Deviations of Capacitive and Inductive Loops in the Electrochemical Impedance of a Dissolving Iron Electrode

被引:0
作者
Masayuki Itagaki
Akihiro Taya
Kunihiro Watanabe
Kazuhiko Noda
机构
[1] Tokyo University of Science,Department of Pure and Applied Chemistry, Faculty of Science and Technology
[2] National Institute for Materials Science,Corrosion Research Group
[3] Sengen,undefined
[4] Tsukuba,undefined
来源
Analytical Sciences | 2002年 / 18卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
The electrochemical impedance of an iron electrode often shows the capacitive and inductive loops on the complex plane. The capacitive loop originates from the time constant of the charge transfer resistance and the electric double layer capacitance. The inductive loop is explained by Faradaic processes involving the reaction intermediate. In some cases, these loops deviate from a true semicircle. In this paper, the origins and curve-fitting methods for the deviated loops of electrochemical impedance are discussed. The constant phase element (CPE) was used to present the deviation of the capacitive loop instead of electric double layer capacitance. The reaction rate constants, which are a function of the frequency, are proposed for the Faradaic impedance to present the deviated inductive loop.
引用
收藏
页码:641 / 644
页数:3
相关论文
共 50 条
[41]   Two-Frequency Criterion of the Presence of Inductive Component in the Electrochemical Cell Impedance [J].
Sekushin, N. A. .
RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2010, 46 (03) :345-353
[42]   CORROSION RATE ESTIMATION FROM PSEUDO-INDUCTIVE ELECTROCHEMICAL IMPEDANCE RESPONSE [J].
SILVERMAN, DC .
CORROSION, 1989, 45 (10) :824-830
[43]   Two-frequency criterion of the presence of inductive component in the electrochemical cell impedance [J].
N. A. Sekushin .
Russian Journal of Electrochemistry, 2010, 46 :345-353
[44]   From theory to practice: Unlocking the distribution of capacitive times in electrochemical impedance spectroscopy [J].
Py, Baptiste ;
Maradesa, Adeleke ;
Ciucci, Francesco .
ELECTROCHIMICA ACTA, 2024, 479
[45]   Flow electrode capacitive deionization with iron-based redox electrolyte [J].
Freire, Nelson H. J. ;
Linnartz, Christian J. ;
Montoro, Luciano A. ;
Ciminelli, Virginia S. T. ;
Wessling, Matthias .
DESALINATION, 2024, 578
[46]   IMPEDANCE CHARACTERISTICS OF MICROSTRIP ANTENNAS EXCITED BY COPLANAR WAVE-GUIDES WITH INDUCTIVE OR CAPACITIVE COUPLING SLOTS [J].
DENG, SM ;
WU, MD ;
HSU, PW .
IEEE MICROWAVE AND GUIDED WAVE LETTERS, 1995, 5 (11) :391-393
[47]   Deconvolution of electrochemical impedance data for the monitoring of electrode degradation in VRFB [J].
Schneider, Jonathan ;
Tichter, Tim ;
Khadke, Prashant ;
Zeis, Roswitha ;
Roth, Christina .
ELECTROCHIMICA ACTA, 2020, 336
[48]   Determination of electrochemical impedance for electrode reaction without time stability [J].
Itagaki, M ;
Taya, A ;
Watanabe, K .
ELECTROCHEMISTRY, 2000, 68 (07) :596-601
[49]   Electrochemical impedance spectroscopy of patterned steady states on electrode surfaces [J].
Bonnefont, Antoine ;
Morschl, Richard ;
Bauer, Philipp ;
Krischer, Katharina .
ELECTROCHIMICA ACTA, 2009, 55 (02) :410-415
[50]   ELECTROCHEMICAL STUDY OF ELECTRODE BEHAVIOR DURING BIOELECTRIC IMPEDANCE MEASUREMENTS [J].
GEORGES, B ;
PEGOFF, S ;
RYBOWSKI, L ;
WINAND, R ;
FONTANA, A ;
DIERICKX, M ;
HINSENKAMP, M ;
BURNY, F .
ACTA ORTHOPAEDICA SCANDINAVICA, 1982, 53 :9-14