Corrosion rate of steel in concrete: evaluation of confinement techniques for on-site corrosion rate measurements

被引:0
作者
Peter V. Nygaard
Mette R. Geiker
Bernhard Elsener
机构
[1] FORCE Technology,Department of Civil Engineering
[2] Technical University of Denmark (DTU),undefined
[3] ETH Zurich,undefined
[4] Institute for Building Materials,undefined
[5] ETH Hönggerberg,undefined
来源
Materials and Structures | 2009年 / 42卷
关键词
Confinement; Polarisation resistance; Corrosion rate; Reinforcement corrosion; Reinforced concrete;
D O I
暂无
中图分类号
学科分类号
摘要
Earlier on-site investigations and laboratory studies have shown that varying corrosion rates are obtained when different commercially available instruments are used. The different confinement techniques, rather than the different electrochemical techniques used in the instruments, are considered to be the main reason for the discrepancies. This paper presents a method for the quantitative assessment of confinement techniques. The assessment is based on monitoring the operation of the corrosion rate instrument and following the current distribution between the electrode assembly on the concrete surface and a segmented reinforcement bar embedded in the concrete. The applicability of the method was demonstrated for two commercially available corrosion rate instruments based on different confinement techniques. The method provided an explanation of the differences in performance of the two instruments. Correlated measurements of linear polarisation resistance and macro-cell currents allowed the determination of calibration factors. Both instruments overestimated the corrosion rate of passive reinforcement, but underestimated the corrosion rate of reinforcement with intense localised corrosion.
引用
收藏
页码:1059 / 1076
页数:17
相关论文
共 55 条
[1]  
Elsener B(2003)Half-cell potential measurements—potential mapping on reinforced concrete structures, RILEM TC 154-EMC Mater Struct 36 461-471
[2]  
Andrade C(2004)Test methods for on-site corrosion rate measurement of steel reinforcement in concrete by means of the polarization resistance method Mater Struct 37 623-642
[3]  
Gulikers J(1957)Electrochemical polarization, I. A theoretical analysis of the shape of polarization curves J Electrochem Soc 104 56-63
[4]  
Polder R(1980)Corrosion of reinforcing bars in carbonated concrete Br Corros J 15 135-139
[5]  
Andrade C(1992)Practical field measurement of reinforcement corrosion in concrete using linear polarisation methods Br J NDT 34 444-452
[6]  
Alonso C(1981)Use of AC impedance in studies on steel in concrete in immersed conditions Br Corros J 16 102-106
[7]  
Gulikers J(2005)Corrosion rate of steel in concrete—measurements beyond the Tafel law Corros Sci 47 3019-3033
[8]  
Polder R(1978)Quantitative measurements of corrosion rate of reinforcing steels embedded in concrete using polarization resistance measurements Werkstoffe und Korrosion 29 515-519
[9]  
Cigna R(1995)Corrosion rate on reinforced concrete structures determined by electrochemical methods Mater Sci Forum 192–194 857-866
[10]  
Vennesland Ø(1992)Comparison of corrosion rate-measuring devices for determining corrosion rate of steel-in-concrete systems Corrosion 48 871-880