Tilt sensor based on intermodal photonic crystal fiber interferometer

被引:5
|
作者
Zhang X. [1 ]
Ni K. [1 ]
Zhao C. [1 ]
Ye M. [1 ]
Jin Y. [1 ]
机构
[1] Institute of Optoelectronic Technology, China Jiliang University
基金
中国国家自然科学基金;
关键词
interferometer; intermodal; photonic crystal fiber; Tilt sensors;
D O I
10.1007/s13320-014-0186-z
中图分类号
学科分类号
摘要
A tilt sensor based on an intermodal photonic crystal fiber (PCF) interferometer is demonstrated. The sensor consists of a tubular filled with NaCl aqueous solutions and an intermodal PCF interferometer, which is formed by using a short PCF with two single-mode fibers (SMFs) spliced at both ends, and the air-holes in the splice regions are fully collapsed. The intermodal PCF interferometer is fixed in a rigid glass tubular with a slant orientation, and a half of the PCF is immersed in the NaCl aqueous solutions, while the other half is exposed in air. When tilting the tubular, the length of the PCF immersed changes so that the transmission spectrum moves. Therefore, by monitoring the wavelength shift, the tilt angle can be achieved. In the experiment, a 0.8-cm-length intermodal PCF interferometer was adopted. The sensitivity of the proposed sensor was obtained from -1.5461 nm/° to -30.1244 nm/°when measuring from -35.1°to 37.05°. © 2014 The Author(s).
引用
收藏
页码:209 / 214
页数:5
相关论文
共 50 条
  • [41] High-sensitivity salinity sensor realized with photonic crystal fiber Sagnac interferometer
    Wu, Chuang
    Fu, H. Y.
    Au, H. Y.
    Guan, Bai-Ou
    Tam, H. Y.
    21ST INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS, 2011, 7753
  • [42] Detection of cancer affected cell using Sagnac interferometer based photonic crystal fiber refractive index sensor
    Md. Aslam Mollah
    Rownok Jahan Usha
    Sanjida Tasnim
    Kawsar Ahmed
    Optical and Quantum Electronics, 2020, 52
  • [43] Design and analysis of glucose sensor based on Sagnac interferometer utilizing photonic crystal fiber with micro-holes
    Liu, Yundong
    Wang, Yujun
    Li, Yingying
    Gao, Zhigang
    OPTICAL AND QUANTUM ELECTRONICS, 2024, 56 (08)
  • [44] Temperature and index insensitive strain sensor based on a photonic crystal fiber in line Mach-Zehnder interferometer
    Zheng, Jiarong
    Yan, Peiguang
    Yu, Yongqin
    Ou, Zhilong
    Wang, Jishun
    Chen, Xue
    Du, Chenlin
    OPTICS COMMUNICATIONS, 2013, 297 : 7 - 11
  • [45] Detection of cancer affected cell using Sagnac interferometer based photonic crystal fiber refractive index sensor
    Mollah, Md. Aslam
    Usha, Rownok Jahan
    Tasnim, Sanjida
    Ahmed, Kawsar
    OPTICAL AND QUANTUM ELECTRONICS, 2020, 52 (09)
  • [46] High-Sensitivity MF Filled Photonic Crystal Fiber Magnetic Field Sensor Based on Sagnac Interferometer
    Fan, Zhenkai
    Liu, Haishan
    Chen, Hailiang
    Chu, Shichao
    Li, Shuguang
    Zhang, Yinping
    JOURNAL OF SUPERCONDUCTIVITY AND NOVEL MAGNETISM, 2024, 37 (8-10) : 1411 - 1419
  • [47] Sensitivity analysis of refractive index measurement based on intermodal interference in photonic crystal fiber
    Hou Jian-Ping
    Ning Tao
    Gai Shuang-Long
    Li Peng
    Hao Jian-Ping
    Zhao Jian-Lin
    ACTA PHYSICA SINICA, 2010, 59 (07) : 4732 - 4737
  • [48] A Novel Mach–Zehnder Interferometer Based on Hybrid Liquid Crystal–Photonic Crystal Fiber
    罗先萍
    王斐儒
    陈春雷
    张伶莉
    王雷
    孙伟民
    刘永军
    Chinese Physics Letters, 2017, (12) : 41 - 44
  • [49] Intensity curvature sensor based on photonic crystal fiber with three coupled cores
    Martins, H.
    Marques, Manuel B.
    Jorge, Pedro
    Cordeiro, Cristiano M. B.
    Frazao, Orlando
    OPTICS COMMUNICATIONS, 2012, 285 (24) : 5128 - 5131
  • [50] Temperature Sensor Based on Photonic Crystal Fiber Filled With Liquid and Silver Nanowires
    Yang, X. C.
    Lu, Y.
    Liu, B. L.
    Yao, J. Q.
    IEEE PHOTONICS JOURNAL, 2016, 8 (03):