Cardiac computed tomography compared with two-dimensional transesophageal echocardiography for the detection and assessment of atrial septal pouches

被引:0
|
作者
Mateusz K. Hołda
Agata Krawczyk-Ożóg
Mateusz Koziej
Wiesław Pawlik
Danuta Sorysz
Karolina Wszołek
Dariusz Dudek
Wiesława Klimek-Piotrowska
机构
[1] Jagiellonian University Medical College,HEART
[2] Jagiellonian University Medical College, Heart Embryology and Anatomy Research Team, Department of Anatomy
[3] Jagiellonian University Medical College,Department of Interventional Cardiology, University Hospital
来源
The International Journal of Cardiovascular Imaging | 2018年 / 34卷
关键词
Septal pouch; Left atrium; Interatrial septum; Patent foramen ovale; Cryptogenic stroke; MSCT;
D O I
暂无
中图分类号
学科分类号
摘要
The aim of this study is to compare the two-dimensional transesophageal echocardiography (2D-TEE) with multi-slice computed tomography (MSCT) and with autopsied material to evaluate the ability and precision of the imaging methods for the detection and assessment of septal pouch (SP). One hundred and fifty patients that underwent both 2D-TEE and MSCT and 50 autopsied human hearts were investigated. In MSCT, the interatrial septum was classified as a left SP in 37.3%, right SP in 3.3%, and patent foramen ovale (PFO) channel in 3.3%. In 2D-TEE, the interatrial septum was classified as a left SP in 39.3%, right SP in 11.3%, double SP in 4.7%, and PFO channel in 2.0%. The weighted kappa coefficient between MSCT and 2D-TEE in assessing the septum morphology was 0.59. The prevalence of the left SP is lower when it is evaluated by MSCT or 2D-TEE than by anatomical study, but this difference is insignificant (37.3% vs. 44.0%, p = 0.40, and 39.3% vs. 44.0%, p = 0.56, respectively). The prevalence of left SPs is lower when detected by MSCT or 2D-TEE than during autopsy, but the difference is statistically insignificant (37.3% vs. 44.0%, p = 0.40, and 39.3% vs. 44.0%, p = 0.56, respectively). Both 2D-TEE and MSCT are comparable techniques for detecting left-sided SPs with the insignificant lower prevalence of detecting left-sided SPs compared to autopsied material. However, TEE with the contrast seems to be superior over MSCT due to the possibility of unambiguous PFO channel detection. Therefore, TEE with contrast should be preferred over MSCT in the identification of left-sided SPs.
引用
收藏
页码:1305 / 1313
页数:8
相关论文
共 50 条
  • [21] Electrocardiography-gated dual-source computed tomography in the detection of atrial septal aneurysm
    Xie, Lixiang
    Liu, Zhongxiao
    Zhang, Xiuli
    Xu, Kai
    Xu, Qian
    Lu, Li
    Hu, Chunfeng
    Han, Shuguang
    Li, Jingjing
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2018, 16 (05) : 4260 - 4264
  • [22] Multiperforated atrial septal "aneurysm in aneurysm": Percutaneous closure guided by real-time three-dimensional transesophageal echocardiography
    Sun, Feifei
    Fan, Miao
    Li, Ying
    Ren, Weidong
    Chen, Yanli
    JOURNAL OF CLINICAL ULTRASOUND, 2018, 46 (06) : 421 - 423
  • [23] Head-to-head comparison of real-time three-dimensional transthoracic echocardiography with transthoracic and transesophageal two-dimensional contrast echocardiography for the detection of patent foramen ovale
    Monte, Ines
    Grasso, Stefania
    Licciardi, Salvatore
    Badano, Luigi P.
    EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2010, 11 (03): : 245 - 249
  • [24] Clinical value of stereoscopic three-dimensional echocardiography in assessment of atrial septal defects: Feasibility and efficiency
    Wang, Jing
    Wang, Xinfang
    Xie, Mingxing
    He, Lin
    Lv, Qing
    Wang, Lei
    JOURNAL OF HUAZHONG UNIVERSITY OF SCIENCE AND TECHNOLOGY-MEDICAL SCIENCES, 2009, 29 (06) : 791 - 794
  • [25] Incremental value of live/real time three-dimensional transesophageal echocardiography over the two-dimensional technique in the assessment of a tuberculoma involving the left atrium and appendage
    Oz, Tugba Kemaloglu
    Elsayed, Mahmoud
    Nanda, Navin C.
    Kalenderoglu, Koray
    Akyuz, Sukru
    Atasoy, Isil
    Osken, Altug
    Onuk, Tolga
    Eren, Mehmet
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2016, 33 (09): : 1409 - 1412
  • [26] Diagnostic Performance of Cardiac Computed Tomography for Detecting Patent Foramen Ovale: Evaluation Using Transesophageal Echocardiography and Catheterization as Reference Standards
    Miki, Takashi
    Nakagawa, Koji
    Ichikawa, Keishi
    Mizuno, Tomofumi
    Nakayama, Rie
    Ejiri, Kentaro
    Kawada, Satoshi
    Takaya, Yoichi
    Miyamoto, Masakazu
    Miyoshi, Toru
    Akagi, Teiji
    Ito, Hiroshi
    JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2023, 10 (05)
  • [27] Comparison of cardiac computed tomography angiography and transoesophagea echocardiography for device surveillance after left atrial appendage closure
    Qamar, Sadia R.
    Jalal, Sabeena
    Nicolaou, Savvas
    Tsang, Michael
    Gilhofer, Thomas
    Saw, Jacqueline
    EUROINTERVENTION, 2019, 15 (08) : 663 - +
  • [28] Application of Real-Time Three-Dimensional Transesophageal Echocardiography Using a Matrix Array Probe for Transcatheter Closure of Atrial Septal Defect
    Taniguchi, Manabu
    Akagi, Teiji
    Watanabe, Nobuhisa
    Okamoto, Yoshio
    Nakagawa, Koji
    Kijima, Yasufumi
    Toh, Norihisa
    Ohtsuki, Shinichi
    Kusano, Kengo
    Sano, Shunji
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2009, 22 (10) : 1114 - 1120
  • [29] The Impact of Mitral Stenosis on Left Atrial Function Assessed by Two-Dimensional Speckle Tracking Echocardiography
    Demirkol, Sait
    Kucuk, Ugur
    Baysan, Oben
    Balta, Sevket
    Celik, Turgay
    Kurt, Ibrahim Halil
    Kucuk, Hilal Olgun
    Yuksel, Uygar Cagdas
    Unlu, Murat
    Yokusoglu, Mehmet
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2012, 29 (09): : 1064 - 1070
  • [30] Comparison of Two-Dimensional Versus Real-Time Three-Dimensional Transesophageal Echocardiography for Evaluation of Patent Foramen Ovale Morphology
    Tanaka, Jun
    Izumo, Masaki
    Fukuoka, Yoko
    Saitoh, Takeji
    Harada, Kenji
    Harada, Kazumasa
    Gurudevan, Swaminatha V.
    Tolstrup, Kirsten
    Siegel, Robert J.
    Shiota, Takahiro
    AMERICAN JOURNAL OF CARDIOLOGY, 2013, 111 (07) : 1052 - 1056