A pilot-scale forward osmosis membrane system for concentrating low-strength municipal wastewater: performance and implications

被引:0
|
作者
Zhiwei Wang
Junjian Zheng
Jixu Tang
Xinhua Wang
Zhichao Wu
机构
[1] State Key Laboratory of Pollution Control and Resource Reuse,
[2] School of Environmental Science and Engineering,undefined
[3] Tongji University,undefined
[4] School of Environmental and Civil Engineering,undefined
[5] Jiangnan University,undefined
来源
Scientific Reports | / 6卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Recovery of nutrients and energy from municipal wastewater has attracted much attention in recent years; however, its efficiency is significantly limited by the low-strength properties of municipal wastewater. Herein, we report a pilot-scale forward osmosis (FO) system using a spiral-wound membrane module to concentrate real municipal wastewater. Under active layer facing feed solution mode, the critical concentration factor (CCF) of this FO system was determined to be 8 with 0.5 M NaCl as draw solution. During long-term operation at a concentration factor of 5, (99.8 ± 0.6)% of chemical oxygen demand and (99.7 ± 0.5)% of total phosphorus rejection rates could be achieved at a flux of 6 L/(m2 h) on average. In comparison, only (48.1 ± 10.5)% and (67.8 ± 7.3)% rejection of ammonium and total nitrogen were observed. Cake enhanced concentration polarization is a major contributor to the decrease of water fluxes. The fouling also led to the occurrence of a cake reduced concentration polarization effect, improving ammonium rejection rate with the increase of operation time in each cycle. This work demonstrates the applicability of using FO process for wastewater concentrating and also limitations in ammonium recovery that need further improvement in future.
引用
收藏
相关论文
共 50 条
  • [1] A pilot-scale forward osmosis membrane system for concentrating low-strength municipal wastewater: performance and implications
    Wang, Zhiwei
    Zheng, Junjian
    Tang, Jixu
    Wang, Xinhua
    Wu, Zhichao
    SCIENTIFIC REPORTS, 2016, 6
  • [2] Impact of temperature on the performance and fouling behavior of a forward osmosis membrane system for concentrating low-strength sewage
    Anh-Vu, Nguyen
    Nomura, Youhei
    Hidaka, Taira
    Fujiwara, Taku
    JOURNAL OF WATER PROCESS ENGINEERING, 2025, 70
  • [3] Performance of a submerged anaerobic membrane bioreactor with forward osmosis membrane for low-strength wastewater treatment
    Chen, Lin
    Gu, Yangshuo
    Cao, Chuqing
    Zhang, Jun
    Ng, Jing-Wen
    Tang, Chuyang
    WATER RESEARCH, 2014, 50 : 114 - 123
  • [4] Granulation of activated sludge in a pilot-scale sequencing batch reactor for the treatment of low-strength municipal wastewater
    Ni, Bing-Jie
    Xie, Wen-Ming
    Liu, Shao-Gen
    Yu, Han-Qing
    Wang, Ying-Zhe
    Wang, Gan
    Dai, Xian-Liang
    WATER RESEARCH, 2009, 43 (03) : 751 - 761
  • [5] Pilot-scale study of forward osmosis for treating desulfurization wastewater
    Ma, Cong
    Li, Qianqian
    Dai, Chang
    Wang, Liang
    Zhao, Bin
    Zhang, Zhaohui
    Xue, Siguo
    Tian, Wende
    WATER SCIENCE AND TECHNOLOGY, 2020, 82 (12) : 2857 - 2863
  • [6] Performance and fouling characteristics in a pilot-scale reverse osmosis membrane system for microelectronic wastewater treatment
    Li, Xianfeng
    Lin, Ling
    Zhang, Xiaoxin
    Dai, Ruobin
    Wu, Zhichao
    Wang, Zhiwei
    SEPARATION AND PURIFICATION TECHNOLOGY, 2024, 337
  • [7] Effects of Hydraulic Retention Time (HRT) on the Performance of a Pilot-Scale Trickling Filter System Treating Low-Strength Domestic Wastewater
    Rehman, Abdul
    Ayub, Nasir
    Naz, Iffat
    Perveen, Irum
    Ahmed, Safia
    POLISH JOURNAL OF ENVIRONMENTAL STUDIES, 2020, 29 (01): : 249 - 259
  • [8] Pilot-scale experiment of down-flow hanging sponge for direct treatment of low-strength municipal wastewater in Bangkok, Thailand
    Onodera, Takashi
    Yoochatchaval, Wilasinee
    Sumino, Haruhiko
    Mizuochi, Motoyuki
    Okadera, Tomohiro
    Fujita, Tsuyoshi
    Banjongproo, Pathan
    Syutsubo, Kazuaki
    BIOPROCESS AND BIOSYSTEMS ENGINEERING, 2014, 37 (11) : 2281 - 2287
  • [9] Pilot-scale experiment of down-flow hanging sponge for direct treatment of low-strength municipal wastewater in Bangkok, Thailand
    Takashi Onodera
    Wilasinee Yoochatchaval
    Haruhiko Sumino
    Motoyuki Mizuochi
    Tomohiro Okadera
    Tsuyoshi Fujita
    Pathan Banjongproo
    Kazuaki Syutsubo
    Bioprocess and Biosystems Engineering, 2014, 37 : 2281 - 2287
  • [10] Pilot-scale continuous flow granular reactor for the treatment of extremely low-strength recirculating aquaculture system wastewater
    Santorio, S.
    del Rio, A. Val
    Amorim, C. L.
    Arregui, L.
    Castro, P. M. L.
    Mosquera-Corral, A.
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2022, 10 (02):