Measurement of tracheal temperature is not a reliable index of total respiratory heat loss in mechanically ventilated patients

被引:0
|
作者
Thomachot L. [1 ]
Viviand X. [1 ]
Lagier P. [1 ]
Dejode J.M. [1 ]
Albanèse J. [1 ]
Martin C. [1 ]
机构
[1] Departement d'Anesthesie-Reanimation, Hôpital Nord
来源
Critical Care | / 5卷 / 1期
关键词
Humidification of inspired gases; Mechanical ventilation; Total respiratory heat loss; Tracheal temperature;
D O I
10.1186/cc974
中图分类号
学科分类号
摘要
Background: Minimizing total respiratory heat loss is an important goal during mechanical ventilation. The aim of the present study was to evaluate whether changes in tracheal temperature (a clinical parameter that is easy to measure) are reliable indices of total respiratory heat loss in mechanically ventilated patients. Method: Total respiratory heat loss was measured, with three different methods of inspired gas conditioning, in 10 sedated patients. The study was randomized and of a crossover design. Each patient was ventilated for three consecutive 24-h periods with a heated humidifier (HH), a hydrophobic heat-moisture exchanger (HME) and a hygroscopic HME. Total respiratory heat loss and tracheal temperature were simultaneously obtained in each patient. Measurements were obtained during each 24-h study period after 45 min, and 6 and 24 h. Results: Total respiratory heat loss varied from 51 to 52cal/min with the HH, from 100 to 108cal/min with the hydrophobic HME, and from 92 to 102cal/min with the hygroscopic HME (P<0.01). Simultaneous measurements of maximal tracheal temperatures revealed no significant differences between the HH (35.7-35.9°C) and either HME (hydrophobic 35.3-35.4°C, hygroscopic 36.2-36.3°C). Conclusion: In intensive care unit (ICU) mechanically ventilated patients, total respiratory heat loss was twice as much with either hydrophobic or hydroscopic HME than with the HH. This suggests that a much greater amount of heat was extracted from the respiratory tract by the HMEs than by the HH. Tracheal temperature, although simple to measure in ICU patients, does not appear to be a reliable estimate of total respiratory heat loss.
引用
收藏
页码:24 / 30
页数:6
相关论文
共 50 条
  • [22] Respiratory viruses in mechanically ventilated patients: a pilot study
    Raquel Nazareth
    Maria-Jesus Chasqueira
    Maria-Lúcia Rodrigues
    Carolina Paulino
    Catarina Conceição
    Lia Lêdo
    Úrsula Segura
    Madalena Santos
    António Messias
    Pedro Póvoa
    Paulo Paixão
    BMC Pulmonary Medicine, 20
  • [23] Diaphragm Thickness and Respiratory Drive in Mechanically Ventilated Patients
    Luoma, K.
    Owens, R. L.
    Malhotra, A.
    Orr, J. E.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2023, 207
  • [24] Respiratory muscle dysfunction in mechanically-ventilated patients
    Martin J. Tobin
    Franco Laghi
    Amal Jubran
    Molecular and Cellular Biochemistry, 1998, 179 : 87 - 98
  • [25] TOTAL PARENTERAL-NUTRITION INDUCES HYPERCAPNIA IN MECHANICALLY VENTILATED PATIENTS WITH CHRONIC RESPIRATORY INSUFFISIENCY
    HERVE, P
    SIMONNEAU, G
    GIRARD, P
    CERRINA, J
    MATHIEU, M
    DUROUX, P
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1983, 127 (04): : 255 - 255
  • [26] Respiratory microbiome in mechanically ventilated patients: a narrative review
    Fromentin, Melanie
    Ricard, Jean-Damien
    Roux, Damien
    INTENSIVE CARE MEDICINE, 2021, 47 (03) : 292 - 306
  • [27] Bispectral index variations during tracheal suction in mechanically ventilated critically ill patients: effect of an alfentanil bolus
    Elsa Brocas
    Hervé Dupont
    Catherine Paugam-Burtz
    Frédérique Servin
    Jean Mantz
    Jean-Marie Desmonts
    Intensive Care Medicine, 2002, 28 : 211 - 213
  • [28] Bispectral index variations during tracheal suction in mechanically ventilated critically ill patients: effect of an alfentanil bolus
    Brocas, E
    Dupont, H
    Paugam-Burtz, C
    Servin, F
    Mantz, J
    Desmonts, JM
    INTENSIVE CARE MEDICINE, 2002, 28 (02) : 211 - 213
  • [29] Effects of open and closed tracheal suctioning on pain in mechanically ventilated patients
    Khayer, Fatemeh
    Ghafari, Somayeh
    Saghaei, Mahmoud
    Yazdannik, Ahmadreza
    Atashi, Vajihe
    IRANIAN JOURNAL OF NURSING AND MIDWIFERY RESEARCH, 2020, 25 (05) : 426 - 430
  • [30] Resistance of laryngeal mask airway and tracheal tube in mechanically ventilated patients
    Reissmann, H
    Pothmann, W
    Füllekrug, B
    Dietz, R
    Schulte am Esch, J
    BRITISH JOURNAL OF ANAESTHESIA, 2000, 85 (03) : 410 - 416