Gamma spectrometric determination of the isotopic decomposition of plutonium in containers using MGA and FRAM software

被引:0
|
作者
A. V. Bushuev
T. B. Aleeva
A. F. Kozhin
E. V. Petrova
V. N. Zubarev
A. M. Pavlov
A. F. Myrzin
A. A. Syrosev
机构
[1] National Nuclear Research University – Moscow Engineering-Physics Institute (NIYaU MIFI),
[2] Mayak Industrial Association,undefined
来源
Atomic Energy | 2012年 / 113卷
关键词
Isotopic Composition; Plutonium; Plutonium Isotope; Average Relative Deviation; Plutonium Dioxide;
D O I
暂无
中图分类号
学科分类号
摘要
Plutonium dioxide is stored in special containers, holding about 3 kg plutonium each, in a dump at the RT-1 plant of the Industrial Association Mayak. The certificates on the containers with plutonium produced in 1990–2000 do not contain any data on the isotopic composition. Without removing the plutonium from a container, the isotopic composition can be determined only by γ-spectrometry. This paper compares the MGA and FRAM computer codes used to determine the isotopic composition of the plutonium when performing measurements on samples with a large mass.
引用
收藏
页码:117 / 124
页数:7
相关论文
共 50 条