Physics-based, data-driven approach for predicting natural ventilation of residential high-rise buildings

被引:0
作者
Vincent J. L. Gan
Boyu Wang
C. M. Chan
A. U. Weerasuriya
Jack C. P. Cheng
机构
[1] National University of Singapore,Department of Building, School of Design and Environment
[2] The Hong Kong University of Science and Technology,Department of Civil and Environmental Engineering
来源
Building Simulation | 2022年 / 15卷
关键词
computational fluid dynamics; data-driven prediction; machine learning; multizone model; natural ventilation; residential building;
D O I
暂无
中图分类号
学科分类号
摘要
Natural ventilation is particularly important for residential high-rise buildings as it maintains indoor human comfort without incurring the energy demands that air-conditioning does. To improve a building’s natural ventilation, it is essential to develop models to understand the relationship between wind flow characteristics and the building’s design. Significantly more effort is still needed for developing such reliable, accurate, and computationally economical models instead of currently the most popular physics-based models such as computational fluid dynamics (CFD) simulation. This paper, therefore, presents a novel model developed based on physics-based modelling and a data-driven approach to evaluate natural ventilation in residential high-rise buildings. The model first uses CFD to simulate wind pressures on the exterior surfaces of a high-rise building. Once the surface pressures have been obtained, multizone modelling is used to predict the air change per hour (ACH) for different flats in various configurations. Data-driven prediction models are then developed using data from the simulation and deep neural networks that are based on mean absolute error, mean absolute percentage error, and a fusion algorithm respectively. These data-driven models are used to predict the ACH of 25 flats. The results from multizone modelling and data-driven modelling are compared. The results imply a high accuracy of the data-driven prediction in comparison with physics-based models. The fusion algorithm-based neural network performs best, achieving 96% accuracy, which is the highest of all models tested. This study contributes a more efficient and robust method for predicting wind-induced natural ventilation. The findings describe the relationship between building design (e.g., plan layout), distribution of surface pressure, and the resulting ACH, which serve to improve the practical design of sustainable buildings.
引用
收藏
页码:129 / 148
页数:19
相关论文
共 117 条
  • [1] Ai ZT(2014)Determination of single-sided ventilation rates in multistory buildings: Evaluation of methods Energy and Buildings 1 292-300
  • [2] Mak CM(2007)A comparison between CFD and Network models for predicting wind-driven ventilation in buildings Building and Environment 1 4079-4085
  • [3] Asfour OS(2007)CFD simulation of the atmospheric boundary layer: wall function problems Atmospheric Environment 1 238-252
  • [4] Gadi MB(2018)LES over RANS in building simulation for outdoor and indoor applications: A foregone conclusion? Building Simulation 1 821-870
  • [5] Blocken B(2018)Prediction of wind pressure coefficients on building surfaces using artificial neural networks Energy and Buildings 1 1429-1441
  • [6] Stathopoulos T(2009)Ventilation performance prediction for buildings: A method overview and recent applications Building and Environment 1 848-858
  • [7] Carmeliet J(2003)Prediction of pressure coefficients on roofs of low buildings using artificial neural networks Journal of Wind Engineering and Industrial Aerodynamics 1 423-441
  • [8] Blocken B(2020)Transfer learning with deep neural networks for model predictive control of HVAC and natural ventilation in smart buildings Journal of Cleaner Production 1 119866-1158
  • [9] Bre F(2011)CFD simulations of natural ventilation behaviour in high-rise buildings in regular and staggered arrangements at various spacings Energy and Buildings 1 1149-2072
  • [10] Gimenez JM(2009)Turbulence effects on the discharge coefficient and mean flow rate of wind-driven cross-ventilation Building and Environment 1 2064-312