Effect of femoral neck modularity upon the prosthetic range of motion in total hip arthroplasty

被引:0
作者
Glen A. Turley
Damian R. Griffin
Mark A. Williams
机构
[1] The University of Warwick,WMG
[2] The University of Warwick,Warwick Medical School
来源
Medical & Biological Engineering & Computing | 2014年 / 52卷
关键词
Total hip arthroplasty; Femoral neck modularity; Impingement; Range of motion;
D O I
暂无
中图分类号
学科分类号
摘要
In total hip arthroplasty, aseptic loosening and dislocation are associated with not being able to achieve the correct prosthetic component orientation. Femoral neck modularity has been proposed as a solution to this problem by allowing the surgeon to alter either the neck-shaft or version angle of the prosthetic femoral component intra-operatively. A single replicate full factorial design was used to evaluate how effective a modular femoral neck cementless stem was in restoring a healthy prosthetic range of motion in comparison with a leading fixed-neck cementless stem with the standard modular parameters. It was found that, if altered to a large enough degree, femoral neck modularity can increase the amount of prosthetic motion as well as alter its position to where it is required physiologically. However, there is a functional limit to the amount that can be corrected and there is a risk with regard to the surgeon having to select the optimum modular neck before any benefit is realised.
引用
收藏
页码:685 / 694
页数:9
相关论文
共 191 条
  • [1] Baxmann M(2012)The influence of contact conditions and micromotions on the fretting behavior of modular titanium alloy taper connections Med Eng Phys 35 676-683
  • [2] Jauch SY(2009)CircStat: a MATLAB toolbox for circular statistics J Stat Softw 31 1-21
  • [3] Schilling C(2005)Range of motion and stability in total hip arthroplasty with 28-, 32-, 38-, and 44-mm femoral head sizes: an in vitro study J Arthroplasty 20 11-19
  • [4] Blömer W(2011)What works best, a cemented or cementless primary total hip arthroplasty? Minimum 17-year followup of a randomized controlled trial Clin Orthop Relat Res 469 209-217
  • [5] Grupp TM(1979)A screening design for factorial experiments with interactions Biometrika 66 317-320
  • [6] Morlock MM(2009)Combined anteversion technique for total hip arthroplasty Clin Orthop Relat Res 467 119-127
  • [7] Berens P(2010)Clinical results of a modular neck hip system: hitting the bulls-eye more accurately Am J Orthop 39 2-6
  • [8] Burroughs BR(2005)Obtaining a best fitting plane through 3D georeferenced data J Struct Geol 27 855-858
  • [9] Hallstrom B(2002)Factors predisposing to dislocation after primary total hip arthroplasty: a multivariate analysis J Arthroplasty 17 282-288
  • [10] Golladay GJ(2007)Influence of femoral head size on impingement, dislocation and stress distribution in total hip replacement Med Eng Phys 29 465-471