Post-polymerization photografting on methacrylate-based monoliths for separation of intact proteins and protein digests with comprehensive two-dimensional liquid chromatography hyphenated with high-resolution mass spectrometry

被引:0
作者
Rudy J. Vonk
Sam Wouters
Andrei Barcaru
Gabriel Vivó-Truyols
Sebastiaan Eeltink
Leo J. de Koning
Peter J. Schoenmakers
机构
[1] University of Amsterdam,Analytical
[2] Vrije Universiteit Brussel,Chemistry Group, van’t Hoff Institute for Molecular Sciences
[3] University of Amsterdam,Department of Chemical Engineering
来源
Analytical and Bioanalytical Chemistry | 2015年 / 407卷
关键词
Photografting; Organic monoliths; Experimental design; Two-dimensional separation; Ion-exchange chromatography;
D O I
暂无
中图分类号
学科分类号
摘要
Post-polymerization photografting is a versatile tool to alter the surface chemistry of organic-based monoliths so as to obtain desired stationary phase properties. In this study, 2-acrylamido-2-methyl-1-propanesulfonic acid was grafted to a hydrophobic poly(butyl methacrylate-co-ethylene glycol dimethacrylate) monolith to create a strong cation exchange stationary phase. Both single-step and two-step photografting were addressed, and the effects of grafting conditions were assessed. An experimental design has been applied in an attempt to optimize three of the key parameters of the two-step photografting chemistry, i.e. the grafting time of the initiator, the monomer concentration and the monomer irradiation time. The photografted columns were implemented in a comprehensive two-dimensional column liquid chromatography (tLC × tLC) workflow and applied for the separation of intact proteins and peptides. A baseline separation of 11 intact proteins was obtained within 20 min by implementing a gradient across a limited RP composition window in the second dimension. tLC × tLC with UV detection was used for the separation of cytochrome c digest, bovine serum insulin digest and a digest of a complex protein mixture. A semi-quantitative estimation of the occupation of separation space, the orthogonality, of the tLC × tLC system yielded 75 %. The tLC × tLC setup was hyphenated to a high-resolution Fourier transform ion cyclotron resonance mass spectrometer instrument to identify the bovine serum insulin tryptic peptides and to demonstrate the compatibility with MS analysis.
引用
收藏
页码:3817 / 3829
页数:12
相关论文
共 141 条
[1]  
Han YH(2010)Monolithic superhydrophobic polymer layer with photopatterned virtual channel for the separation of peptides using two-dimensional thin layer chromatography-desorption electrospray ionization mass spectrometry Anal Chem 82 2520-2528
[2]  
Levkin PA(2011)Construction and initial evaluation of an apparatus for spatial comprehensive two-dimensional liquid-phase separations Anal Chim Acta 701 92-97
[3]  
Abarientos I(1995)Sample dimensionality: a predictor of order-disorder in component peak distribution in multidimensional separation J Chromatogr A 703 3-15
[4]  
Liu HW(2006)A protocol for designing comprehensive two-dimensional liquid chromatography separation systems J Chromatogr A 1120 282-290
[5]  
Svec F(2001)An automated multidimensional protein identification technology for shotgun proteomics Anal Chem 73 5683-5690
[6]  
Fréchet JMJ(2004)Fully automated online multi-dimensional protein profiling system for complex mixtures J Chromatogr A 1057 107-113
[7]  
Vanhoutte DJD(2004)Grafting: a versatile means to modify polymers: techniques, factors and applications Prog Polym Sci 29 767-814
[8]  
Eeltink S(1957)Graft copolymer of polyacrylamide and natural rubber produced by means of ultraviolet light J Polym Sci 26 233-234
[9]  
Kok WT(2003)Photografting and the control of surface chemistry in three-dimensional porous polymer monoliths Macromolecules 36 1677-1684
[10]  
Schoenmakers PJ(2006)Patternable protein resistant surfaces for multifunctional microfluidic devices via surface hydrophilization of porous polymer monoliths using photografting Chem Mater 18 5950-5957