Machine learning model and strategy for fast and accurate detection of leaks in water supply network

被引:0
作者
Fan X. [1 ]
Zhang X. [2 ]
Yu X. [3 ]
机构
[1] Department of Civil and Environmental Engineering, Case Western Reserve University, 2104 Adelbert Road, Bingham 248, Cleveland, 44106-7201, OH
[2] Department of Civil and Environmental Engineering, Case Western Reserve University, 2104 Adelbert Road, Bingham 249C, Cleveland, 44106-7201, OH
[3] Department of Civil and Environmental Engineering, Case Western Reserve University, 2104 Adelbert Road, Bingham 206, Cleveland, 44106-7201, OH
来源
Journal of Infrastructure Preservation and Resilience | 2021年 / 2卷 / 01期
基金
美国国家科学基金会;
关键词
Artificial intelligence; Artificial neural network; Autoencoder neural network; Leak detection; Machine learning; Water supply network;
D O I
10.1186/s43065-021-00021-6
中图分类号
学科分类号
摘要
The water supply network (WSN) is subjected to leaks that compromise its service to the communities, which, however, is challenging to identify with conventional approaches before the consequences surface. This study developed Machine Learning (ML) models to detect leaks in the WDN. Water pressure data under leaking versus non-leaking conditions were generated with holistic WSN simulation code EPANET considering factors such as the fluctuating user demands, data noise, and the extent of leaks, etc. The results indicate that Artificial Neural Network (ANN), a supervised ML model, can accurately classify leaking versus non-leaking conditions; it, however, requires balanced dataset under both leaking and non-leaking conditions, which is difficult for a real WSN that mostly operate under normal service condition. Autoencoder neural network (AE), an unsupervised ML model, is further developed to detect leak with unbalanced data. The results show AE ML model achieved high accuracy when leaks occur in pipes inside the sensor monitoring area, while the accuracy is compromised otherwise. This observation will provide guidelines to deploy monitoring sensors to cover the desired monitoring area. A novel strategy is proposed based on multiple independent detection attempts to further increase the reliability of leak detection by the AE and is found to significantly reduce the probability of false alarm. The trained AE model and leak detection strategy is further tested on a testbed WSN and achieved promising results. The ML model and leak detection strategy can be readily deployed for in-service WSNs using data obtained with internet-of-things (IoTs) technologies such as smart meters. © The Author(s) 2021.
引用
收藏
相关论文
共 50 条
  • [1] Abokifa A.A., Haddad K., Et al., Real-time identification of cyber-physical attacks on water distribution systems via machine learning–based anomaly detection techniques, J Water Resour Plan Manag, 145, 1, (2018)
  • [2] Adedeji K.B., Hamam Y., Abe B.T., Abu-Mahfouz A.M., Towards achieving a reliable leakage detection and localization algorithm for application in water piping networks: an overview, IEEE Access, 5, pp. 20272-20285, (2017)
  • [3] Amran T.S.T., Ismail M.P., Et al., Detection of underground water distribution piping system and leakages using ground penetrating radar (GPR), AIP Conference Proceedings, (2017)
  • [4] Bakker M., Vreeburg J., Et al., A fully adaptive forecasting model for short-term drinking water demand, Environ Model Softw, 48, pp. 141-151, (2013)
  • [5] Bimpas M., Amditis A., Uzunoglu N., Detection of water leaks in supply pipes using continuous wave sensor operating at 2.45 GHz, J Appl Geophys, 70, 3, pp. 226-236, (2010)
  • [6] Braun M., Piller O., Deuerlein J., Mortazavi I., Limitations of demand-and pressure-driven modeling for large deficient networks, Drinking Water Eng Sci, 10, 2, pp. 93-98, (2017)
  • [7] Buch N., Velastin S.A., Orwell J., A review of computer vision techniques for the analysis of urban traffic, IEEE Trans Intell Transp Syst, 12, 3, pp. 920-939, (2011)
  • [8] Butler D., Leakage Detection and Management: A Comprehensive Guide to Technology and Practice in the Water Supply Industry, (2000)
  • [9] Caputo A.C., Pelagagge P.M., Using neural networks to monitor piping systems, Process Saf Prog, 22, 2, pp. 119-127, (2003)
  • [10] Chan T.K., Chin C.S., Zhong X., Review of current technologies and proposed intelligent methodologies for water distributed network leakage detection, IEEE Access, 6, pp. 78846-78867, (2018)