Ultrasound-guided insertion of intra-aortic balloon counterpulsation in intensive care: description of the technique

被引:0
作者
David Rene Rodriguez Lima
Ever Julián Duran
Ever Leonardo Rojas Díaz
Darío Isaías Pinilla Rojas
Mario Andrés Mercado Díaz
Yury Forlán Bustos Martínez
机构
[1] Hospital Universitario Mayor Méderi–Universidad Del Rosario,Emergency Medicine and Critical and Intensive Care Medicine
[2] Hospital Universitario Mayor Méderi –Universidad del Rosario,Resident, Critical and Intensive Care Medicine
[3] Hospital Universitario Mayor Méderi–Universidad del Rosario,Anesthesiology and Critical and Intensive Care Medicine
[4] Hospital Universitario Mayor Méderi–Universidad del Rosario,Critical and Intensive Care Medicine
[5] Universidad del Rosario,Emergency Medicine Department of Ultrasound and Simulation
来源
The Ultrasound Journal | / 12卷
关键词
Ultrasound; Intra-aortic balloon counterpulsation (IAoBC); Mechanical circulatory support; Ultrasound education;
D O I
暂无
中图分类号
学科分类号
摘要
Intra-aortic balloon counterpulsation (IAoBC) is a mechanical circulatory support device that has been used for more than 50 years, mainly for cardiogenic shock. Although its effect on mortality is controversial, IAoBC is still used in a wide variety of pre- and postoperative clinical settings in cardiac surgery centers. IAoBC has a complication rate of approximately 30%, mostly associated with problems during insertion and malpositioning. Thus, an insertion technique based on the use of ultrasound at the patient’s bedside in the intensive care unit (ICU) is proposed.
引用
收藏
相关论文
共 84 条
[1]  
Parissis H(2016)IABP: history-evolution-pathophysiology-indications: what we need to know J Cardiothorac Surg 11 122-318
[2]  
Graham V(1991)The intra-aortic balloon pump system: current roles and future directions J Appl Cardiol 6 313-674
[3]  
Lampridis S(1990)Origins of intraaortic balloon pumping Ann Thoracic Surg 50 672-675
[4]  
Lau M(1962)Diastolic balloon pumping (with carbon dioxide) in the aorta—a mechanical assistance to the failing circulation Am Heart J 63 669-99
[5]  
Hooks G(2010)Visceral arterial compromise during intra-aortic balloon counterpulsation therapy Circulation. 122 92-268
[6]  
Mhandu PC(1980)Complications of the intraaortic balloon counterpulsation device: clinical and morphologic observations in 45 necropsy patients Am J Cardiol 45 260-346
[7]  
Freedman RJ(2006)In which patients should sheathless IABP be used? An analysis of vascular complications in 1211 cases J Card Surg 21 342-79
[8]  
Kantrowitz A(2016)Efficacy and safety of preoperative intra-aortic balloon pump use in patients undergoing cardiac surgery: a systematic review and meta-analysis Int J Cardiol 207 67-104
[9]  
Moulopoulos SD(2010)The need for intra aortic balloon pump support following open heart surgery: risk analysis and outcome J Cardiothorac Surg 5 20-302
[10]  
Topaz S(2018)Vascular complications following intra-aortic balloon pump implantation: an updated review Perfusion. 33 96-150