Cardiac computed tomography compared with two-dimensional transesophageal echocardiography for the detection and assessment of atrial septal pouches

被引:0
|
作者
Mateusz K. Hołda
Agata Krawczyk-Ożóg
Mateusz Koziej
Wiesław Pawlik
Danuta Sorysz
Karolina Wszołek
Dariusz Dudek
Wiesława Klimek-Piotrowska
机构
[1] Jagiellonian University Medical College,HEART
[2] Jagiellonian University Medical College, Heart Embryology and Anatomy Research Team, Department of Anatomy
[3] Jagiellonian University Medical College,Department of Interventional Cardiology, University Hospital
来源
The International Journal of Cardiovascular Imaging | 2018年 / 34卷
关键词
Septal pouch; Left atrium; Interatrial septum; Patent foramen ovale; Cryptogenic stroke; MSCT;
D O I
暂无
中图分类号
学科分类号
摘要
The aim of this study is to compare the two-dimensional transesophageal echocardiography (2D-TEE) with multi-slice computed tomography (MSCT) and with autopsied material to evaluate the ability and precision of the imaging methods for the detection and assessment of septal pouch (SP). One hundred and fifty patients that underwent both 2D-TEE and MSCT and 50 autopsied human hearts were investigated. In MSCT, the interatrial septum was classified as a left SP in 37.3%, right SP in 3.3%, and patent foramen ovale (PFO) channel in 3.3%. In 2D-TEE, the interatrial septum was classified as a left SP in 39.3%, right SP in 11.3%, double SP in 4.7%, and PFO channel in 2.0%. The weighted kappa coefficient between MSCT and 2D-TEE in assessing the septum morphology was 0.59. The prevalence of the left SP is lower when it is evaluated by MSCT or 2D-TEE than by anatomical study, but this difference is insignificant (37.3% vs. 44.0%, p = 0.40, and 39.3% vs. 44.0%, p = 0.56, respectively). The prevalence of left SPs is lower when detected by MSCT or 2D-TEE than during autopsy, but the difference is statistically insignificant (37.3% vs. 44.0%, p = 0.40, and 39.3% vs. 44.0%, p = 0.56, respectively). Both 2D-TEE and MSCT are comparable techniques for detecting left-sided SPs with the insignificant lower prevalence of detecting left-sided SPs compared to autopsied material. However, TEE with the contrast seems to be superior over MSCT due to the possibility of unambiguous PFO channel detection. Therefore, TEE with contrast should be preferred over MSCT in the identification of left-sided SPs.
引用
收藏
页码:1305 / 1313
页数:8
相关论文
共 50 条
  • [31] Partially unroofed coronary sinus diagnosed by real-time three-dimensional transesophageal echocardiography after operation of secundum atrial septal defect
    Chen, Hai-yan
    Pan, Cui-zhen
    Shu, Xian-hong
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2015, 31 (01) : 45 - 46
  • [32] Partially unroofed coronary sinus diagnosed by real-time three-dimensional transesophageal echocardiography after operation of secundum atrial septal defect
    Hai-yan Chen
    Cui-zhen Pan
    Xian-hong Shu
    The International Journal of Cardiovascular Imaging, 2015, 31 : 45 - 46
  • [33] Evaluation of the left atrial function by two-dimensional speckle-tracking echocardiography in diabetic patients with obesity
    Reza Mohseni-Badalabadi
    Samira Mehrabi-Pari
    Ali Hosseinsabet
    The International Journal of Cardiovascular Imaging, 2020, 36 : 643 - 652
  • [34] Impact of Diastolic Dysfunction Grade on Left Atrial Mechanics Assessed by Two-Dimensional Speckle Tracking Echocardiography
    Otani, Kyoko
    Takeuchi, Masaaki
    Kaku, Kyoko
    Haruki, Nobuhiko
    Yoshitani, Hidetoshi
    Tamura, Masahito
    Abe, Haruhiko
    Okazaki, Masahiro
    Ota, Toshiyuki
    Lang, Roberto M.
    Otsuji, Yutaka
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2010, 23 (09) : 961 - 967
  • [35] Evaluation of the left atrial function by two-dimensional speckle-tracking echocardiography in diabetic patients with obesity
    Mohseni-Badalabadi, Reza
    Mehrabi-Pari, Samira
    Hosseinsabet, Ali
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2020, 36 (04) : 643 - 652
  • [36] Quantitative evaluation of left atrial volume and function by one-dimensional, two-dimensional, and three-dimensional echocardiography in a population of normal dogs
    LeBlanc, N.
    Scollan, K.
    Sisson, D.
    JOURNAL OF VETERINARY CARDIOLOGY, 2016, 18 (04) : 336 - 349
  • [37] Assessment of left atrial myocardial deformation using two-dimensional speckle-tracking echocardiography in cats with cardiogenic and non-cardiogenic arterial thromboembolism
    Tosuwan, Jidapa
    Surachetpong, Sirilak Disatian
    Hunprasit, Vachira
    INTERNATIONAL JOURNAL OF VETERINARY SCIENCE AND MEDICINE, 2023, 11 (01) : 11 - 22
  • [38] Left Atrial Volumes and Function by Three-Dimensional Echocardiography Reference Values, Accuracy, Reproducibility, and Comparison With Two-Dimensional Echocardiographic Measurements
    Badano, Luigi P.
    Miglioranza, Marcelo H.
    Mihaila, Sorina
    Peluso, Diletta
    Xhaxho, Jola
    Marra, Martina Perazzolo
    Cucchini, Umberto
    Soriani, Nicola
    Iliceto, Sabino
    Muraru, Denisa
    CIRCULATION-CARDIOVASCULAR IMAGING, 2016, 9 (07)
  • [39] Detection and diagnosis of iatrogenic inadvertent diversion of partial inferior vena cava into the left atrium by transesophageal echocardiography during large posteroinferior surgical atrial septal defect closure
    Zhang, Yanzi
    Song, Haibo
    Qiao, Xin
    Xiao, Xijun
    Liu, Jin
    Wang, Xiao
    JOURNAL OF ANESTHESIA, 2015, 29 (03) : 442 - 445
  • [40] Quantification of left atrial contractile function using two-dimensional speckle tracking echocardiography in horses after conversion of atrial fibrillation to sinus rhythm
    Eberhardt, C.
    Schwarzwald, C. C.
    JOURNAL OF VETERINARY CARDIOLOGY, 2021, 35 : 108 - 120