Accurate measurement of the bond stress between rebar and concrete in reinforced concrete using FBG sensing technology

被引:2
作者
Ahmed, Murshalin [1 ]
Matsumoto, Yukihiro [2 ]
Yoon, Rokhyun [1 ]
Takahashi, Susumu [3 ]
Sanada, Yasushi [1 ]
机构
[1] Osaka Univ, Dept Architectural Engn, Osaka, Japan
[2] Toyohashi Univ Technol, Dept Architecture & Civil Engn, Toyohashi, Aichi, Japan
[3] Daido Univ, Dept Architecture, Nagoya, Aichi, Japan
基金
日本学术振兴会;
关键词
FIBER; SENSORS;
D O I
10.1038/s41598-024-52555-w
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Recent earthquakes in several developing countries have shown that reinforced concrete (RC) buildings with improper structural detailing experience severe damage under seismic motions. Using low-quality construction materials such as brick aggregates, resulting in low-strength concrete, significantly impacts the bond between rebar and concrete. Accurate evaluation of the bond performance of such low-strength concrete is one of the key issues for seismic safety assessment of RC buildings, especially in Bangladesh; thus, the bond performance is usually evaluated through laboratory tests. However, conventional measurements of bond stress based on rebar strains measured by electrical resistance strain gauges are likely to negatively impact the bond behavior/performance because of the reduced total contact area between rebar and concrete as well as the changing rebar surface boundary conditions. Under the above social and academic backgrounds, in this study, a new measurement technique that applies fiber Bragg grating (FBG) sensors embedded in optical fiber to rebar strain measurements is developed, and its effectiveness is investigated to realize more accurate measurements of the bond stress between rebar and concrete. Two 70% scaled RC beam-column joint specimens in which the beam rebar was anchored in a straight manner were constructed with identical detailing, except for the beam rebar strain measuring methods. The specimens were then subjected to cyclic lateral loading until failure. By comparing the experimental data acquired by the above two different devices (the FBG sensors and conventional strain gauges), it was found that the experimental bond strength on the beam rebar based on the strain data measured by the FBG sensors was much higher than that from the data measured using conventional strain gauges. Which negatively impacted the test data on the beam-column joint's capacity in the specimen applied the conventional measuring method, indicating the necessity of the presented method not only for accurate evaluation of the bond stress between rebar and concrete but also for seismic safety assessments of RC buildings.
引用
收藏
页数:11
相关论文
共 26 条
  • [1] [Anonymous], 2020, JIS G 3112:2020
  • [2] Architectural Institute of Japan, 2016, Reconnaissance Report on the 2015, Nepal Gorkha Earthquake 1-381
  • [3] Architectural Institute of Japan (AIJ), 1997, Design Guidelines for Earthquake Resistant Reinforced Concrete Buildings Based on Inelastic Displacement Concept (Draft)
  • [4] Mechanical properties of brick aggregate concrete
    Cachim, Paulo B.
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2009, 23 (03) : 1292 - 1297
  • [5] Full-scale test of a concrete box girder using FBG sensing system
    Chung, Wonseok
    Kang, Donghoon
    [J]. ENGINEERING STRUCTURES, 2008, 30 (03) : 643 - 652
  • [6] Earthquake Engineering Research Institute (EERI), 2009, EERI Special Earthquake Report 1-12
  • [7] Temporary cable force monitoring techniques during bridge construction-phase: the Tajo River Viaduct experience
    Gaute-Alonso, Alvaro
    Garcia-Sanchez, David
    Alonso-Cobo, Carlos
    Calderon-Uriszar-Aldaca, Inigo
    [J]. SCIENTIFIC REPORTS, 2022, 12 (01)
  • [8] Fiber Bragg grating technology fundamentals and overview
    Hill, KO
    Meltz, G
    [J]. JOURNAL OF LIGHTWAVE TECHNOLOGY, 1997, 15 (08) : 1263 - 1276
  • [9] Housing and Building Research Institute, 2015, Bangladesh National Building Code (BNBC) 2015 Final Draft
  • [10] Housing and Building Research Institute (HBRI), 2022, Technical Guidelines for Seismic Evaluation of Existing Reinforced Concrete Buildings in Bangladesh for Extended Application of PWD Seismic Evaluation Manual