Validation of the use of foreign gas rebreathing method for non-invasive determination of cardiac output in heart disease patients.

被引:28
|
作者
Dong L. [1 ]
Wang J.A. [1 ]
Jiang C.Y. [1 ]
机构
[1] Department of Cardiology, Sir Run Run Shaw Hospital, School of Medicine, Zhejiang University, Hangzhou
来源
Journal of Zhejiang University SCIENCE B | 2005年 / 6卷 / 12期
关键词
Indirect Fick (foreign gas rebreathing); Swan-Ganz; Cardiac output; Left ventricle radiography; Echocardiography; R543.3;
D O I
10.1631/jzus.2005.B1157
中图分类号
学科分类号
摘要
OBJECTIVE: To compare a new device (Innocor) for non-invasive measurement of cardiac output (CO) by foreign gas rebreathing method with conventional techniques used in the measurements of cardiac function. METHODS: Cardiac outputs measured by Innocor (CO(RB)) were compared with CO obtained by echocardiography (CO(EC)), Swan-Ganz thermodilution (CO(TD)), and left ventricle radiography (CO(LVR)) in 34 patients subjected to cardiac catheterization. Values obtained from the four methods were analyzed by linear regression and paired values were compared by the method of Bland and Altman in SPSS. RESULTS: There was strong positive correlation (r=0.94) between Innocor cardiac output values and the corresponding values obtained by thermodilution and between CO(EC) and CO(LVR) values. Thermodilution appears to overestimate cardiac output when compared to the values obtained with Innocor by (0.66+/-0.22) L/min (P<0.0001). There was no correlation between data obtained by Innocor and the corresponding CO(EC) and CO(LVR) values. CONCLUSION: Innocor CO(RB) is an easy, safe and well established method for non-invasive measurement of cardiac output with good prospects for clinical application in heart disease patients.
引用
收藏
页码:1157 / 1162
页数:5
相关论文
共 50 条
  • [41] Non-invasive cardiac output measurement with electrical velocimetry in patients undergoing liver transplantation: comparison of an invasive method with pulmonary thermodilution
    De-Jie Wang
    I-Shan Lee
    An-Hsun Chou
    Chun-Yu Chen
    Pei-Chi Ting
    Yun-Hui Teng
    Jr-Rung Lin
    Hsin-I Tsai
    BMC Anesthesiology, 18
  • [42] Non-invasive measurement of cardiac output using an iterative, respiration-based method
    Klein, M.
    Minkovich, L.
    Machina, M.
    Selzner, M.
    Spetzler, V. N.
    Knaak, J. M.
    Roy, D.
    Duffin, J.
    Fisher, J. A.
    BRITISH JOURNAL OF ANAESTHESIA, 2015, 114 (03) : 406 - 413
  • [43] Non-invasive assessment of pulmonary blood flow using an inert gas rebreathing device in fibrotic lung disease
    Corte, Tamera J.
    Wells, Athol U.
    Gatzoulis, Michael A.
    Cramer, Derek
    Ward, Simon
    Macdonald, Peter S.
    Dimopoulos, Konstantinos
    Wort, Stephen J.
    THORAX, 2010, 65 (04) : 341 - 345
  • [44] Non-Invasive Cardiac Output Determination Using Magnetic Resonance Imaging and Thermodilution in Pulmonary Hypertension
    Crowe, Lindsey A.
    Genecand, Leon
    Hachulla, Anne-Lise
    Noble, Stephane
    Beghetti, Maurice
    Vallee, Jean-Paul
    Lador, Frederic
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (10)
  • [45] Quantification of the impaired cardiac output response to exercise in heart failure: Application of a non-invasive device
    Myers, Jonathan
    Gujja, Pradeep
    Neelagaru, Suresh
    Hsu, Leon
    Burkhoff, Daniel
    JOURNAL OF SPORTS SCIENCE AND MEDICINE, 2009, 8 (03) : 344 - 351
  • [46] Non-invasive cardiac output monitoring device “ICON” in trauma patients: a feasibility study
    Matthias Kuster
    Tobias Haltmeier
    Aristomenis Exadaktylos
    Beat Schnüriger
    European Journal of Trauma and Emergency Surgery, 2019, 45 : 1069 - 1076
  • [47] Strategic multimodal non-invasive assessment of cardiac performance in patients with heart failure
    Kim, Mi-Jeong
    Cho, Jung Sun
    Lee, Kyusup
    Kwon, Woojin
    Ohn, Chaeryeon
    Lee, Myunhee
    Kim, Dae-Won
    Kim, Tae-Seok
    Park, Mahn-Won
    ESC HEART FAILURE, 2023, 10 (04): : 2567 - 2576
  • [48] Non-invasive cardiac output monitoring device "ICON" in trauma patients: a feasibility study
    Kuster, Matthias
    Haltmeier, Tobias
    Exadaktylos, Aristomenis
    Schnueriger, Beat
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2019, 45 (06) : 1069 - 1076
  • [49] Instantaneous, easy, and non-invasive measurement of blood pressure, heart rate, and cardiac output: usefulness in physiotherapy
    Lamotte, M.
    REANIMATION, 2012, 21 (06): : 765 - 771
  • [50] Cardiac output measurements in congenital heart disease - Validation of a simple, portable Doppler method
    Gentles, TL
    Neutze, JM
    Caulder, AL
    Greene, ER
    JOURNAL OF ULTRASOUND IN MEDICINE, 2001, 20 (04) : 365 - 370