Respiratory variation in peak aortic velocity accurately predicts fluid responsiveness in children undergoing neurosurgery under general anesthesia

被引:0
作者
Kavita G. Morparia
Srijaya K. Reddy
Laura J. Olivieri
Michael C. Spaeder
Jennifer J. Schuette
机构
[1] Children’s Hospital of New Jersey,Division of Pediatric Critical Care Medicine, Department of Pediatrics
[2] Newark Beth Israel Medical Center,Division of Anesthesiology, Children’s National Medical Center
[3] George Washington University,Division of Cardiology, Children’s National Medical Center
[4] George Washington University,Division of Pediatric Critical Care Medicine, UVA Children’s Hospital
[5] University of Virginia,Division of Pediatric Anesthesiology and Critical Care Medicine
[6] Johns Hopkins School of Medicine,undefined
来源
Journal of Clinical Monitoring and Computing | 2018年 / 32卷
关键词
Fluid responsiveness; Cardiopulmonary interaction; Bedside ultrasound; Echocardiography; Respiratory variation in aortic velocity;
D O I
暂无
中图分类号
学科分类号
摘要
The determination of fluid responsiveness in the critically ill child is of vital importance, more so as fluid overload becomes increasingly associated with worse outcomes. Dynamic markers of volume responsiveness have shown some promise in the pediatric population, but more research is needed before they can be adopted for widespread use. Our aim was to investigate effectiveness of respiratory variation in peak aortic velocity and pulse pressure variation to predict fluid responsiveness, and determine their optimal cutoff values. We performed a prospective, observational study at a single tertiary care pediatric center. Twenty-one children with normal cardiorespiratory status undergoing general anesthesia for neurosurgery were enrolled. Respiratory variation in peak aortic velocity (ΔVpeak ao) was measured both before and after volume expansion using a bedside ultrasound device. Pulse pressure variation (PPV) value was obtained from the bedside monitor. All patients received a 10 ml/kg fluid bolus as volume expansion, and were qualified as responders if stroke volume increased >15% as a result. Utility of ΔVpeak ao and PPV and to predict responsiveness to volume expansion was investigated. A baseline ΔVpeak ao value of greater than or equal to 12.3% best predicted a positive response to volume expansion, with a sensitivity of 77%, specificity of 89% and area under receiver operating characteristic curve of 0.90. PPV failed to demonstrate utility in this patient population. Respiratory variation in peak aortic velocity is a promising marker for optimization of perioperative fluid therapy in the pediatric population and can be accurately measured using bedside ultrasonography. More research is needed to evaluate the lack of effectiveness of pulse pressure variation for this purpose.
引用
收藏
页码:221 / 226
页数:5
相关论文
共 23 条
  • [21] Respiratory variations in aortic blood flow velocity and inferior vena cava diameter as predictors of fluid responsiveness in mechanically ventilated children using transthoracic echocardiography in a pediatric PICU
    K El Halimi
    M Negadi
    H Bouguetof
    L Zemour
    D Boumendil
    Z Chentouf Mentouri
    Critical Care, 19 (Suppl 1):
  • [22] Carotid Artery Corrected Flow Time and Respiratory Variations of Peak Blood Flow Velocity for Prediction of Hypotension After Induction of General Anesthesia in Adult Patients Undergoing Elective Surgery: A Prospective Observational Study
    Maitra, Souvik
    Baidya, Dalim K.
    Anand, Rahul K.
    Subramanium, Rajeshwari
    Bhattacharjee, Sulagna
    JOURNAL OF ULTRASOUND IN MEDICINE, 2020, 39 (04) : 721 - 730
  • [23] Dynamic Arterial Elastance as a Predictor of Intraoperative Fluid Responsiveness in Elderly Patient over 70 Years of Age Undergoing Spine Surgery in the Prone Position Under General Anesthesia: A Validation Study
    Oh, Eun Jung
    Cho, Eun Ah
    Jun, Joohyun
    Lee, Sung Hyun
    Lee, Seunghyeon
    Ahn, Jin Hee
    JOURNAL OF CLINICAL MEDICINE, 2025, 14 (04)