Development of a centrifugal blood pump with magnetically suspended impeller and the related fluid mechanical problems

被引:3
|
作者
T Akamatsu
T Tsukiya
机构
[1] Setsunan University,Department of Mechanical Engineering
[2] Kyoto University,Department of Mechanical Engineering
来源
Sadhana | 1998年 / 23卷
关键词
Centrifugal pump; magnetically suspended impeller; viscous effect; impeller disk; whirl motion of impeller; flow pattern;
D O I
暂无
中图分类号
学科分类号
摘要
This paper deals with fluid mechanical problems encountered in eight years of developmental studies on a centrifugal blood pump with magnetically suspended impeller. The main results of the investigation are as follows. The impeller disk friction is dominant among all the power losses; the magnetically suspended impeller with radial straight vanes is the most stable. Motor current depends on blood viscosity and flow rate. Consequently, the flow rate and pressure difference can be estimated by self-sensing without any need for flowmeter and pressure transducers.
引用
收藏
页码:597 / 603
页数:6
相关论文
共 50 条
  • [41] In vivo and in vitro evaluation of the pulsatile mode of a magnetically suspended centrifugal pump
    Kono, S
    Nishimura, K
    Yamada, T
    Oonishi, T
    Tsukiya, T
    Akamatsu, T
    Ban, T
    ASAIO JOURNAL, 1997, 43 (05) : M580 - M584
  • [42] A new magnetically suspended centrifugal pump: In vitro and preliminary in vivo assessment
    Park, CH
    Nishimura, K
    Akamatsu, T
    Tsukiya, T
    Matsuda, K
    Ban, T
    ARTIFICIAL ORGANS, 1996, 20 (02) : 128 - 131
  • [43] THE EFFECT OF SHEAR STRESS ON THE IMPELLER DESIGN OF CENTRIFUGAL BLOOD PUMP
    Mondee, Kamonwan
    Foojinphan, Nutchanant
    Wannawat, Praemai
    Naiyanetr, Phornphop
    2016 9TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON), 2016,
  • [44] Effects of blade geometry on centrifugal blood pump impeller performance
    Chan, WK
    Ng, BTH
    Yu, SCM
    Chua, LP
    Wong, YW
    IEEE-EMBS ASIA PACIFIC CONFERENCE ON BIOMEDICAL ENGINEERING - PROCEEDINGS, PTS 1 & 2, 2000, : 583 - 584
  • [45] Numerical Study of a Centrifugal Blood Pump With Different Impeller Profiles
    Song, Guoliang
    Chua, Leok Poh
    Lim, Tau Meng
    ASAIO JOURNAL, 2010, 56 (01) : 24 - 29
  • [46] Visualization study of the transient flow in the centrifugal blood pump impeller
    Tsukiya, T
    Taenaka, Y
    Tatsumi, E
    Takano, H
    ASAIO JOURNAL, 2002, 48 (04) : 431 - 436
  • [47] Hemolytic effect of surface roughness of an impeller in a centrifugal blood pump
    Department of Surgery, Baylor College of Medicine, Houston, TX, United States
    不详
    ARTIF. ORGANS, 7 (686-690):
  • [48] The CentriMag: A new optimized centrifugal blood pump with levitating impeller
    Mueller, JP
    Kuenzli, A
    Reuthebuch, O
    Dasse, K
    Kent, S
    Zuend, G
    Turina, MI
    Lachat, ML
    HEART SURGERY FORUM, 2004, 7 (05): : E477 - E480
  • [49] A Passive Magnetically and Hydrodynamically Suspended Rotary Blood Pump
    Stoiber, Martin
    Grasl, Christian
    Pirker, Stefan
    Raderer, Franz
    Schistek, Roland
    Huber, Leopold
    Gittler, Philipp
    Schima, Heinrich
    ARTIFICIAL ORGANS, 2009, 33 (03) : 250 - 257
  • [50] Hemolytic effect of surface roughness of an impeller in a centrifugal blood pump
    Takami, Y
    Nakazawa, T
    Makinouchi, K
    Tayama, E
    Glueck, J
    Benkowski, R
    Nose, Y