New automated Markov–Gibbs random field based framework for myocardial wall viability quantification on agent enhanced cardiac magnetic resonance images

被引:0
作者
Ahmed Elnakib
Garth M. Beache
Georgy Gimel’farb
Ayman El-Baz
机构
[1] University of Louisville,BioImaging Laboratory, Department of Bioengineering
[2] University of Louisville,Department of Diagnostic Radiology, School of Medicine
[3] University of Auckland,Department of Computer Science
来源
The International Journal of Cardiovascular Imaging | 2012年 / 28卷
关键词
Myocardial viability; Gadolinium; Segmentation; Contrast enhanced cardiac magnetic resonance images; Markov–Gibbs random field; Ischemic heart disease;
D O I
暂无
中图分类号
学科分类号
摘要
A novel automated framework for detecting and quantifying viability from agent enhanced cardiac magnetic resonance images is proposed. The framework identifies the pathological tissues based on a joint Markov–Gibbs random field (MGRF) model that accounts for the 1st-order visual appearance of the myocardial wall (in terms of the pixel-wise intensities) and the 2nd-order spatial interactions between pixels. The pathological tissue is quantified based on two metrics: the percentage area in each segment with respect to the total area of the segment, and the trans-wall extent of the pathological tissue. This transmural extent is estimated using point-to-point correspondences based on a Laplace partial differential equation. Transmural extent was validated using a simulated phantom. We tested the proposed framework on 14 datasets (168 images) and validated against manual expert delineation of the pathological tissue by two observers. Mean Dice similarity coefficients (DSC) of 0.90 and 0.88 were obtained for the observers, approaching the ideal value, 1. The Bland–Altman statistic of infarct volumes estimated by manual versus the MGRF estimation revealed little bias difference, and most values fell within the 95% confidence interval, suggesting very good agreement. Using the DSC measure we documented statistically significant superior segmentation performance for our MGRF method versus established intensity-based methods (greater DSC, and smaller standard deviation). Our Laplace method showed good operating characteristics across the full range of extent of transmural infarct, outperforming conventional methods. Phantom validation and experiments on patient data confirmed the robustness and accuracy of the proposed framework.
引用
收藏
页码:1683 / 1698
页数:15
相关论文
共 191 条
[21]  
Schnackenburg B(2004)Quantification of myocardial infarct size and transmurality by contrast-enhanced magnetic resonance imaging in men Am J Cardiol 94 284-138
[22]  
Delius W(1994)Magnetic resonance imaging during dobutamine stress for detection and localization of coronary artery disease quantitative wall motion analysis using a modification of the centerline method Circulation 90 127-164
[23]  
Mudra H(1989)Random field models in image analysis J Appl Stat 16 131-302
[24]  
Wolfram D(1986)On the statistical analysis of dirty pictures J R Stat Soc 48B 259-268
[25]  
Schwaiger M(1982)The Potts model Rev Mod Phys 54 235-968
[26]  
Gerber BL(2006)Precise segmentation of multi-modal images IEEE Trans Image Process 15 952-302
[27]  
Garot J(1945)Measures of the amount of ecologic association between species Ecol Soc Am 26 297-1453
[28]  
Bluemke DA(2000)The use of contrast-enhanced magnetic resonance imaging to identify reversible myocardial dysfunction N Engl J Med 43 1445-542
[29]  
Wu KC(2002)Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: a statement for healthcare professionals from the cardiac imaging committee of the council on clinical cardiology of the American heart association Circulation 105 539-1107
[30]  
Lima JA(2001)Transmural extent of acute myocardial infarction predicts long-term improvement in contractile function Circulation 104 1101-32