Symmetric Biomechanically Guided Prone-to-Supine Breast Image Registration

被引:0
|
作者
Björn Eiben
Vasileios Vavourakis
John H. Hipwell
Sven Kabus
Thomas Buelow
Cristian Lorenz
Thomy Mertzanidou
Sara Reis
Norman R. Williams
Mohammed Keshtgar
David J. Hawkes
机构
[1] University College London,Department of Medical Physics & Biomedical Engineering, Centre for Medical Image Computing
[2] Philips GmbH Innovative Technologies,Clinical Trials Group, Division of Surgery
[3] Research Laboratories Hamburg,Department of Surgery
[4] University College London,Division of Surgery
[5] Royal Free Hospital,undefined
[6] University College London,undefined
来源
Annals of Biomedical Engineering | 2016年 / 44卷
关键词
Image analysis; Image registration; Breast cancer; Biomechanics; Modelling; Finite difference method;
D O I
暂无
中图分类号
学科分类号
摘要
Prone-to-supine breast image registration has potential application in the fields of surgical and radiotherapy planning, image guided interventions, and multi-modal cancer diagnosis, staging, and therapy response prediction. However, breast image registration of three dimensional images acquired in different patient positions is a challenging problem, due to large deformations induced to the soft breast tissue caused by the change in gravity loading. We present a symmetric, biomechanical simulation based registration framework which aligns the images in a central, virtually unloaded configuration. The breast tissue is modelled as a neo-Hookean material and gravity is considered as the main source of deformation in the original images. In addition to gravity, our framework successively applies image derived forces directly into the unloading simulation in place of a subsequent image registration step. This results in a biomechanically constrained deformation. Using a finite difference scheme avoids an explicit meshing step and enables simulations to be performed directly in the image space. The explicit time integration scheme allows the motion at the interface between chest and breast to be constrained along the chest wall. The feasibility and accuracy of the approach presented here was assessed by measuring the target registration error (TRE) using a numerical phantom with known ground truth deformations, nine clinical prone MRI and supine CT image pairs, one clinical prone-supine CT image pair and four prone-supine MRI image pairs. The registration reduced the mean TRE for the numerical phantom experiment from initially 19.3 to 0.9 mm and the combined mean TRE for all fourteen clinical data sets from 69.7 to 5.6 mm.
引用
收藏
页码:154 / 173
页数:19
相关论文
共 50 条
  • [1] Symmetric Biomechanically Guided Prone-to-Supine Breast Image Registration
    Eiben, Bjoern
    Vavourakis, Vasileios
    Hipwell, John H.
    Kabus, Sven
    Buelow, Thomas
    Lorenz, Cristian
    Mertzanidou, Thomy
    Reis, Sara
    Williams, Norman R.
    Keshtgar, Mohammed
    Hawkes, David J.
    ANNALS OF BIOMEDICAL ENGINEERING, 2016, 44 (01) : 154 - 173
  • [2] BIOMECHANICALLY GUIDED PRONE-TO-SUPINE IMAGE REGISTRATION OF BREAST MRI USING AN ESTIMATED REFERENCE STATE
    Eiben, B.
    Han, L.
    Hipwell, J.
    Mertzanidou, T.
    Kabus, S.
    Buelow, T.
    Lorenz, C.
    Newstead, G. M.
    Abe, H.
    Keshtgar, M.
    Ourselin, S.
    Hawkes, D. J.
    2013 IEEE 10TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2013, : 214 - 217
  • [3] A review of biomechanically informed breast image registration
    Hipwell, John H.
    Vavourakis, Vasileios
    Han, Lianghao
    Mertzanidou, Thomy
    Eiben, Bjoern
    Hawkes, David J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (02) : R1 - R31
  • [4] Image to physical space registration of supine breast MRI for image guided breast surgery
    Conley, Rebekah H.
    Meszoely, Ingrid M.
    Pheiffer, Thomas S.
    Weis, Jared A.
    Yankeelov, Thomas E.
    Miga, Michael I.
    MEDICAL IMAGING 2014: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2014, 9036
  • [5] A HYBRID FEM-BASED METHOD FOR ALIGNING PRONE AND SUPINE IMAGES FOR IMAGE GUIDED BREAST SURGERY
    Han, Lianghao
    Hipwell, John
    Mertzanidou, Thomy
    Carter, Tim
    Modat, Marc
    Ourselin, Sebastien
    Hawkes, David
    2011 8TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2011, : 1239 - 1242
  • [6] A Nonlinear Biomechanical Model Based Registration Method for Aligning Prone and Supine MR Breast Images
    Han, Lianghao
    Hipwell, John H.
    Eiben, Bjoern
    Barratt, Dean
    Modat, Marc
    Ourselin, Sebastien
    Hawkes, David J.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2014, 33 (03) : 682 - 694
  • [7] Breast Tumor Localization by Prone to Supine Landmark Driven Registration for Surgical Planning
    Alfano, Felicia
    Cordero-Grande, Lucilio
    Ortuno, Juan E.
    Ferreres Garcia, Karla
    Garcia-Sevilla, Monica
    Bueno Zamora, Oscar
    Herrero Conde, Mercedes
    Lizarraga, Santiago
    Santos, Andres
    Pascau, Javier
    Ledesma-Carbayo, Maria J.
    IEEE ACCESS, 2022, 10 : 122901 - 122911
  • [8] Supine magnetic resonance image registration for breast surgery: insights on material mechanics
    Ringel, Morgan J.
    Richey, Winona L.
    Heiselman, Jon S.
    Luo, Ma
    Meszoely, Ingrid M.
    Miga, Michael I.
    JOURNAL OF MEDICAL IMAGING, 2022, 9 (06)
  • [9] CT colonography: inverse-consistent symmetric registration of prone and supine inner colon surfaces
    Roth, Holger R.
    McClelland, Jamie R.
    Modat, Marc
    Hampshire, Thomas E.
    Boone, Darren J.
    Helbren, Emma
    Plumb, Andrew
    Hu, Mingxing
    Ourselin, Sebastien
    Halligan, Steve
    Hawkes, David J.
    MEDICAL IMAGING 2013: IMAGE PROCESSING, 2013, 8669
  • [10] Preliminary Feasibility Study of Imaging Registration Between Supine and Prone Breast CT in Breast Cancer Radiotherapy Using Residual Recursive Cascaded Networks
    Ouyang, Xiaoyun
    Liang, Xiaokun
    Xie, Yaoqin
    IEEE ACCESS, 2021, 9 (09): : 3315 - 3325