Analysis of Twist Deformation in Wire-driven Continuum Surgical Robot

被引:1
作者
Daekeun Ji
Tae Hun Kang
Seongbo Shim
Jaesung Hong
机构
[1] Daegu Gyeongbuk Institute of Science and Technology,Department of Robotics Engineering
[2] Daegu Gyeongbuk Institute of Science and Technology,Convergence Research Center for Collaborative Robots
来源
International Journal of Control, Automation and Systems | 2020年 / 18卷
关键词
Continuum robot; minimally invasive surgery; positional accuracy; twist deformation; wire-driven mechanism;
D O I
暂无
中图分类号
学科分类号
摘要
Wire-driven continuum surgical robots are attracting significant interest in minimally invasive surgeries owing to their high dexterity level and miniaturization. However, twist deformation due to the external force at the end effector decreases the accuracy and controllability of these robots. In this study, we analyze the two factors responsible for twist deformation and propose models incorporating these factors. In our analyses, we first consider twist deformation due to the elastic deformation of the wire; when a tensioned wire is subjected to normal force, a sag effect occurs, which results in twist deformation in the robot. We analyze this sag effect statically considering the material properties of the wire. We also analyze the twist deformation due to the clearance between the wire and hole boundary in the spacer of the robot. Clearance is required in a wire-driven continuum robot to realize bending motion; however, this is considered one of the main causes of twist deformation and is referred to as the clearance effect. Subsequently, we propose sag and clearance effect models that quantitatively predict the twist deformation. The results of the experiments conducted to verify the accuracy of the proposed models, including a payload test using a conventional continuum robot comprising spherical joints, indicate that the accuracy of the proposed models is 95%.
引用
收藏
页码:10 / 20
页数:10
相关论文
共 101 条
  • [1] Petroni G(2013)A novel intracorporeal assembling robotic systern for single-port laparoscopic surgery Surgical Endoscopy 27 665-670
  • [2] Niccolini M(2013)Surgical robot system for single-port surgery with novel joint mechanism IEEE Trans, on Biomedical Engineering 60 937-944
  • [3] Menciassi A(2013)Design and coordination kinematics of an insertable robotic effectors platform for single-port access surgery IEEE/ASME Trans, on Mechatronics 18 1612-1624
  • [4] Dario P(2000)A fully autonomous microrobotic endoscopy system Journal of Intelligent & Robotic Systems 28 325-341
  • [5] Cuschieri A(2011)Modeling and control of a continuum style microrobot for endovascular surgery IEEE Trans, on Robotics 27 1024-1030
  • [6] Shin W-H(2014)A novel four-wire-driven robotic catheter for radio-frequency ablation treatment International Journal of Computer Assisted Radiology and Surgery 9 867-874
  • [7] Kwon D-S(2015)Additive manufacturing of patient-specific tubular continuum manipulators Proc. of SPIE Conf. Image-Guided Procedures, Robotic Interventions, and Modeling 9415 94151P-55
  • [8] Ding J(2006)Kinematics for multisection continuum robots IEEE Trans, on Robotics 22 43-1683
  • [9] Goldman R E(2018)Development of a novel robotic platform with controllable stiffness manipulation arms for laparoendoscopic single site surgery (LESS) The International Journal of Medical Robotics and Computer Assisted Surgery 141 e1838-354
  • [10] Xu K(2010)Design and kinematic modeling of constant curvature continuum robots: A review The International Journal of Robotics Research 29 1661-35