation were investigated. The modified GCE was applied to selective determination of FA even in the presence of dopamine (DA) and uric acid (UA) at physiological pH. In fact, the modified GCE may also be applied to the simultaneous determination of DA, UA and FA. The amperometric response to FA increases linearly in the 10 nM to 0.8 mM FA concentration range, with a 0.28 nM detection limit. The sensor was successfully applied to the determination of FA in spiked human serum samples.
引用
收藏
页码:4295 / 4303
页数:8
相关论文
共 157 条
[51]  
Ammam M(undefined)undefined undefined undefined undefined-undefined
[52]  
Wang JJ(undefined)undefined undefined undefined undefined-undefined
[53]  
Han DX(undefined)undefined undefined undefined undefined-undefined
[54]  
Wang XH(undefined)undefined undefined undefined undefined-undefined
[55]  
Qi B(undefined)undefined undefined undefined undefined-undefined
[56]  
Zhao MS(undefined)undefined undefined undefined undefined-undefined
[57]  
Fernandes DM(undefined)undefined undefined undefined undefined-undefined
[58]  
Barbosa ADS(undefined)undefined undefined undefined undefined-undefined
[59]  
Pires J(undefined)undefined undefined undefined undefined-undefined
[60]  
Balula SS(undefined)undefined undefined undefined undefined-undefined