Natural period and vertical distribution of base shear in confined masonry buildings using ambient vibration test

被引:0
作者
Pranav Chakra-Varthy
Dhiman Basu
机构
[1] Indian Institute of Technology Gandhinagar,Department of Civil Engineering
来源
Bulletin of Earthquake Engineering | 2021年 / 19卷
关键词
Confined masonry building; Natural period; Damping ratio; Base shear distribution; Ambient vibration test; Merging strategy of sensors;
D O I
暂无
中图分类号
学科分类号
摘要
In semi-urban setting where availability of land can afford construction of low-rise buildings, confined masonry may compete with other alternatives of seismic resilient system provided well-articulated design standards and construction guidelines are available. Most seismic standards do not make explicit recommendations on the natural period and vertical distribution of base shear for the design of confined masonry buildings. In such a case, one of the two alternatives, such as (1) reinforced concrete (RC) frame building with masonry infill walls and (2) RC frame building with structural walls, is tacitly extrapolated. This paper is first aimed to explore the possible recommendations from the ambient vibration testing of a class of confined masonry building stock. Nine (G + 3) confined masonry hostel buildings are considered for Ambient Vibration Testing (AVT). Recorded signatures are processed and modal characteristics (primarily restricted to the first triplet of fundamental modes) are extracted. Each building is modelled numerically and fine-tuned followed by a comparison of natural frequencies and mode shapes in numerical model and experimental results. The fine-tuned numerical models are analysed against a set of recorded ground motions. Possible design recommendations for natural period and distribution of base shear along the height are the key contributions. Empirical equation for natural periods is derived from the seismic code recommendation on that of reinforced concrete (RC) buildings but removing the bias contributed from the height shorter than one storey while using the experimental results. Distribution of the base shear along the height follows a parabolic profile with an exponent close to 0.4. Results of AVT indicate the inherent damping ratio on an average of about 5% which, however, may not be directly used for seismic excitation. The building stock used for AVT in this paper does not include considerable variations in height and different varieties of confined masonry constructions. Therefore, recommendations of this paper should be verified against a larger size of dispersed building stock.
引用
收藏
页码:1851 / 1899
页数:48
相关论文
共 64 条
[1]  
Astroza M(2012)Seismic performance of engineered masonry buildings in the 2010 Maule earthquake Earthq Spectra 28 S385-S406
[2]  
Moroni O(2012)Ambient modal identification of a primary–secondary structure by Fast Bayesian FFT method Mech Syst Signal Process 28 280-296
[3]  
Brzev S(2019)Back-of-the-Envelope analysis of plan-asymmetric confined masonry buildings for force-based seismic design J Build Eng 21 455-467
[4]  
Tanner J(2017)On the design of a dense array to extract rotational components of earthquake ground motion Bull Earthq Eng 15 827-860
[5]  
Au S-K(2018)Revisiting probabilistic seismic hazard analysis of gujarat: an assessment of indian design spectra Nat Hazards 91 1127-1164
[6]  
Zhang F-L(2001)Modal identification of output-only systems using frequency domain decomposition Smart Mater Struct 10 441-2018
[7]  
Basu D(2010)Ambient vibration re-testing and operational modal analysis of the Humber Bridge Eng Struct 32 2003-1015
[8]  
Basu D(2008)Dynamic testing of Alfred Zampa memorial bridge J Struct Eng ASCE 134 1006-165
[9]  
Whittaker AS(2005)Dynamic identification of a masonry building using forced vibration tests Eng Struct 27 155-976
[10]  
Constantinou MC(2016)The central role played by structural design in enabling the construction of buildings that advanced and revolutionized architecture Constr Build Mater 114 956-212