Magnetic resonance imaging for jawbone assessment: a systematic review

被引:4
作者
Parize, Hian [1 ,2 ]
Sadilina, Sofya [1 ,3 ]
Caldas, Ricardo Armini [4 ]
Cordeiro, Joao Victor Cunha [4 ]
Kleinheinz, Johannes [1 ]
Lagana, Dalva Cruz [2 ]
Sesma, Newton [2 ]
Bohner, Lauren [1 ,4 ]
机构
[1] Univ Hosp Munster, Dept Cranio Maxillofacial Surg, Munster, Germany
[2] Univ Sao Paulo, Dept Prosthodont, Sao Paulo, Brazil
[3] Univ Zurich, Ctr Dent Med, Clin Reconstruct Dent, Zurich, Switzerland
[4] Univ Fed Santa Catarina, Dept Dent, 1240 Trindade, BR-88040535 Florianopolis, SC, Brazil
关键词
Surgery oral; Magnetic resonance imaging; Bone Assessment; Systematic review; COMPUTED-TOMOGRAPHY; BONE; ACCURACY; QUALITY;
D O I
10.1186/s13005-024-00424-2
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose To evaluate the accuracy of magnetic resonance imaging (MRI) for jawbone assessment compared to reference-standard measurements in the literature.Materials and methods An electronic database search was conducted in PubMed, EMBASE, Scopus, Web of Science, and the Cochrane Library in June 2022, and updated in August 2023. Studies evaluating the accuracy of MRI for jawbone assessment compared with reference-standard measurements (histology, physical measurements, or computed tomography) were included. The outcome measures included bone histomorphometry and linear measurements. The risk of bias was assessed by the Quality Assessment Tool for Diagnostic Accuracy Studies (QUADAS-2). The review was registered in the PROSPERO database (CRD42022342697).Results From 63 studies selected for full-text analysis, nine manuscripts were considered eligible for this review. The studies included assessments of 54 participants, 35 cadavers, and one phantom. A linear measurement error ranging from 0.03 to 3.11 mm was shown. The accuracy of bone histomorphometry varies among studies. Limitations of the evidence included heterogeneity of MRI protocols and the methodology of the included studies.Conclusion Few studies have suggested the feasibility of MRI for jawbone assessment, as MRI provides comparable results to those of standard reference tests. However, further advancements and optimizations are needed to increase the applicability, validate the efficacy, and establish clinical utility of these methods.
引用
收藏
页数:10
相关论文
共 42 条
[1]   Accuracy of magnetic resonance imaging compared with computed tomography for implant planning [J].
Aguiar, Marcelo F. ;
Marques, Alexandre P. ;
Carvalho, Antonio Carlos P. ;
Cavalcanti, Marcelo G. P. .
CLINICAL ORAL IMPLANTS RESEARCH, 2008, 19 (04) :362-365
[2]   Buccal bone thickness assessment for immediate anterior dental implant planning: A pilot study comparing cone-beam computed tomography and 3D double-echo steady-state MRI [J].
Al-Haj Husain, Adib ;
Stadlinger, Bernd ;
Ozcan, Mutlu ;
Schonegg, Daphne ;
Winklhofer, Sebastian ;
Al-Haj Husain, Nadin ;
Piccirelli, Marco ;
Valdec, Silvio .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2023, 25 (01) :35-45
[3]   Magnetic resonance imaging for preoperative diagnosis in third molar surgery: a systematic review [J].
Al-Haj Husain, Adib ;
Stadlinger, Bernd ;
Winklhofer, Sebastian ;
Piccirelli, Marco ;
Valdec, Silvio .
ORAL RADIOLOGY, 2023, 39 (01) :1-17
[4]   Evaluation of four different optimized magnetic-resonance-imaging sequences for visualization of dental and maxillo-mandibular structures at 3 T [J].
Assaf, Alexandre T. ;
Zrnc, Tomislav A. ;
Remus, Chressen C. ;
Schoenfeld, Michael ;
Habermann, Christian R. ;
Riecke, Bjoern ;
Friedrich, Reinhard E. ;
Fiehler, Jens ;
Heiland, Max ;
Sedlacik, Jan .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2014, 42 (07) :1356-1363
[5]   Artifacts in magnetic resonance imaging caused by dental materials: a systematic review [J].
Bohner, Lauren ;
Hanisch, Marcel ;
Sesma, Newton ;
Blanck-Lubarsch, Moritz ;
Kleinheinz, Johannes .
DENTOMAXILLOFACIAL RADIOLOGY, 2022, 51 (06)
[6]   Trabecular Bone Assessment Using Magnetic-Resonance Imaging: A Pilot Study [J].
Bohner, Lauren ;
Tortamano, Pedro ;
Meier, Norbert ;
Gremse, Felix ;
Kleinheinz, Johannes ;
Hanisch, Marcel .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (24) :1-7
[7]   An international registry of systematic-review protocols [J].
Booth, Alison ;
Clarke, Mike ;
Ghersi, Davina ;
Moher, David ;
Petticrew, Mark ;
Stewart, Lesley .
LANCET, 2011, 377 (9760) :108-109
[8]   Ultrashort echo time (UTE) MRI for the assessment of caries lesions [J].
Bracher, A-K ;
Hofmann, C. ;
Bornstedt, A. ;
Hell, E. ;
Janke, F. ;
Ulrici, J. ;
Haller, B. ;
Geibel, M-A ;
Rasche, V. .
DENTOMAXILLOFACIAL RADIOLOGY, 2013, 42 (06)
[9]   Pediatric Bone Marrow MR Imaging [J].
Burdiles, Alvaro ;
Babyn, Paul S. .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2009, 47 (06) :881-+
[10]   Standardized Nomenclature, Symbols, and Units for Bone Histomorphometry: A 2012 Update of the Report of the ASBMR Histomorphometry Nomenclature Committee [J].
Dempster, David W. ;
Compston, Juliet E. ;
Drezner, Marc K. ;
Glorieux, Francis H. ;
Kanis, John A. ;
Malluche, Hartmut ;
Meunier, Pierre J. ;
Ott, Susan M. ;
Recker, Robert R. ;
Parfitt, A. Michael .
JOURNAL OF BONE AND MINERAL RESEARCH, 2013, 28 (01) :1-16