Amperometric Detection of Pesticides Using Polymer Electrodes

被引:0
作者
Dipankar Ghosh
Kakoli Dutta
Dipankar Bhattacharyay
Priyabrata Sarkar
机构
[1] University of Calcutta,Department of Polymer Science and Technology
来源
Environmental Monitoring and Assessment | 2006年 / 119卷
关键词
amperometric; biosensor; pesticide; polyacrylamide; screen-printed electrode;
D O I
暂无
中图分类号
学科分类号
摘要
The real time monitoring of some organophosphorus based pesticides is of great concern to environmentalists because the widespread use of pesticides is causing severe health hazards to all living beings and also hampering our ecological balance. The traditional methods of measurement of pesticide residues are time consuming, need sample pre-treatment, and lack desired specificity and accuracy. We have developed an amperometric biosensor for indirect measurement of the pesticide concentration precisely in ppb level. The method is based on the action of two enzymes namely acetylcholine esterase and choline oxidase which are uniquely immobilized in a polymeric porous network directly on the working electrode of a screen-printed sensor. Polyacrylamide matrix has been prepared by copolymerisation of acrylamide andN,N′-methylenebisacrylamide using Potassium peroxodisulphate (K2S2O8) as initiator. A linear relationship was obtained between the range of 0 to 10 ppb.
引用
收藏
页码:481 / 489
页数:8
相关论文
共 29 条
  • [1] Albareda-Sirvent M.(2001)Pesticide determination in tap water and juice samples using disposable amperometric biosensors made using thick-film technology Analytica Chimica Acta 442 35-44
  • [2] Merkoci A.(1995)Evaluation of the use of Free and immobilized Acetyl Cholinesterase for PARAOXON detection with an amperometric choline oxidase based biosensor Analytical Chimica Acta 311 273-280
  • [3] Alegret S.(2000)Acetylcholine biosensor involving entrapment of acetylcholinesterase and poly(ethylene glycol)-modified choline oxidase in a poly(vinyl alcohol) cryogel membrane Enzyme and Microbial Technology 27 279-285
  • [4] Cremisini C.(2002)Construction of an acetylcolinesterase-choline oxidase biosensor for aldicarb determination Biosensors and Bioelectronics 17 531-539
  • [5] Di S.(2001)Disposable cholinesterase biosensor for the detection of pesticides in water-miscible organic solvents Analytica Chimica Acta 431 231-237
  • [6] Sario J.(1999)Evaluation of a Highly sensitive amperometric biosensor with low cholinesterase charge immobilized on a chemically modified carbon paste electrode for trace determination of carbamates in fruit, vegetable and water samples Analytica Chimica Acta 399 37-49
  • [7] Mela R.(2004)Development of urease and glutamic dehydrogenase Amperometric assay for heavy metals screening in polluted samples Biosensors and Bioelectronics 19 1157-1167
  • [8] Pilloton G.(undefined)undefined undefined undefined undefined-undefined
  • [9] Palleschi L.(undefined)undefined undefined undefined undefined-undefined
  • [10] Doretti D.(undefined)undefined undefined undefined undefined-undefined