Dose Verification for Tumor Motion with Different Treatment Planning Systems: A Dynamic Thorax Phantom Study

被引:0
作者
Shih-Neng Yang
Chun-Wei Lin
Mu-Bai Chang
Geoffrey G. Zhang
Kuei-Ting Chou
Yu-Rou Chiou
Shung-Shung Sun
Louis Lui
Tsung-Jung Ho
Tzung-Chi Huang
机构
[1] China Medical University,Department of Biomedical Imaging and Radiological Science
[2] China Medical University Hospital,Department of Radiation Oncology
[3] Cathay General Hospital,Department of Radiation Oncology
[4] Tainan Municipal An-Nan Hospital,Department of Radiation Oncology
[5] Moffitt Cancer Center,Department of Radiation Oncology
[6] China Medical University Hospital,Department of Nuclear Medicine and PET Center
[7] China Medical University,College of Chinese Medicine
[8] Asia University,Department of Bioinformatics and Medical Engineering
来源
Journal of Medical and Biological Engineering | 2018年 / 38卷
关键词
Four-dimensional computed tomography; Maximum-intensity projection; Respiratory motion; Dose verification;
D O I
暂无
中图分类号
学科分类号
摘要
During radiation therapy for lung cancer, the respiratory motion of the target increases error and affects the treatment outcome. A four-dimensional computed tomography (4D-CT) technology developed recently can be used to obtain snapshot thoracic CT images during the entire respiratory cycle, which can be helpful in visualization of the tumor displacement in respiratory motion. This study employed a dynamic phantom to simulate tumor respiratory motion, with motion amplitudes of 2, 5 and 10 mm in the superior-inferior direction and motion periods of 4 and 6 s. 4D-CT imaging was applied to record the movement of the target, and maximum-intensity projection (MIP) imaging was used to define the internal target volume (ITV). Treatment plans were generated using three different treatment techniques—tomotherapy, intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT). In addition, using interchangeable insert modules (an ionization chamber for point dose measurement and Gafchromic EBT3 film for planar dose distribution) in the dynamic phantom, the dose received by the target was measured. The dose received with motion was compared with that received under stationary conditions for dose errors due to respiratory motion. The point dose differences between moving and stationary conditions for tomotherapy, IMRT and VMAT were 0.48 ± 0.51%, 0.17 ± 0.45%, and 0.68 ± 0.70%, respectively; and at motion amplitudes of 2, 5, and 10 mm, the mean dose differences were 0.27 ± 0.38%, 0.37 ± 0.55% and 0.68 ± 0.74%, respectively. Based on planar dose analysis, at motion amplitudes of 2 and 5 mm, the dose distribution differences between moving and stationary conditions using the three treatment methods were all very small, and all passed the gamma index test with a criterion of 3%/3 mm, while at an amplitude of 10 mm, the edge of the ITV was associated with significantly greater dose errors. As studies have shown that in only approximately 10% of pulmonary tumors move with an amplitude >10 mm, 4D-CT MIP imaging in combination with delineation of the ITV may resolve the issue of dose error in most cases. For tumors with large motion amplitudes due to respiration, respiratory gating method may be used to reduce healthy lung tissues inside treatment field.
引用
收藏
页码:46 / 54
页数:8
相关论文
共 30 条
  • [21] Four-dimensional dose reconstruction system for lung cancer VMAT treatment: a 4D phantom study
    Hashimoto, M.
    Ito, Y.
    Tanaka, Y.
    Nakano, Masahiro
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2023, 21 (03): : 467 - 474
  • [22] Scanned proton radiotherapy for mobile targets-the effectiveness of re-scanning in the context of different treatment planning approaches and for different motion characteristics
    Knopf, Antje-Christin
    Hong, Theodore S.
    Lomax, Antony
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (22) : 7257 - 7271
  • [23] 4D computed tomography scans for conformal thoracic treatment planning: is a single scan sufficient to capture thoracic tumor motion?
    Tseng, Yolanda D.
    Wootton, Landon
    Nyflot, Matthew
    Apisarnthanarax, Smith
    Rengan, Ramesh
    Bloch, Charles
    Sandison, George
    St James, Sara
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (02)
  • [24] 4D Monte Carlo dose calculations for pre-treatment quality assurance of VMAT SBRT: a phantom-based feasibility study
    Roberts, Natalia F.
    Williams, Matthew
    Holloway, Lois
    Metcalfe, Peter
    Oborn, Bradley M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (21)
  • [25] Correlation Between CT-Simulator and Dynamic Magnetic Resonance Images in Determining The Location of Gross Tumor Volume in Radiotherapy Treatment Planning for Lung Cancer
    Nasir, Sevecen Seyhun
    Yurt, Aysegul
    Karabay, Nuri
    Umay, Cenk
    Aydin, Barbaros
    Demiral, Ayse Nur
    JOURNAL OF BASIC AND CLINICAL HEALTH SCIENCES, 2019, 3 (01): : 22 - 29
  • [26] Imaging and dosimetric errors in 4D PET/CT-guided radiotherapy from patient-specific respiratory patterns: a dynamic motion phantom end-to-end study
    Bowen, S. R.
    Nyflot, M. J.
    Herrmann, C.
    Groh, C. M.
    Meyer, J.
    Wollenweber, S. D.
    Stearns, C. W.
    Kinahan, P. E.
    Sandison, G. A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (09) : 3731 - 3746
  • [27] Dynamic gating window technique for the reduction of dosimetric error in respiratory-gated spot-scanning particle therapy: An initial phantom study using patient tumor trajectory data
    Miyamoto, Naoki
    Yokokawa, Kouhei
    Takao, Seishin
    Matsuura, Taeko
    Tanaka, Sodai
    Shimizu, Shinichi
    Shirato, Hiroki
    Umegaki, Kikuo
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (04): : 13 - 21
  • [28] The first implementation of IMRT technique for head & neck and prostate cancer patients in public sector in Greece: feasibility, treatment planning and dose delivery verification using the delta4PT Pre-Treatment volumetric quality assurance system
    Kouloulias, Vassilis
    Antypas, Christos
    Liakouli, Zoi
    Armpilia, Christina
    Zygogianni, Anna
    Floros, Ioannis
    Tolia, Maria
    Kokakis, John
    Kouvaris, John
    JOURNAL OF BUON, 2015, 20 (01): : 196 - 205
  • [29] Quantification of incidental dose to potential clinical target volume (CTV) under different stereotactic body radiation therapy (SBRT) techniques for non-small cell lung cancer - Tumor motion and using internal target volume (ITV) could improve dose distribution in CTV
    Jin, Jian-Yue
    Ajlouni, Munther
    Chen, Qing
    Kong, Feng-Ming
    Ryu, Samuet
    Movsas, Benjamin
    RADIOTHERAPY AND ONCOLOGY, 2007, 85 (02) : 267 - 276
  • [30] Evaluation of different CT maps for attenuation correction and segmentation in static 99mTc-MAA SPECT/CT for 90Y radioembolization treatment planning: A simulation study
    Lu, Zhonglin
    Chen, Gefei
    Lin, Kuan-Heng
    Wu, Tung-Hsin
    Mok, Greta S. P.
    MEDICAL PHYSICS, 2021, 48 (07) : 3842 - 3851