Position and Angular Misalignment Analysis for Implantable Wireless Power Transfer System Based on Magnetic Resonance

被引:0
作者
Fei-Xiang Gong
Zhiqiang Wei
Haokun Chi
Bo Yin
Ying Sun
Yanping Cong
Mingui Sun
机构
[1] Ocean University of China,School of Information Science and Engineering
[2] University of Pittsburgh,Department of Neurological Surgery
[3] Hebei University of Technology,School of Electrical Engineering
来源
Journal of Medical and Biological Engineering | 2017年 / 37卷
关键词
Position and angular misalignment; Magnetic resonance; Wireless power transfer; Transfer efficiency;
D O I
暂无
中图分类号
学科分类号
摘要
As a widely-acknowledged truth, the interval of human tissue, the breathing activity, and the body motion work together to change the relative position of the antenna. This knowledge, with detailed examination, is going to bring significant change to the transmission efficiency in the implementation of human wireless power transfer. This paper focused on the relationship of the transfer efficiency with lateral distance, vertical distance and angular (around the center and along the edge) misalignment. A new formula, which serves to connect the geometrical parameters both with the self-resonance frequency and with the Q-factor of the printed circuit board antenna, was given. Furthermore, the paper gave a significant analysis of the efficiency with lateral distance change, vertical distance change and two kinds of angular misalignments using finite element method. The experimental results showed that in the situation of vertical distance change and angular (along the edge) misalignment, the transmission efficiency drops rapidly with the displacement of antenna. However, in the situation of lateral distance change and angular (along the edge) misalignment, there were a high-efficiency distance—the lateral misalignment ≤40% of the length of the width in the lateral misalignment; and a high-efficiency angle—angular around the center misalignment ≤30º in the angular misalignment. Within the ranges, a high-efficiency space (HES) is formed in the implantable WPT system utility, and the transmission efficiency drops rapidly when the antenna is beyond the HES. This paper can provide a practical application to the antenna design and specific implementation in human implantable WPT system.
引用
收藏
页码:602 / 611
页数:9
相关论文
共 58 条
  • [1] Bashirullah R(2010)Wireless implants IEEE Microwave Magazine 11 S14-S23
  • [2] Yakovlev A(2012)Implantable biomedical devices: wireless powering and communication IEEE Communications Magazine 50 152-159
  • [3] Kim S(2011)Wearable and implantable wireless sensor network solutions for healthcare monitoring Sensors 11 5561-5595
  • [4] Poon A(2014)Application of wireless power transmission systems in wireless capsule endoscopy: an overview Sensors 14 10929-10951
  • [5] Darwish A(2010)An RFID-based closed-loop wireless power transmission system for biomedical applications IEEE Transactions on Circuits and Systems II: Express Briefs 57 260-264
  • [6] Hassanien AE(2009)Maximum efficiency analysis and design of self-resonance coupling coils for wireless power transmission system Proceedings of the Csee 29 21-26
  • [7] Basar MR(2008)Efficient wireless non-radiative mid-range energy transfer Annals of Physics 323 34-48
  • [8] Ahmad MY(2012)A wireless magnetic resonance energy transfer system for micro implantable medical sensors Sensors 12 10292-10308
  • [9] Cho J(2009)Magnetic resonant coupling as a potential means for wireless power transfer to multiple small receivers IEEE Transactions on Power Electronics 24 1819-1825
  • [10] Ibrahim F(2011)Design and optimization of resonance-based efficient wireless power delivery systems for biomedical implants IEEE Transactions on Biomedical Circuits and Systems 5 48-63