An amperometric uric acid biosensor based on chitosan-carbon nanotubes electrospun nanofiber on silver nanoparticles

被引:0
作者
Apon Numnuam
Panote Thavarungkul
Proespichaya Kanatharana
机构
[1] Prince of Songkla University,Trace Analysis and Biosensor Research Center
[2] Prince of Songkla University,Center of Excellence for Innovation in Chemistry, Faculty of Science
[3] Prince of Songkla University,Department of Chemistry, Faculty of Science
[4] Prince of Songkla University,Department of Physics, Faculty of Science
来源
Analytical and Bioanalytical Chemistry | 2014年 / 406卷
关键词
Uric acid biosensor; Chitosan-carbon nanotubes composite; Nanofiber; Electrospinning;
D O I
暂无
中图分类号
学科分类号
摘要
A novel amperometric uric acid biosensor was fabricated by immobilizing uricase on an electrospun nanocomposite of chitosan-carbon nanotubes nanofiber (Chi–CNTsNF) covering an electrodeposited layer of silver nanoparticles (AgNPs) on a gold electrode (uricase/Chi–CNTsNF/AgNPs/Au). The uric acid response was determined at an optimum applied potential of −0.35 V vs Ag/AgCl in a flow-injection system based on the change of the reduction current for dissolved oxygen during oxidation of uric acid by the immobilized uricase. The response was directly proportional to the uric acid concentration. Under the optimum conditions, the fabricated uric acid biosensor had a very wide linear range, 1.0–400 μmol L−1, with a very low limit of detection of 1.0 μmol L−1 (s/n = 3). The operational stability of the uricase/Chi–CNTsNF/AgNPs/Au biosensor (up to 205 injections) was excellent and the storage life was more than six weeks. A low Michaelis–Menten constant of 0.21 mmol L−1 indicated that the immobilized uricase had high affinity for uric acid. The presence of potential common interfering substances, for example ascorbic acid, glucose, and lactic acid, had negligible effects on the performance of the biosensor. When used for analysis of uric acid in serum samples, the results agreed well with those obtained by use of the standard enzymatic colorimetric method (P > 0.05).
引用
收藏
页码:3763 / 3772
页数:9
相关论文
共 123 条
  • [1] Huang SH(2004)Detection of serum uric acid using the optical polymeric enzyme biochip system Biosens Bioelectron 19 1627-1633
  • [2] Shih YC(1998)A new logic for DNA engineering using recombination in escherichia coli Nat Genet 20 123-128
  • [3] Wu CY(2006)Simultaneous voltammetric measurement of ascorbic acid, epinephrine and uric acid at a glassy carbon electrode modified with caffeic acid Biosens Bioelectron 21 1086-1092
  • [4] Yuan CJ(2010)Preparation of selective and sensitive electrochemically treated pencil graphite electrodes for the determination of uric acid in urine and blood serum Biosens Bioelectron 25 2497-2502
  • [5] Yang YS(2004)Polyaniline-uricase biosensor prepared with template process Biosens Bioelectron 19 1635-1640
  • [6] Li YK(2007)Development and analytical application of an uric acid biosensor using an uricase-immobilized eggshell membrane Biosens Bioelectron 22 1791-1797
  • [7] Wu TK(2005)Electrocatalytic reactivity for oxygen reduction of palladium modified carbon nanotubes synthesized in supercritical fluid Electrochem Commun 7 267-274
  • [8] Zhang Y(2005)Electrocatalytic reduction of oxygen by a platinum nanoparticle/carbon nanotube composite electrode J Electroanal Chem 577 295-302
  • [9] Buchholz F(2004)Application of multi-walled carbon nanotubes functionalized with hemin for oxygen detection in neutral solution J Electroanal Chem 562 241-246
  • [10] Muyrers JPP(2007)Amperometric glucose sensor based on catalytic reduction of dissolved oxygen at soluble carbon nanofiber Biosens Bioelectron 23 479-484