A thermal-driven method based on Brillouin fiber-optic sensors for the quantitative identification of subsurface cavities in concrete-filled steel tube structures

被引:0
|
作者
Shilin Gong
Xin Feng
Guanhua Zhang
机构
[1] Dalian University of Technology,State Key Laboratory of Coastal and Offshore Engineering
[2] Ministry of Transport of China,Research and Development Center on Road and Bridge Diagnosis and Maintenance Technology
关键词
Concrete-filled steel tube; Subsurface cavity; Thermal-driven; Brillouin fiber-optic sensor; Temperature anomaly; Equivalent heat absorption coefficient;
D O I
暂无
中图分类号
学科分类号
摘要
In the composite structure of a concrete-filled steel tube (CFST), because the concrete is concealed inside the steel tube, subsurface cavities can occur and are difficult to identify. In this study, a thermal-driven method based on Brillouin fiber-optic sensors (BFOSs) was proposed to quantitatively identify subsurface cavities in CFSTs. By performing a thermodynamic analysis of subsurface cavities in CFSTs, a thermal model related to the relationship between the subsurface cavity size and the temperature rise at the top surface of the CFST was established for the first time. Then, a sensing scheme based on the BFOS was proposed, and its feasibility was evaluated through an experimental program. The experimental program involved the use of an active heating layer for inputting heat flow into the CFST structure and BFOSs for the distributed measurement of temperature to identify subsurface cavities in CFSTs. The experimental results indicated that the BFOSs can achieve real-time distributed measurements of the surface temperature of the CFSTs. According to the temperature anomalies in the temperature rise curves of the CFSTs, the subsurface cavities can be accurately located in the longitudinal direction of the CFST, and its length can be quantified. There is an obvious linear relationship between the temperature rise and the square root of the heating time, from which the equivalent heat absorption coefficient (EHAC) can be determined. Furthermore, according to the relationship between the subsurface cavity height and the EHAC in the thermodynamic theoretical analysis, the subsurface cavity height can be obtained quantitatively.
引用
收藏
页码:521 / 536
页数:15
相关论文
共 4 条
  • [1] A thermal-driven method based on Brillouin fiber-optic sensors for the quantitative identification of subsurface cavities in concrete-filled steel tube structures
    Gong, Shilin
    Feng, Xin
    Zhang, Guanhua
    JOURNAL OF CIVIL STRUCTURAL HEALTH MONITORING, 2021, 11 (02) : 521 - 536
  • [2] Brillouin Corrosion Expansion Sensors for Steel Reinforced Concrete Structures Using a Fiber Optic Coil Winding Method
    Zhao, Xuefeng
    Gong, Peng
    Qiao, Guofu
    Lu, Jie
    Lv, Xingjun
    Ou, Jinping
    SENSORS, 2011, 11 (11) : 10798 - 10819
  • [3] Thermal Stress of Concrete-filled Steel Tube Arch During Hardening Process Based on Equivalent Age Method
    Sun J.
    Xie J.
    Tongji Daxue Xuebao/Journal of Tongji University, 2019, 47 (06): : 755 - 763
  • [4] Analysis on displacement-based seismic design method of recycled aggregate concrete-filled square steel tube frame structures
    Zhang, Xianggang
    Liu, Xuyan
    Zhang, Songpeng
    Wang, Junbo
    Fu, Lei
    Yang, Junna
    Huang, Yajun