Clinical implications of coronary pressure measurement after stent implantation

被引:16
作者
Matsuo A. [1 ]
Fujita H. [1 ]
Tanigaki T. [1 ]
Shimonaga T. [1 ]
Ueoka A. [1 ]
Tsubakimoto Y. [1 ]
Sakatani T. [1 ]
Kimura S. [1 ]
Inoue K. [1 ]
Kitamura M. [1 ]
机构
[1] Department of Cardiology, Kyoto Second Red Cross Hospital, 355-5 Haruobi-cho, Kamanzadorimarutamachi, Kamigyo-ku, Kyoto
关键词
Fractional flow reserve; Stent optimization; Target lesion revascularization;
D O I
10.1007/s12928-012-0147-7
中图分类号
学科分类号
摘要
This study investigated the effect of fractional flow reserve (FFR) after stent implantation on clinical outcomes. Pressurewire measurements and follow-up data were obtained after stent implantation. Regarding the end point, target lesion revascularization (TLR) occurred in 11 patients (15. 9 %). Patients with TLR had higher frequencies of multiple stenting (54. 5 vs. 19. 0 %, p = 0. 01), lower post-interventional FFRs (0. 84 vs. 0. 88, p = 0. 01), and longer stent lengths (42. 20 vs. 27. 69 mm, p = 0. 01) than patients without TLR. The post-interventional FFR cutoff for TLR was 0. 79, although this value had a weak discriminatory ability. However, multivariate analysis did not show any significant independent predictors of TLR (odds ratio 6. 33; confidence interval 0. 75-53. 4, p = 0. 09). Post-interventional FFR values were not significantly associated with TLR when a sub-analysis was performed in patients who underwent only drug-eluting stent (DES) implantation. It was difficult to achieve post-interventional FFRs of 0. 9 or greater. DES implantation eliminated the effect of post-interventional FFR on TLR. Post-interventional FFR was not able to predict TLR in the present study. © 2012 Japanese Association of Cardiovascular Intervention and Therapeutics.
引用
收藏
页码:170 / 177
页数:7
相关论文
共 25 条
  • [1] Pijls, N.H.J., Bruyne, B.D., Peels, K., van der Voort, P.H., Bonnier, H.J.R., Bartunek, J., Measurement of fractional flow reserve to assess the functional severity of coronary-artery stenosis (1996) N Engl J Med, 334, pp. 1703-1708
  • [2] Pijls, N.H.J., van Gelder, B., van der Voort, P., Peels, K., Frank, A.L.E., Bracke, F.A.L.E., Fractional flow reserve a useful Index to evaluate the influence of an epicardial coronary stenosis on myocardial blood flow (1995) Circulation, 92, pp. 3183-3193
  • [3] William, K.H., Fractional flow reserve and complex coronary pathologic condition (2004) Eur Heart J, 25, pp. 723-727
  • [4] Bech, G.J.W., Pijls, N.H.J., De Bruyne, B., Peels, K.H., Michels, H.R., Bonnier, H.J.R.M., Usefulness of fractional flow reserve to predict clinical outcome after balloon angioplasty (1999) Circulation, 99, pp. 883-888
  • [5] Hanekamp, C.E.E., Koolen, J.J., Pijls, N.H.J., Michels, H.R., Bonnier, H.J.R.M., Comparison of quantitative coronary angiography, intravascular ultrasound, and coronary pressure measurement to assess optimum stent deployment (1999) Circulation, 99, pp. 1015-1021
  • [6] Fearon, W.F., Luna, J., Samady, H., Powers, E.R., Feldman, T., Dib, N., Fractional flow reserve compared with intravascular ultrasound guidance for optimizing stent deployment (2001) Circulation, 104, pp. 1917-1922
  • [7] Pijls, N.H.J., Klauss, V., Siebert, U., Powers, E., Takazawa, K., Fearon, W., Coronary pressure measurement after stenting predicts adverse events at follow up: a multicenter registry (2002) Circulation, 105, pp. 2950-2954
  • [8] Nam, C.W., Hur, S.H., Cho, Y.K., Park, H.S., Yoon, H.J., Kim, H., Relation of fractional flow reserve after drug-eluting stent implantation to one-year outcomes (2011) Am J Cardiol, 107, pp. 1763-1767
  • [9] Wilson, R.F., White, C.W., Intracoronary papaverine: an ideal coronary vasodilator for studies of the coronary circulation in conscious humans (1986) Circulation, 73, pp. 444-451
  • [10] Gould, K.L., Nakagawa, Y., Nakagawa, K., Sdringola, S., Hess, M.J., Haynie, M., Frequency and clinical implications of fluid dynamically significant diffuse coronary artery disease manifest as graded, longitudinal, base-to-apex myocardial perfusion abnormality by noninvasive positron emission tomography (2000) Circulation, 101, pp. 1931-1939