Determination of trace transition metals in environmental matrices by chelation ion chromatography

被引:0
作者
Sandro M. Murgia
Roberta Selvaggi
Antonio Poletti
机构
[1] Università degli Studi,Dipartimento di Chimica
[2] di Perugia,undefined
来源
Environmental Monitoring and Assessment | 2011年 / 174卷
关键词
Ionic chromatography; Heavy metal; PDCA; Validation; Natural sample monitoring; Automatic monitoring system;
D O I
暂无
中图分类号
学科分类号
摘要
Trace transition metals (Fe3 + , Mn, Cu, Cd, Co, Zn, Ni) in environmental samples were analyzed by chelation ion chromatography using a mixed bed ion-exchange column with pyridine-2,6-dicarboxylic acid (PDCA) and oxalic acid as eluent and large volume direct injection (1,000 μl). The two eluents, PDCA and oxalic acid, were tested, and repeatability and detection limits were compared. The total analysis time was ~15 min. The separation with PDCA was more successful than that obtained with acid oxalic. It was observed that utilizing PDCA resulted in lower detection limits, higher repeatability, and a quantitative detection of Cd and Mn, which coelute as a single peak when using the oxalic acid. At last, the PDCA calibration graphs resulted linear (r2 > 0.999) in the range 0.4–1,000 μg/L. The procedure was applied to the analysis of metals in soils and in water samples. The results obtained from the analysis of natural waters have demonstrated that the method is simple and efficient, therefore, can be used for the determination of metals in natural waters using a continuous and automatic monitoring system.
引用
收藏
页码:313 / 326
页数:13
相关论文
共 80 条
[1]  
Bashir W(1994)Is my calibration linear? Analyst 119 2363-7
[2]  
Paull B(1985)Analytical methods for sludge Issue 64 3-undefined
[3]  
Bruno P(2002)Ionic strength, pH and temperature effects upon selectivity for transition and heavy metal ions when using chelation ion chromatography with an iminodiacetic acid bonded silica gel column and simple inorganic eluents Journal of Chromatography A 942 73-undefined
[4]  
Caselli M(2006)Ion chromatographic determination of heavy metals in airborne particulate with preconcentration and large volume direct injection Chromatographia 64 537-undefined
[5]  
Gennaro G(1999)New strategies for determination of transition metals by complexation ion exchange chromatography and post column reaction Journal of Chromatography A 847 251-undefined
[6]  
Ielpo P(1998)Determination of transition metals in mineral waters by ion chromatography and spectrophotometric detection Annali di Chimica 88 819-undefined
[7]  
Ladisa T(1997)Use of ion chromatography for the determination of transition metals in the control of sewage-treatment-plant and related waters Journal of Chromatography, A 770 185-undefined
[8]  
Placentino CM(2000)Improved scheme of chelation ion chromatography with a mixed eluent for the simultaneous analysis of transition metals at μg/l Journal of Chromatography A 883 127-undefined
[9]  
Cardellicchio N(2000) levels Analytica Chimica Acta 407 319-undefined
[10]  
Cavalli S(1998)Ion chromatography of heavy and transition metals by on and post-column derivatisations Journal of Chromatography A 829 167-undefined