Cardiac computed tomography compared with two-dimensional transesophageal echocardiography for the detection and assessment of atrial septal pouches

被引:0
|
作者
Mateusz K. Hołda
Agata Krawczyk-Ożóg
Mateusz Koziej
Wiesław Pawlik
Danuta Sorysz
Karolina Wszołek
Dariusz Dudek
Wiesława Klimek-Piotrowska
机构
[1] Jagiellonian University Medical College,HEART
[2] Jagiellonian University Medical College, Heart Embryology and Anatomy Research Team, Department of Anatomy
[3] Jagiellonian University Medical College,Department of Interventional Cardiology, University Hospital
来源
The International Journal of Cardiovascular Imaging | 2018年 / 34卷
关键词
Septal pouch; Left atrium; Interatrial septum; Patent foramen ovale; Cryptogenic stroke; MSCT;
D O I
暂无
中图分类号
学科分类号
摘要
The aim of this study is to compare the two-dimensional transesophageal echocardiography (2D-TEE) with multi-slice computed tomography (MSCT) and with autopsied material to evaluate the ability and precision of the imaging methods for the detection and assessment of septal pouch (SP). One hundred and fifty patients that underwent both 2D-TEE and MSCT and 50 autopsied human hearts were investigated. In MSCT, the interatrial septum was classified as a left SP in 37.3%, right SP in 3.3%, and patent foramen ovale (PFO) channel in 3.3%. In 2D-TEE, the interatrial septum was classified as a left SP in 39.3%, right SP in 11.3%, double SP in 4.7%, and PFO channel in 2.0%. The weighted kappa coefficient between MSCT and 2D-TEE in assessing the septum morphology was 0.59. The prevalence of the left SP is lower when it is evaluated by MSCT or 2D-TEE than by anatomical study, but this difference is insignificant (37.3% vs. 44.0%, p = 0.40, and 39.3% vs. 44.0%, p = 0.56, respectively). The prevalence of left SPs is lower when detected by MSCT or 2D-TEE than during autopsy, but the difference is statistically insignificant (37.3% vs. 44.0%, p = 0.40, and 39.3% vs. 44.0%, p = 0.56, respectively). Both 2D-TEE and MSCT are comparable techniques for detecting left-sided SPs with the insignificant lower prevalence of detecting left-sided SPs compared to autopsied material. However, TEE with the contrast seems to be superior over MSCT due to the possibility of unambiguous PFO channel detection. Therefore, TEE with contrast should be preferred over MSCT in the identification of left-sided SPs.
引用
收藏
页码:1305 / 1313
页数:8
相关论文
共 50 条
  • [41] Detection and diagnosis of iatrogenic inadvertent diversion of partial inferior vena cava into the left atrium by transesophageal echocardiography during large posteroinferior surgical atrial septal defect closure
    Yanzi Zhang
    Haibo Song
    Xin Qiao
    Xijun Xiao
    Jin Liu
    Xiao Wang
    Journal of Anesthesia, 2015, 29 : 442 - 445
  • [42] Assessment of left atrial dysfunction in obstructive sleep apnea patients with the two dimensional speckle-tracking echocardiography
    Refik Emre Altekin
    Atakan Yanikoglu
    Mustafa Serkan Karakas
    Deniz Ozel
    Murathan Kucuk
    Huseyin Yilmaz
    Ibrahim Demir
    Clinical Research in Cardiology, 2012, 101 : 403 - 413
  • [43] Assessment of left atrial function in feline hypertrophic cardiomyopathy by using two- dimensional speckle tracking echocardiography
    Kiatsilapanan, Arisara
    Surachetpong, Sirilak Disatian
    BMC VETERINARY RESEARCH, 2020, 16 (01)
  • [44] Assessment of left atrial function in feline hypertrophic cardiomyopathy by using two- dimensional speckle tracking echocardiography
    Arisara Kiatsilapanan
    Sirilak Disatian Surachetpong
    BMC Veterinary Research, 16
  • [45] Assessment of left atrial dysfunction in obstructive sleep apnea patients with the two dimensional speckle-tracking echocardiography
    Altekin, Refik Emre
    Yanikoglu, Atakan
    Karakas, Mustafa Serkan
    Ozel, Deniz
    Kucuk, Murathan
    Yilmaz, Huseyin
    Demir, Ibrahim
    CLINICAL RESEARCH IN CARDIOLOGY, 2012, 101 (06) : 403 - 413
  • [46] Evaluation of left atrial function via two-dimensional speckle-tracking echocardiography in patients with coronary artery ectasia
    Aghajani, Hasan
    Faal, Mohsen
    Hosseinsabet, Ali
    Mohseni-Badalabadi, Reza
    JOURNAL OF CLINICAL ULTRASOUND, 2017, 45 (04) : 231 - 237
  • [47] Conscious sedation for transcatheter implantation of atrial septal occluders with two- and three-dimensional transoesophageal echocardiography guidance - a feasibility and safety study
    Lipiec, Piotr
    Miskowiec, Dawid
    Peruga, Jan Z.
    Plewka, Michal
    Szymczyk, Ewa
    Wejner-Mik, Paulina
    Kupczynska, Karolina
    Kasprzak, Jaroslaw D.
    KARDIOLOGIA POLSKA, 2018, 76 (02) : 406 - 412
  • [48] Comparison of Three-Dimensional Speckle Tracking Echocardiography and Two-Dimensional Echocardiography for Evaluation of Left Atrial Size and Function in Healthy Volunteers (Results from the MAGYAR-Healthy Study)
    Nemes, Attila
    Domsik, Peter
    Kalapos, Anita
    Lengyel, Csaba
    Orosz, Andrea
    Forster, Tamas
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2014, 31 (07): : 865 - 871
  • [49] Assessment of visit-to-visit variability in systolic blood pressure over 5 years and phasic left atrial function by two-dimensional speckle-tracking echocardiography
    Tanaka, Shinichiro
    Segawa, Tomonori
    Noda, Toshiyuki
    Tsugita, Natsumi
    Fuseya, Takahiro
    Kawaguchi, Tomonori
    Iwama, Makoto
    Watanabe, Sachiro
    Minagawa, Taro
    Minatoguchi, Shinya
    Hiroyuki, Okura
    HEART AND VESSELS, 2021, 36 (06) : 827 - 835
  • [50] Assessment of visit-to-visit variability in systolic blood pressure over 5 years and phasic left atrial function by two-dimensional speckle-tracking echocardiography
    Shinichiro Tanaka
    Tomonori Segawa
    Toshiyuki Noda
    Natsumi Tsugita
    Takahiro Fuseya
    Tomonori Kawaguchi
    Makoto Iwama
    Sachiro Watanabe
    Taro Minagawa
    Shinya Minatoguchi
    Okura Hiroyuki
    Heart and Vessels, 2021, 36 : 827 - 835