Poly (naphthol green B) modified carbon paste electrode for the analysis of paracetamol and norepinephrine

被引:0
作者
Chethan M Kuskur
B.E. Kumara Swamy
H. Jayadevappa
机构
[1] Kuvempu University,Department of P.G. Studies and Research in Industrial Chemistry
[2] Sahyadri Science College,Departments of Chemistry
来源
Ionics | 2019年 / 25卷
关键词
Paracetamol; Norepinephrine; Naphthol green B; Electropolymerization; Carbon paste electrode; Voltammetry;
D O I
暂无
中图分类号
学科分类号
摘要
A stable modified carbon paste electrode based on the poly (naphthol green B) film was prepared by electrochemical polymerization method using cyclic voltammetry. The poly (naphthol green B) modified carbon paste electrode showed excellent high electrocatalytic activity towards the paracetamol (PA) and norepinephrine (NE) oxidation, with significant enhancement of the peak currents in neutral pH (7.0) phosphate buffer solution (0.2 M PBS), at the sweep rate 100 mV/s. The sweep rate and pH (6.2 to 7.8) effects on the voltammograms of PA and NE were studied. The lower limit of detection of PA and NE was found to be 1.6 and 2.0 μM, respectively. The simultaneous determination of PA and NE was investigated by cyclic voltammetry (CV). The peak to peak separation of PA and NE was about 173 mV. The interference study was carried out by differential pulse voltammetry (DPV). The modified electrode showed good sensor for the determination of PA and NE. This method was used for the determination of real sample analysis of PA in commercial tablet and NE in injection sample.
引用
收藏
页码:1845 / 1855
页数:10
相关论文
共 201 条
[1]  
Khaskheli AR(2013)Differential pulse voltammetric determination of paracetamol in tablet and urine samples at a micro-crystalline natural graphite–polystyrene composite film modified Electrochim Acta 101 238-242
[2]  
Fischer J(1970)The determination of paracetarnol and aspirin in mixtures by nonaqueous potentiometric titrimetry or by ultraviolet spectrophotometry Anal Chim Acta 49 342-345
[3]  
Barek J(2004)A sensor for acetaminophen in a blood medium using a Cu (II)-conducting polymer complex modified electrode Anal Chim Acta 512 191-197
[4]  
Vyskocil V(2009)Effects of capacitance and resistance of MWNT-film coated electrodes on voltammetric detection of acetaminophen J Appl Electrochem 39 1145-300
[5]  
Sirajuddin MI(2018)Facile one pot synthesis of bimetallic Pd-Ag/reduced graphene oxide nanocomposite as an electrochemical sensor for sensitive detection of antihypotensive drug Colloids Surf A 546 293-752
[6]  
Bhanger AG(2009)Simultaneous voltammetric determination of paracetamol and caffeine in pharmaceutical formulations using a boron-doped diamond electrode Talanta 78 748-759
[7]  
Fogg PJ(2010)A graphene-based electrochemical sensor for sensitive detection of paracetamol Talanta 81 754-136
[8]  
Sausins JR(2007)Electrochemical determination of acetaminophen using a glassy carbon electrode coated with a single-wall carbon nanotube-dicetyl phosphate film Microchim Acta 158 131-2553
[9]  
Smithson M(2006)A comparative study of Pb2+ selective sensors based on derivatized tetrapyrazole and calix[4]arene receptors Electrochim Acta 51 2547-3146
[10]  
Boopathi MS(2018)An ultra-sensitive electrochemical sensor for the detection of acetaminophen in the presence of etilefrine using bimetallic Pd–Ag/reduced graphene oxide nanocomposites New J Chem 42 3137-616