Comparison of two devices for respiratory impedance measurement using a forced oscillation technique: basic study using phantom models

被引:0
|
作者
Kazuya Tanimura
Toyohiro Hirai
Susumu Sato
Koichi Hasegawa
Shigeo Muro
Hajime Kurosawa
Michiaki Mishima
机构
[1] Kyoto University,Department of Respiratory Medicine, Graduate School of Medicine
[2] Tohoku University School of Medicine,Center for Environmental Conservation and Research Safety, Tohoku University Department of Occupational Health
来源
关键词
Forced oscillation; Impedance; Resistance; Reactance; Frequency dependence;
D O I
暂无
中图分类号
学科分类号
摘要
Since commercial forced oscillation technique (FOT) devices became available, they have been widely used for physiological assessments, mainly of obstructive lung diseases. However, it is not known whether the impedance values measured with different devices are identical. In this study, two FOT devices—the impulse oscillometry system (IOS) and the MostGraph (MG)—were compared using phantom models. The resistance values varied up to 10 % from estimated values in both devices. Additionally, there was a difference in frequency dependence for the resistance between the devices. The reactance values measured with MG were higher than those measured with IOS. The effects of ventilation on the measured impedance values were higher for IOS than for MG, especially at lower frequencies. We concluded that the devices do not always generate identical impedance values. Thus, differences between the devices should be taken into consideration when evaluating clinical data.
引用
收藏
页码:377 / 382
页数:5
相关论文
共 50 条
  • [1] Comparison of two devices for respiratory impedance measurement using a forced oscillation technique: basic study using phantom models
    Tanimura, Kazuya
    Hirai, Toyohiro
    Sato, Susumu
    Hasegawa, Koichi
    Muro, Shigeo
    Kurosawa, Hajime
    Mishima, Michiaki
    JOURNAL OF PHYSIOLOGICAL SCIENCES, 2014, 64 (05): : 377 - 382
  • [2] Comparison Of Three Devices For Respiratory Impedance Measurement Using Forced Oscillation Technique: Basic Study Using Phantom Models
    Sato, S.
    Hirai, T.
    Tanimura, K.
    Hasegawa, K.
    Muro, S.
    Mishima, M.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2015, 191
  • [3] An analogue instrument for the measurement of respiratory impedance using the forced oscillation technique
    Birch, M
    MacLeod, D
    Levine, M
    PHYSIOLOGICAL MEASUREMENT, 2001, 22 (02) : 323 - 339
  • [4] The Meaning Of The Impedance Of Respiratory System Measured By Forced Oscillation Technique - Fundamental Analysis Using The Phantom Model -
    Ogasa, T.
    Osanai, S.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2016, 193
  • [5] Perioperative evaluation of respiratory impedance using the forced oscillation technique: a prospective observational study
    Shoko Nakano
    Junko Nakahira
    Toshiyuki Sawai
    Yosuke Kuzukawa
    Junichi Ishio
    Toshiaki Minami
    BMC Anesthesiology, 16
  • [6] Perioperative evaluation of respiratory impedance using the forced oscillation technique: a prospective observational study
    Nakano, Shoko
    Nakahira, Junko
    Sawai, Toshiyuki
    Kuzukawa, Yosuke
    Ishio, Junichi
    Minami, Toshiaki
    BMC ANESTHESIOLOGY, 2016, 16
  • [7] MEASUREMENT OF TOTAL RESPIRATORY IMPEDANCE IN CALVES BY THE FORCED OSCILLATION TECHNIQUE
    GUSTIN, P
    DHEM, AR
    LOMBA, F
    LEKEUX, P
    VANDEWOESTIJNE, KP
    LANDSER, FJ
    JOURNAL OF APPLIED PHYSIOLOGY, 1988, 64 (05) : 1786 - 1791
  • [8] MEASUREMENT OF TOTAL RESPIRATORY IMPEDANCE IN DOGS BY THE FORCED OSCILLATION TECHNIQUE
    CLERCX, C
    GUSTIN, P
    LANDSER, FJ
    VANDEWOESTIJNE, KP
    VETERINARY RESEARCH COMMUNICATIONS, 1993, 17 (03) : 227 - 239
  • [9] MEASUREMENT OF TOTAL RESPIRATORY IMPEDANCE IN INFANTS BY THE FORCED OSCILLATION TECHNIQUE
    DESAGER, KN
    BUHR, W
    WILLEMEN, M
    VANBEVER, HP
    DEBACKER, W
    VERMEIRE, PA
    LANDSER, FJ
    JOURNAL OF APPLIED PHYSIOLOGY, 1991, 71 (02) : 770 - 776
  • [10] THE BASIC INTERPRETATION OF THE IMPEDANCE OF RESPIRATORY SYSTEM MEASURED BY FORCED OSCILLATION TECHNIQUE
    Ogasa, Toshiyuki
    Osanai, Shinobu
    RESPIROLOGY, 2017, 22 : 151 - 151