Evaluation of spatial-encoding-related geometric distortion in magnetic resonance imaging

被引:0
作者
Cheol Pyo Hong
Dong Hoon Lee
Man Woo Lee
Youngkeun Woo
机构
[1] Yonsei University,Department of Radiological Science and Institute of Health Science
[2] Samsung Electronics Co.,Research and Development, Health & Medical Equipment
[3] LTD,Department of Physical Therapy, College of Alternative Medicine
[4] Jeonju University,undefined
来源
Journal of the Korean Physical Society | 2012年 / 61卷
关键词
Spatial Encoding; Geometric distortion; MRI;
D O I
暂无
中图分类号
学科分类号
摘要
This study demonstrated the characteristics of spatial encoding-related geometric distortion in magnetic resonance imaging (MRI) by using a phantom with known physical dimensions to detect geometric distortion in MR scans. The amount of distortion was calculated as the difference between the physical coordinates of control points in the phantom and those of the corresponding points in the distorted MR image of the phantom. The phase and the frequency encoding directions were swapped to acquire a phantom image for movement of a patient table 120 mm to the right and left, allowing comprehensive distortion mapping over the isocentric plane and the entire field of view (FOV) along the spatial encoding. The geometric distortion of phase encoding directions over the entire FOV was small compared to the distortion of frequency encoding directions. The maximum absolute deviations were 28.00 mm and 20.00 mm along the frequency and the phase encoding directions over the entire FOV, respectively. The mean absolute deviations along the frequency and the phase encoding directions were 2.85 mm and 1.97 mm, respectively. Although geometric distortion along the phase encoding axis near the isocenter was small, the distortion increased slightly toward the peripheral regions. The distortion of the phase encoding direction in the peripheral region can be severely affected by the imaging gradient’s nonlinearity.
引用
收藏
页码:2068 / 2072
页数:4
相关论文
共 50 条
  • [1] Evaluation of Spatial-encoding-related Geometric Distortion in Magnetic Resonance Imaging
    Hong, Cheol Pyo
    Lee, Dong Hoon
    Lee, Man Woo
    Woo, Youngkeun
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2012, 61 (12) : 2068 - 2072
  • [2] Geometric Distortion in Structural Magnetic Resonance Imaging
    Wang, Deming
    Doddrell, David M.
    CURRENT MEDICAL IMAGING REVIEWS, 2005, 1 (01) : 49 - 60
  • [3] Audit feasibility for geometric distortion in magnetic resonance imaging for radiotherapy
    Alzahrani, Meshal
    Broadbent, David A.
    Chuter, Robert
    Al-Qaisieh, Bashar
    Jackson, Steven
    Michael, Hutton
    Johnstone, Robert, I
    Shah, Simon
    Wetscherek, Andreas
    Chick, H. Joan
    Wyatt, Jonathan J.
    McCallum, Hazel Mhairi
    Speight, Richard
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2020, 15 : 80 - 84
  • [4] A detailed study on the use of polynomial functions for modeling geometric distortion in magnetic resonance imaging
    Wang, Deming
    Yang, Zhengyi
    MEDICAL PHYSICS, 2008, 35 (03) : 908 - 916
  • [5] Image Quality and Geometric Distortion of Modern Diffusion-Weighted Imaging Sequences in Magnetic Resonance Imaging of the Prostate
    Stocker, Daniel
    Manoliu, Andrei
    Becker, Anton S.
    Barth, Borna K.
    Nanz, Daniel
    Klarhofer, Markus
    Donati, Olivio F.
    INVESTIGATIVE RADIOLOGY, 2018, 53 (04) : 200 - 206
  • [6] Evaluation of system-related magnetic resonance imaging geometric distortion in radiation therapy treatment planning: two approaches and effectiveness of three-dimensional distortion correction
    Kato, Yutaka
    Okudaira, Kuniyasu
    Kamomae, Takeshi
    Kumagai, Motoki
    Nagai, Youta
    Taoka, Toshiaki
    Itoh, Yoshiyuki
    Naganawa, Shinji
    NAGOYA JOURNAL OF MEDICAL SCIENCE, 2022, 84 (01): : 29 - 41
  • [7] Use of nonlinear pulsed magnetic fields for spatial encoding in magnetic resonance imaging
    Tusar, Kaja
    Sersa, Igor
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [8] An Anthropomorphic Head Phantom Prototype for the Measurement of Geometric Distortion in Magnetic Resonance Imaging System
    Shurche, Sadegh
    Sooteh, Mohammad Yousefi
    Iranian Journal of Medical Physics, 2024, 21 (01) : 53 - 63
  • [9] ON THE PROBLEM OF GEOMETRIC DISTORTION IN MAGNETIC-RESONANCE IMAGES FOR STEREOTAXIC NEUROSURGERY
    MICHIELS, J
    BOSMANS, H
    PELGRIMS, P
    VANDERMEULEN, D
    GYBELS, J
    MARCHAL, G
    SUETENS, P
    MAGNETIC RESONANCE IMAGING, 1994, 12 (05) : 749 - 765
  • [10] Impact of magnetic resonance imaging-related geometric distortion of dose distribution in fractionated stereotactic radiotherapy in patients with brain metastases
    Ohira, Shingo
    Suzuki, Yuta
    Washio, Hayate
    Yamamoto, Yuki
    Tateishi, Soichiro
    Inui, Shoki
    Kanayama, Naoyuki
    Kawamata, Minoru
    Miyazaki, Masayoshi
    Nishio, Teiji
    Koizumi, Masahiko
    Nakanishi, Katsuyuki
    Konishi, Koji
    STRAHLENTHERAPIE UND ONKOLOGIE, 2024, 200 (01) : 39 - 48