Clinical outcomes of non-Descemet stripping automated endothelial keratoplasty

被引:15
|
作者
Sunita Chaurasia
Muralidhar Ramappa
Virender S. Sangwan
机构
[1] LV Prasad Eye Institute,Cornea and Anterior Segment Services
关键词
Descemet membrane; Endothelial keratoplasty; Descemet stripping endothelial keratoplasty;
D O I
10.1007/s10792-012-9615-4
中图分类号
学科分类号
摘要
To describe the results of non-Descemet stripping automated endothelial keratoplasty (non-DSAEK). Retrospective, interventional, consecutive clinical case series. Twenty-three patients underwent non-DSAEK from January 2010 to February 2011. The various indications were pseudophakic corneal edema, aphakic corneal edema, failed graft, iridocorneal endothelial syndrome and congenital glaucoma. Corneal edema cleared in all patients within 1–4 weeks. Mean follow-up duration was 7.6 months. Post-operative best corrected visual acuity ranged from 20/400 to 20/40. Fourteen patients had co-morbid factors affecting the vision. No patient had interface haze. Immediate post-operative complications were partial graft detachment (1 patient) and secondary angle closure (1 patient). Corneal clarity was restored following secondary interventions. One late post-operative complication was graft rejection at 6 months, leading to graft failure. Non-DSAEK is a safe and viable option in cases of corneal decompensation when the Descemet membrane is non-pathological.
引用
收藏
页码:571 / 575
页数:4
相关论文
共 50 条
  • [31] Spontaneous Corneal Clearance in the Presence of a Partially Detached Graft after Non-Descemet Stripping Automated Endothelial Keratoplasty
    Droutsas, Konstantinos
    Lazaridis, Apostolos
    Koutsandrea, Chrysanthi
    Chatzistefanou, Klio I.
    Moschos, Marilita M.
    Sekundo, Walter
    CASE REPORTS IN OPHTHALMOLOGY, 2016, 7 (02): : 320 - 326
  • [32] Descemet Membrane Endothelial Keratoplasty Versus Descemet Stripping Automated Endothelial Keratoplasty and Penetrating Keratoplasty
    Woo, Jyh-Haur
    Ang, Marcus
    Htoon, Hla Myint
    Tan, Donald
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2019, 207 : 288 - 303
  • [33] Complications and Clinical Outcomes of Descemet Stripping Automated Endothelial Keratoplasty With Intraocular Lens Exchange
    Shah, Anand K.
    Terry, Mark A.
    Shamie, Neda
    Chen, Edwin S.
    Phillips, Paul M.
    Hoar, Karen L.
    Friend, Daniel J.
    Davis-Boozer, David
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2010, 149 (03) : 390 - 397
  • [34] Complications and Clinical Outcomes of Descemet Stripping Automated Endothelial Keratoplasty With Intraocular Lens Exchange
    Chiang, Chun-Chi
    Tsai, Yi-Yu
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2010, 150 (01) : 130 - 131
  • [35] Clinical Outcomes of Replacing a Failed Descemet's Stripping Automated Endothelial Keratoplasty Graft
    Bauer, Alex
    Potts, Luke
    Chen, Shin-Yi
    Tran, Khoa D.
    Straiko, Michael D.
    Terry, Mark A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [36] Outcomes of Descemet membrane endothelial keratoplasty, Descemet stripping automated endothelial keratoplasty and penetrating keratoplasty from a single centre study
    S. Heinzelmann
    D. Böhringer
    P. Eberwein
    T. Reinhard
    P. Maier
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2016, 254 : 515 - 522
  • [37] Clinical Outcomes of Penetrating Keratoplasty and Descemet Stripping Automated Endothelial Keratoplasty in Asian Population with American Corneas
    Hsiao, Fang-Chi
    Chen, Po-Yuan
    Meir, Yaa-Jyuhn James
    Tan, Hsin-Yuan
    Hsiao, Ching-Hsi
    Lin, Hsin-Chiung
    Ma, David Hui-Kang
    Yeh, Lung-Kun
    Wu, Wei-Chi
    Chen, Hung-Chi
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2019, 16 (22)
  • [38] Microthin Descemet Stripping Automated Endothelial Keratoplasty Versus Descemet Membrane Endothelial Keratoplasty: A Randomized Clinical Trial
    Matsou, Artemis
    Pujari, Rathin
    Sarwar, Hammad
    Rana, Mrinal
    Myerscough, James
    Thomson, Susan M.
    Nandakumar, Girinath
    Zhang, Jufen
    Rajan, Madhavan S.
    CORNEA, 2021, 40 (09) : 1117 - 1125
  • [39] Is Nanothin Descemet Stripping Automated Endothelial Keratoplasty Comparable to Descemet Membrane Endothelial Keratoplasty?
    Sahay, Pranita
    Singhal, Deepali
    Maharana, Prafulla K.
    Titiyal, Jeewan S.
    CORNEA, 2018, 37 (12) : E56 - E56
  • [40] Outcomes of Descemet membrane endothelial keratoplasty, Descemet stripping automated endothelial keratoplasty and penetrating keratoplasty from a single centre study
    Heinzelmann, S.
    Boehringer, D.
    Eberwein, P.
    Reinhard, T.
    Maier, P.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2016, 254 (03) : 515 - 522