Optimized 25-hydroxyvitamin D analysis using liquid–liquid extraction with 2D separation with LC/MS/MS detection, provides superior precision compared to conventional assays

被引:0
作者
Michael W. Clarke
Robert C. Tuckey
Shelley Gorman
Barbara Holt
Prue H. Hart
机构
[1] UWA Centre for Metabolomics,
[2] Metabolomics Australia,undefined
[3] University of Western Australia,undefined
[4] School of Chemistry and Biochemistry,undefined
[5] University of Western Australia,undefined
[6] Telethon Institute for Child Health Research,undefined
[7] Centre for Child Health Research,undefined
[8] University of Western Australia,undefined
来源
Metabolomics | 2013年 / 9卷
关键词
Vitamin D; Mass spectrometry; Epimer; DEQAS; Pediatric samples;
D O I
暂无
中图分类号
学科分类号
摘要
The analysis of 25-hydroxyvitamin D3 (25(OH)D3) and related metabolites represents a considerable challenge for both clinical and research laboratories worldwide. There is currently debate about the best methodology employed to assess vitamin D status and whether the 3-epi-25-hydroxyvitamin D3 (3-epi-25(OH)D3) should be separated and quantitated when measuring 25(OH)D3. Mass spectrometry techniques are generally regarded as the gold standard due to high specificity for vitamin D metabolites. However, many methods require high sample volumes for analysis. We have developed a new 2 dimensional (2D) ultra performance liquid chromatography (UPLC) separation coupled tandem mass spectrometry (MS/MS) detection to accurately quantitate 25(OH)D3, epi-25(OH)D3, and 25(OH)D2 in adults and children, requiring only 50 μL of human serum. The assay gives excellent separation of epi-25(OH)D3, and 25(OH)D2 from 25(OH)D3, has excellent precision with an intra-assay CV of 0.5 % at 74 nmol/L and can report down to 2 nmol/L for 25(OH)D3. Furthermore, the method shows excellent agreement with the vitamin D external quality assessment scheme (DEQAS) quality control program for vitamin D analysis. We present this approach as a candidate reference method for 25(OH)D3, epi-25(OH)D3, and 25(OH)D2 analysis in humans.
引用
收藏
页码:1031 / 1040
页数:9
相关论文
共 35 条
  • [1] Optimized 25-hydroxyvitamin D analysis using liquid-liquid extraction with 2D separation with LC/MS/MS detection, provides superior precision compared to conventional assays
    Clarke, Michael W.
    Tuckey, Robert C.
    Gorman, Shelley
    Holt, Barbara
    Hart, Prue H.
    METABOLOMICS, 2013, 9 (05) : 1031 - 1040
  • [2] Four years of LC-MS/MS method for quantification of 25-hydroxyvitamin D (D2+D3) for clinical practice
    Meunier, Cecile
    Monteremal, Julien
    Faure, Patrice
    Ducros, Veronique
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 989 : 54 - 61
  • [3] Analysis of vitamin D3-sulfate and 25-hydroxyvitamin D3-sulfate in breastmilk by LC-MS/MS
    Reynolds, Carmen J.
    Vizenor, Brady A.
    Koszewski, Nicholas J.
    Singh, Ravinder J.
    Thacher, Tom D.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2024, 1232
  • [4] A simple micro-extraction plate assay for automated LC-MS/MS analysis of human serum 25-hydroxyvitamin D levels
    Geib, Timon
    Meier, Florian
    Schorr, Pascal
    Lammert, Frank
    Stokes, Caroline S.
    Volmer, Dietrich A.
    JOURNAL OF MASS SPECTROMETRY, 2015, 50 (01): : 275 - 279
  • [5] New approach for the clinical monitoring of 25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 by ultra high performance liquid chromatography with MS/MS based on the standard reference material 972
    Plisek, Jiri
    Krcmova, Lenka Kujovska
    Aufartova, Jana
    Morales, Tanausu V.
    Esponda, Sarah M.
    Oros, Roman
    Kasalova, Eva
    Santana-Rodriguez, Jose J.
    Sobotka, Lubos
    Solich, Petr
    Solichova, Dagmar
    JOURNAL OF SEPARATION SCIENCE, 2013, 36 (23) : 3702 - 3708
  • [6] Enhanced 3-epi-25-hydroxyvitamin D3 signal leads to overestimation of its concentration and amplifies interference in 25-hydroxyvitamin D LC-MS/MS assays
    Flynn, N.
    Lam, F.
    Dawnay, A.
    ANNALS OF CLINICAL BIOCHEMISTRY, 2014, 51 (03) : 352 - 359
  • [7] Overestimation of 25-hydroxyvitamin D3 by increased ionisation efficiency of 3-epi-25-hydroxyvitamin D3 in LC-MS/MS methods not separating both metabolites as determined by an LC-MS/MS method for separate quantification of 25-hydroxyvitamin D3, 3-epi-25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 in human serum
    van den Ouweland, Johannes M. W.
    Beijers, Antonius M.
    van Daal, Henny
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 967 : 195 - 202
  • [8] Quantitation of 25-hydroxyvitamin D in dried blood spots by 2D LC-MS/MS without derivatization and correlation with serum in adult and pediatric studies
    Jensen, Bent P.
    Saraf, Rajneeta
    Ma, Jing
    Berry, Sarah
    Grant, Cameron C.
    Camargo, Carlos A., Jr.
    Sies, Christiaan W.
    CLINICA CHIMICA ACTA, 2018, 481 : 61 - 68
  • [9] Development and optimization of an LC-MS/MS-based method for simultaneous quantification of vitamin D2, vitamin D3, 25-hydroxyvitamin D2 and 25-hydroxyvitamin D3
    Adamec, Jiri
    Jannasch, Amber
    Huang, Jianjie
    Hohman, Emily
    Fleet, James C.
    Peacock, Munro
    Ferruzzi, Mario G.
    Martin, Berdine
    Weaver, Connie M.
    JOURNAL OF SEPARATION SCIENCE, 2011, 34 (01) : 11 - 20
  • [10] High-throughput measurement of 25-hydroxyvitamin D by LC-MS/MS with separation of the C3-epimer interference for pediatric populations
    Yang, Yifei
    Rogers, Katherine
    Wardle, Robert
    El-Khoury, Joe M.
    CLINICA CHIMICA ACTA, 2016, 454 : 102 - 106