Intra-arterial haemodynamic changes during cerebral three-dimensional rotational angiography

被引:0
|
作者
Peter Waldenberger
Andreas Chemelli
Ammar Mallouhi
机构
[1] St. Vincent Hospital,Department of Radiology
[2] Innsbruck Medical University,Department of Radiology I
[3] Innsbruck Medical University,Department of Radiology II
来源
European Radiology | 2009年 / 19卷
关键词
Three-dimensional rotational angiography; Intra-arterial pressure; Subarachnoid haemorrhage; Cerebral aneurysm; Aneurysm rupture;
D O I
暂无
中图分类号
学科分类号
摘要
Three-dimensional rotational angiography (3DRA) is useful for detecting, classifying and planning treatment for intracranial aneurysms. Prolonged contrast material (CM) injection, required for 3DRA, might cause blood pressure changes in the selectively catheterized artery. The purpose of this study was to assess the extent and clinical relevance of haemodynamic changes in the selected artery during 3DRA. Twenty-five consecutive patients with intracranial aneurysms were prospectively examined with 3DRA (18 ml, 3 ml/s power injector) for planning treatment. Intra-arterial pressure was measured in the internal carotid or vertebral artery by using a pressure guidewire. Mean and systolic blood pressure acquired by the guidewire (Pd) and fractional flow reserve (FFR) were measured before, during and after CM injection. The extent of Pd and FFR changes was evaluated by Student’s t-test and linear regression analysis and their clinical relevance with the limits-of-agreement analysis. Mean systolic Pd and FFR increased significantly (P < 0.001) from 105.2 ± 22 mmHg and 0.98 ± 0.04, respectively, at the baseline to 118.1 ± 23 mmHg and 1.09 ± 0.12, respectively, during injection and decreased thereafter to baseline. The correlation between mean and systolic Pd during injection and at baseline was moderate (r2 = 0.47 and 0.63, respectively) but remained significant (P = 0.001 and <0.001, respectively). Moderate bias and range of agreement were found for systolic Pd (12.8 ± 29.2 mmHg) and FFR (0.1 ± 0.24). Selective CM injection during 3DRA causes a temporary but clinically tolerable increase in blood pressure and pressure gradient.
引用
收藏
页码:503 / 508
页数:5
相关论文
共 50 条
  • [1] Intra-arterial haemodynamic changes during cerebral three-dimensional rotational angiography
    Waldenberger, Peter
    Chemelli, Andreas
    Mallouhi, Ammar
    EUROPEAN RADIOLOGY, 2009, 19 (02) : 503 - 508
  • [2] INTEGRATION OF THREE-DIMENSIONAL ROTATIONAL ANGIOGRAPHY IN RADIOSURGICAL TREATMENT PLANNING OF CEREBRAL ARTERIOVENOUS MALFORMATIONS
    Conti, Alfredo
    Pontoriero, Antonio
    Farago, Giuseppe
    Midili, Federica
    Siragusa, Carmelo
    Granata, Francesca
    Pitrone, Antonio
    De Renzis, Costantino
    Longo, Marcello
    Tomasello, Francesco
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (03): : E29 - E37
  • [3] Three-dimensional rotational angiography guidance for aneurysm surgery
    Raabe, Andreas
    Beck, Juergen
    Rohde, Stefan
    Berkefeld, Joachim
    Seifert, Volker
    JOURNAL OF NEUROSURGERY, 2006, 105 (03) : 406 - 411
  • [4] Computed Tomography Angiography with Three-Dimensional Reconstruction versus Rotational Angiography as a Screening Test in Patients with Suspected Cerebral Aneurysm
    Zarate Mendez, Antonio Maximiano
    Pena Rosas, Nadia Perez
    Lujan Guerra, Juan Carlos
    Garcia Mayagoitia, Antonio
    Betanzos Villegas, Aleixandre
    Lizararu Gutierrez, Eduardo Walter
    Cachon Camara, Gabriel Emmanuel
    Olvera Castro, Jorge Octavio
    Aceves Chimal, Jose Luis
    INDIAN JOURNAL OF NEUROSURGERY, 2016, 5 (02) : 95 - 100
  • [5] Cerebral aneurysms diagnosis by three-dimensional CT angiography
    de Andrade, GC
    Teixeira, PAD
    Alves, HFP
    Donato, EE
    Moreira, CAA
    de Faria, RCS
    Dias, LAA
    ARQUIVOS DE NEURO-PSIQUIATRIA, 2003, 61 (01) : 74 - 78
  • [6] Utility of intra-arterial nimodipine for cerebral vasospasm
    Nathal, E.
    Garcia-Perales, C.
    Lee, A.
    Ondarza, R.
    Zenteno, M.
    CEREBRAL VASOSPASM: NEW STRATEGIES IN RESEARCH AND TREATMENT, 2008, 104 : 353 - +
  • [7] Percutaneous pulmonary valve implantation guided by three-dimensional rotational angiography
    Krings, Gregor J.
    Driesen, Bart W.
    Warmerdam, Evangeline G.
    Molenschot, Mirella C.
    Sieswerda, Gert-Jan T.
    Doevendans, Pieter A.
    van Dijk, Arie P. J.
    Voskuil, M.
    INTERNATIONAL JOURNAL OF CARDIOLOGY CONGENITAL HEART DISEASE, 2024, 18
  • [8] 256-row multislice CT angiography in the postoperative evaluation of cerebral aneurysms treated with titanium clips: using three-dimensional rotational angiography as the standard of reference
    Kim, Hye Jeong
    Yoon, Dae Young
    Kim, Eun Soo
    Yun, Eun Joo
    Jeon, Hong Jun
    Lee, Jong Young
    Cho, Byung-Moon
    EUROPEAN RADIOLOGY, 2020, 30 (04) : 2152 - 2160
  • [9] 256-row multislice CT angiography in the postoperative evaluation of cerebral aneurysms treated with titanium clips: using three-dimensional rotational angiography as the standard of reference
    Hye Jeong Kim
    Dae Young Yoon
    Eun Soo Kim
    Eun Joo Yun
    Hong Jun Jeon
    Jong Young Lee
    Byung-Moon Cho
    European Radiology, 2020, 30 : 2152 - 2160
  • [10] Diagnostic Utility of Three-Dimensional Rotational Angiography in Congenital Cardiac Catheterization
    Aldoss, Osamah
    Fonseca, Brian M.
    Truong, Uyen T.
    Bracken, John
    Darst, Jeffrey R.
    Guo, Ruixin
    Jones, Tamekia L.
    Fagan, Thomas E.
    PEDIATRIC CARDIOLOGY, 2016, 37 (07) : 1211 - 1221