Deviations of Capacitive and Inductive Loops in the Electrochemical Impedance of a Dissolving Iron Electrode

被引:0
作者
Masayuki Itagaki
Akihiro Taya
Kunihiro Watanabe
Kazuhiko Noda
机构
[1] Tokyo University of Science,Department of Pure and Applied Chemistry, Faculty of Science and Technology
[2] National Institute for Materials Science,Corrosion Research Group
[3] Sengen,undefined
[4] Tsukuba,undefined
来源
Analytical Sciences | 2002年 / 18卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
The electrochemical impedance of an iron electrode often shows the capacitive and inductive loops on the complex plane. The capacitive loop originates from the time constant of the charge transfer resistance and the electric double layer capacitance. The inductive loop is explained by Faradaic processes involving the reaction intermediate. In some cases, these loops deviate from a true semicircle. In this paper, the origins and curve-fitting methods for the deviated loops of electrochemical impedance are discussed. The constant phase element (CPE) was used to present the deviation of the capacitive loop instead of electric double layer capacitance. The reaction rate constants, which are a function of the frequency, are proposed for the Faradaic impedance to present the deviated inductive loop.
引用
收藏
页码:641 / 644
页数:3
相关论文
共 50 条
  • [21] A Novel Reconfigurable Impedance Matching Network Using Tunable MEMS Capacitive and Inductive Components
    Fall, Elhadji Mansour
    Domingue, Frederic
    Fouladi, Siamak
    Mansour, Raafat R.
    2011 6TH EUROPEAN MICROWAVE INTEGRATED CIRCUIT CONFERENCE, 2011, : 664 - 667
  • [22] Negative Impedance Capacitive Electrode for ECG Sensing Through Fabric Layer
    Wang, Ting-Wei
    Lin, Shien-Fong
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [23] ELECTRODE IMPEDANCE OF IRON IN A BORATE BUFFER SOLUTION
    GILES, RD
    HAMPSON, NA
    MARSHALL, A
    LATHAM, RJ
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1973, 47 (03): : 535 - 538
  • [24] Electrochemical behavior of iron in acetonitrile investigated by electrochemical impedance spectroscopy
    Itagaki, M
    Shimoda, K
    Watanabe, K
    ELECTROCHEMISTRY, 2002, 70 (08) : 595 - 601
  • [25] Method Comparison for Deconvoluting Capacitive and Pseudo-Capacitive Contributions to Electrochemical Capacitor Electrode Behavior
    Forghani, Marveh
    Donne, Scott W.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2018, 165 (03) : A664 - A673
  • [26] Probing electrode structure using electrochemical impedance spectroscopy
    Murthy, M
    PROTON CONDUCTING MEMBRANE FUEL CELLS III, PROCEEDINGS, 2005, 2002 (31): : 257 - 269
  • [27] Electrochemical Impedance of a Battery Electrode with Anisotropic Active Particles
    Song, Juhyun
    Bazant, Martin Z.
    ELECTROCHIMICA ACTA, 2014, 131 : 214 - 227
  • [28] Electrochemical impedance spectroscopy: Understanding the role of the reference electrode
    Gomez-Camer, Juan Luis
    Novak, Petr
    ELECTROCHEMISTRY COMMUNICATIONS, 2013, 34 : 208 - 210
  • [29] Electrochemical impedance spectra study of the hydrogen storage electrode
    Yang, HB
    Zhang, YS
    Zhou, ZX
    Wei, JP
    Wang, GS
    Song, DY
    Cao, XJ
    Wang, CM
    JOURNAL OF ALLOYS AND COMPOUNDS, 1995, 231 (1-2) : 625 - 630
  • [30] Electrochemical impedance measurement of a carbon nanotube probe electrode
    Inaba, Akira
    Takei, Yusuke
    Kan, Tetsuo
    Matsumoto, Kiyoshi
    Shimoyama, Isao
    NANOTECHNOLOGY, 2012, 23 (48)