In situ analysis of magnesium alloy using a standoff and double-pulse laser-induced breakdown spectroscopy system

被引:0
作者
Yong Xin
Lan-Xiang Sun
Zhi-Jia Yang
Peng Zeng
Zhi-Bo Cong
Li-Feng Qi
机构
[1] Chinese Academy of Sciences,Key Laboratory of Networked Control Systems, Shenyang Institute of Automation
[2] University of Chinese Academy of Sciences,undefined
来源
Frontiers of Physics | 2016年 / 11卷
关键词
laser-induced breakdown spectroscopy; standoff; double-pulse; online; magnesium alloy;
D O I
暂无
中图分类号
学科分类号
摘要
To monitor the components of molten magnesium alloy during the smelting process in real time and online, we designed a standoff double-pulse laser-induced breakdown spectroscopy (LIBS) analysis system that can perform focusing, collecting and imaging of long-range samples. First, we tested the system on solid standard magnesium alloy samples in the laboratory to establish a basis for the online monitoring of the components of molten magnesium alloy in the future. The experimental results show that the diameters of the focus spots are approximately 1 mm at a range of 3 m, the ablation depth of the double-pulse mode is much deeper than that of the single-pulse mode, the optimum interpulse delay of the double pulse is inconsistent at different ranges, and the spectral intensity decays rapidly as the range increases. In addition, the enhancement effect of the double pulse at 1.89 m is greater than that at 2.97 m, the maximum enhancement is 7.1-fold for the Y(I)550.35-nm line at 1.89 m, and the calibration results at 1.89 m are better than those at 2.97 m. At 1.89 m, the determination coefficients (R2) of the calibration curves are approximately 99% for Y, Pr, and Zr; the relative standard deviations (RSDs) are less than 10% for Y, Pr, and Zr; the root mean square errors (RMSEs) are less than 0.037% for Pr and Zr; the limits of detection (LODs) are less than 1000 ppm for Y, Pr, and Zr; and the LODs of Y, Pr, and Zr at 2.97 m are higher than those at 1.89 m. Additionally, we tested the system on molten magnesium alloy in a magnesium alloy plant. The calibration results of the liquid magnesium alloy are not as favorable as those of the sampling solid magnesium alloys. In particular, the RSDs of the liquid magnesium alloy are approximately 20% for Pr and La. However, with future improvements in the experimental conditions, the developed system is promising for the in situ analysis of molten magnesium alloy.
引用
收藏
相关论文
共 189 条
[1]  
Ding W. J.(2010)Research and application development of advanced magnesium alloys Materials China 29 37-undefined
[2]  
Wu Y. J.(2012)Laser-induced breakdown spectroscopy (LIBS) part II: Review of instrumental and methodological approaches to material analysis and applications to different fields, Appl. Spectrosc. 66 347-undefined
[3]  
Peng L. M.(2010)The development of fieldable laser-induced breakdown spectrometer: No limits on the horizon Spectrochim. Acta B At. Spectrosc. 65 975-undefined
[4]  
Zeng X. Q.(2012)Trace elemental analysis by laser-induced breakdown spectroscopy — Biological applications Surf. Sci. Rep. 67 233-undefined
[5]  
Lin D. L.(2014)Good practices in LIBS analysis: Review and advices Spectrochim. Acta B At. Spectrosc. 101 171-undefined
[6]  
Chen B.(2014)Algal biomass analysis by laser-based analytical techniques—A review Sensors (Basel Switzerland) 14 17725-undefined
[7]  
Hahn D. W.(2012)Assessment of LIBS for spectrochemical analysis: A review Appl. Spectrosc. Rev. 47 14-undefined
[8]  
Omenetto N.(2014)Laser-induced breakdown spectroscopy in China Front. Phys. 9 419-undefined
[9]  
Fortes F. J.(2012)Laser-induced plasma and laserinduced breakdown spectroscopy (LIBS) in China: The challenge and the opportunity Front. Phys. 7 647-undefined
[10]  
Laserna J. J.(2005)Investigation of matrix effects in laser-induced breakdown spectroscopy plasmas of high-alloy steel for matrix and minor elements Spectrochim. Acta B At. Spectrosc. 60 1083-undefined