Chemometrics-assisted electrochemical determination of dextromethorphan hydrobromide and phenylephrine hydrochloride by carbon paste electrode

被引:0
作者
Yasaman Sefid-Sefidehkhan
Maryam Khoshkam
Mandana Amiri
机构
[1] University of Mohaghegh Ardabili,Department of Chemistry
来源
Chemical Papers | 2021年 / 75卷
关键词
Voltammetry; Phenylephrine; Dextromethorphan; MCR-ALS; Equality constraint;
D O I
暂无
中图分类号
学科分类号
摘要
In this paper, multivariate curve resolution-alternating least squares (MCR-ALS) was applied for simultaneous determination of phenylephrine (PHE) and dextromethorphan (DEX) at the surface of bare carbon paste electrode (CPE). PHE and DEX are present in most the cold pharmaceuticals, and their voltammetric peaks have a high overlap that makes difficult or impossible their simultaneous electrochemical determinations without further experiments like modification of electrode, applying analytical techniques other than differential pulse voltammetry (DPV), or cyclic voltammetry. In this study, DEX and PHE were quantified on the surface of CPE without any further purification or modification. After recording DPV signals from thirty-three samples from these drugs and correcting potential shifts, MCR-ALS was applied to resolve overlapped peaks of these pharmaceuticals and quantitative determination of them in mixtures. Equality constraint was applied as a constraint during optimization and led to unique results from MCR-ALS. This study is the first report of using equality constraint in the analysis of first-order electrochemical data. The detection limit was determined, which was 1.79 μM for DEX and 1.93 μM for PHE, respectively. The main advantages of this method are its simplicity, low cost, and its speed since there is no need to modify electrode.
引用
收藏
页码:6565 / 6573
页数:8
相关论文
共 190 条
  • [1] Abou Al-Alamein AM(2019)Green HPTLC-densitometric approach for simultaneous determination and impurity- profiling of ebastine and phenylephrine hydrochloride Microchem J 147 1097-1102
  • [2] Abd El-Rahman MK(2019)Chemometrics-assisted voltammetric determination of timolol maleate and brimonidine tartrate utilizing a carbon paste electrode modified with iron (III) oxide nanoparticles Microchem J 145 313-329
  • [3] Abdel-Moety EM(2013)A systematic study on the accuracy of chemical quantitative analysis using soft modeling methods Chemom Intell Lab Syst 120 59-70
  • [4] Fawaz EM(2015)Multivariate calibration of first-order data with the correlation constrained MCR-ALS method Chemom Intell Lab Syst 142 143-150
  • [5] Abou Al Alamein AM(2018)Colorimetric determination of phenylephrine hydrochloride drug Using 4-Aminoantipyrine: Stability and higher sensitivity J Pharm Sci Res 10 1774-1779
  • [6] Hendawy HAM(2019)Determination of phenylephrine hydrochloride and Amoxicillin in binary mixture using derivative Spectrophotometry methods Int J Pharm Qual Assur 10 168-177
  • [7] Elabd NO(2019)Simultaneous spectrophotometric determination of phenylephrine hydrochloride and amoxicillin via derivative spectrophotometry Int J Drug Deliv Technol 9 500-506
  • [8] Ahmadi G(2016)Determination of dextromethorphan in oral fluid by LC–MS-MS J Anal Toxicol 40 360-366
  • [9] Abdollahi H(2007)Spectrophotometric determination of pipazethate HCl, dextromethorphan HBr and drotaverine HCl in their pharmaceutical preparations Spectrochim Acta Part A: Mol Biomol Spectrosc 67 1088-1093
  • [10] Ahmadi G(2012)Simultaneous voltammetric determination of uric acid and ascorbic acid using carbon paste/cobalt Schiff base composite electrode J Solid State Electrochem 16 2187-2195