Gamma spectrometric determination of the isotopic decomposition of plutonium in containers using MGA and FRAM software

被引:0
|
作者
A. V. Bushuev
T. B. Aleeva
A. F. Kozhin
E. V. Petrova
V. N. Zubarev
A. M. Pavlov
A. F. Myrzin
A. A. Syrosev
机构
[1] National Nuclear Research University – Moscow Engineering-Physics Institute (NIYaU MIFI),
[2] Mayak Industrial Association,undefined
来源
Atomic Energy | 2012年 / 113卷
关键词
Isotopic Composition; Plutonium; Plutonium Isotope; Average Relative Deviation; Plutonium Dioxide;
D O I
暂无
中图分类号
学科分类号
摘要
Plutonium dioxide is stored in special containers, holding about 3 kg plutonium each, in a dump at the RT-1 plant of the Industrial Association Mayak. The certificates on the containers with plutonium produced in 1990–2000 do not contain any data on the isotopic composition. Without removing the plutonium from a container, the isotopic composition can be determined only by γ-spectrometry. This paper compares the MGA and FRAM computer codes used to determine the isotopic composition of the plutonium when performing measurements on samples with a large mass.
引用
收藏
页码:117 / 124
页数:7
相关论文
共 50 条
  • [21] DETERMINATION OF URANIUM ENRICHMENT BY USING GAMMA-SPECTROMETRIC METHODS
    Kutniy, D. V.
    Telegin, Yu. N.
    Odeychuk, N. P.
    Mikhaylov, V. A.
    Tovkanets, V. E.
    PROBLEMS OF ATOMIC SCIENCE AND TECHNOLOGY, 2009, (04): : 256 - 262
  • [22] Determination of radioactive waste activity in containers using a xenon gamma spectrometer
    P'ya, S. N.
    Vlasik, K. F.
    Grachev, V. M.
    Dmitrenko, V. V.
    Novikov, A. S.
    Petrenko, D. V.
    Shustov, A. E.
    Uteshev, Z. M.
    Ulin, S. E.
    Chernysheva, I. V.
    BULLETIN OF THE LEBEDEV PHYSICS INSTITUTE, 2015, 42 (08) : 249 - 253
  • [23] Determination of radioactive waste activity in containers using a xenon gamma spectrometer
    S. N. P’ya
    K. F. Vlasik
    V. M. Grachev
    V. V. Dmitrenko
    A. S. Novikov
    D. V. Petrenko
    A. E. Shustov
    Z. M. Uteshev
    S. E. Ulin
    I. V. Chernysheva
    Bulletin of the Lebedev Physics Institute, 2015, 42 : 249 - 253
  • [24] QUANTITATIVE-DETERMINATION OF RADIONUCLIDES ON EXTENDED SOURCES USING GAMMA-SPECTROMETRIC METHODS
    GEHRCKE, K
    KERNENERGIE, 1989, 32 (06): : 252 - 255
  • [25] DETERMINATION OF AMERICIUM-241 IN PURE PLUTONIUM USING EXTRACTION WITH TRIOCTYLPHOSPHINE OXIDE AND GAMMA COUNTING
    BUBERNAK, J
    LEW, MS
    MATLACK, GM
    ANALYTICAL CHEMISTRY, 1967, 39 (10) : 1167 - &
  • [26] INTRINSIC SELF-CALIBRATION OF NONDESTRUCTIVE GAMMA SPECTROMETRIC MEASUREMENTS DETERMINATION OF U, PU AND AM-241 ISOTOPIC RATIOS
    DRAGNEV, TN
    JOURNAL OF RADIOANALYTICAL CHEMISTRY, 1977, 36 (02): : 491 - 508
  • [27] Determination of isotopic ratios of uranium samples using passive gamma spectroscopy with multiple detectors
    S. Horne
    S. Landsberger
    B. Dickson
    Journal of Radioanalytical and Nuclear Chemistry, 2014, 299 : 1171 - 1175
  • [28] Determination of isotopic ratios of uranium samples using passive gamma spectroscopy with multiple detectors
    Horne, S.
    Dickson, B.
    Landsberger, S.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2013, 245
  • [29] Determination of isotopic ratios of uranium samples using passive gamma spectroscopy with multiple detectors
    Horne, S.
    Landsberger, S.
    Dickson, B.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2014, 299 (03) : 1171 - 1175
  • [30] ACCURATE DETERMINATION OF PLUTONIUM K-ABSORPTION EDGE ENERGY USING GAMMA-RAY ATTENUATION
    CANADA, TR
    BEARSE, RC
    TAPE, JW
    NUCLEAR INSTRUMENTS & METHODS, 1977, 142 (03): : 609 - 611